Mitsubishi Electronics FR-A500L instruction manual Operation Panel Check Point Remedy Display

Page 42

 

 

 

 

 

PROTECTIVE FUNCTIONS

 

 

 

 

 

 

 

 

Operation Panel

 

 

Check Point

Remedy

 

Display

 

 

 

 

 

 

 

 

 

 

 

Is the usage frequency of the

Reduce the load GD2. Reduce the braking frequency.

 

 

Brake unit

brake unit appropriate?

Clean the cooling fins.

 

 

cooling fin

Are the cooling fins clogged?

 

 

overheating

Is there any error in the inverter

Replace the cooling fan.

 

 

 

unit cooling fan?

 

 

 

 

 

 

 

 

 

 

Control board

Is there an error in the cooling fan?

Replace the cooling fan.

 

 

ambient

Keep the ambient temperature within the

 

 

Is

the

ambient temperature too

 

 

temperature

specifications.

 

 

high?

 

 

 

error

 

 

 

 

 

 

 

 

 

 

 

Is there an output short circuit or

Repair the output short circuit and ground fault.

 

 

 

ground fault? (Check the motor

(Repair or replace the motor.)

 

 

 

winding and insulation resistance.)

Lengthen the deceleration time.

 

 

Output over

Was rapid acceleration attempted?

 

 

current

Did the load fluctuate suddenly?

Eliminate the sudden fluctuate in the load.

 

 

 

Was rapid deceleration attempted?

Lengthen the deceleration time.

 

 

 

Were the motor's mechanical

Investigate the braking operation.

 

 

 

brakes applied too quickly?

 

 

 

 

 

 

 

E.15

 

Is the cooling fan's power supply

Repair the short-circuited section.

 

 

Cooling fan

output short circuited?

 

 

 

power supply

Is the cooling fan's power supply

Replace the cooling fan power supply.

 

 

error

abnormal?

 

 

 

 

Is the fuse blown?

Replace the fuse.

 

 

 

 

 

 

 

 

Is the DC circuit short circuited?

Repair the short-circuited section, and replace the

 

 

Capacitor

 

 

 

DC fuse.

 

 

Is there an output short circuit or

Repair the output short circuit and ground fault.

 

 

overcurrent

ground fault? (Check the motor

(Repair or replace the motor.)

 

 

 

winding and insulation resistance.)

 

 

 

 

 

 

 

 

 

 

 

Is there an error in the cooling fan?

Replace the cooling fan.

 

 

 

Clean the cooling fins.

 

 

Cooling fin

Are the cooling fins clogged?

 

 

Keep the ambient temperature within the

 

 

overheat

Is the ambient temperature too

 

 

specifications.

 

 

 

high?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gate power

Is the gate output short circuited?

Repair the short-circuited section.

 

 

Replace the control power supply board.

 

 

Is

there

an error in the control

 

 

supply error

 

 

 

power supply board?

 

 

 

 

 

 

 

 

 

 

 

 

 

When the protective function is activated, take proper corrective action, reset the inverter, then resume operation.

31

Image 42
Contents FR-A560L-375K~900K-NA This section is specifically about safety matters Electric Shock Prevention Fire PreventionInjury Prevention Additional instructions Transportation and installationWiring Trial runEmergency stop Maintenance, inspection and parts replacementOperation Disposing of the inverterContents Chapter Outline Wiring Precautions for operationInstallation Pre-Operation InformationBasic Configuration Basic configurationName Description Chapter Installation Instructions for installationAt 5cm 1.97 inch Wiring Terminal connection diagramDescription of control circuit terminals Symbol Terminal Name DescriptionDescription of main circuit terminals Terminal Name DescriptionType Symbol Terminal Name Description Wiring of the main circuit Wiring instructionsTerminal block layout P1, P, N Connection procedure Wiring of the control circuit NA version(OR Version)Changing the control logic RUN DC24V How to use terminals STOP, CS and PC Connection to the PU connector For RS-485 communicationDesign information Chapter Operation Chapter Parameters Parameter List Parameters17, 18 R a M E T E R S 173 200 278 Protective Functions Errors Alarms Error alarm definitionsOHT Operatio Panel Unit Name Description Display FR-PU04 FR-DU04Main circuit error E,15 details Name DetailsTo know the operating status at the occurrence of alarm Correspondences between digital and actual charactersOperation Panel Output Terminal Signal On-Off Display Alarm code outputResetting the inverter Alarm Code Alarm Output across B-C (FR-DU04 )Troubleshooting Checking the operation panel display at alarm stopOperation Check Point Remedy Panel Display Operation Panel Check Point Remedy Display Motor remains stopped Faults and check pointsSpeed greatly differs from the setting Motor rotates in opposite directionMotor current is large Operation mode is not changed properlyPower lamp is not lit Speed does not increaseCheck items Precautions for Maintenance and InspectionPrecautions for maintenance and inspection Periodic inspectionInsulation resistance test using megger Dielectric strength testDaily and Periodic Inspection Preparation Checking methodModule device numbers and terminals to be checked Cooling fan Replacement of partsPart Name Standard Replacement Description Interval Smoothing capacitorsMeasurement of main circuit voltages, currents and power Measurement of voltages and currentsMeasuring Points and Instruments Chapter Specifications Standard specification Model specificationsCommon specifications Temperature applicable for a short period in transit, etc FR-A560L-450K, 375K Outline drawingsFR-A560L-530K~900K Specifications Appendices Appendix AppendixWiring between cooling fan and terminals is as follows Check the air flow directionAppendix Shipment case example Mitsubishi Electric Corporation