Mitsubishi Electronics FR-A500L instruction manual Specifications

Page 58

SPECIFICATIONS

46

Image 58
Contents FR-A560L-375K~900K-NA This section is specifically about safety matters Fire Prevention Electric Shock PreventionInjury Prevention Additional instructions Transportation and installationWiring Trial runEmergency stop Maintenance, inspection and parts replacementOperation Disposing of the inverterContents Chapter Outline Wiring Precautions for operationInstallation Pre-Operation InformationBasic configuration Basic ConfigurationName Description Chapter Installation Instructions for installationAt 5cm 1.97 inch Wiring Terminal connection diagramDescription of control circuit terminals Symbol Terminal Name DescriptionDescription of main circuit terminals Terminal Name DescriptionType Symbol Terminal Name Description Wiring of the main circuit Wiring instructionsTerminal block layout P1, P, N Connection procedure Wiring of the control circuit NA version(OR Version)Changing the control logic RUN DC24V How to use terminals STOP, CS and PC Connection to the PU connector For RS-485 communicationDesign information Chapter Operation Chapter Parameters Parameter List Parameters17, 18 R a M E T E R S 173 200 278 Protective Functions Errors Alarms Error alarm definitionsOHT Operatio Panel Unit Name Description Display FR-PU04 FR-DU04Main circuit error E,15 details Name DetailsTo know the operating status at the occurrence of alarm Correspondences between digital and actual charactersOperation Panel Output Terminal Signal On-Off Display Alarm code outputResetting the inverter Alarm Code Alarm Output across B-C (FR-DU04 )Checking the operation panel display at alarm stop TroubleshootingOperation Check Point Remedy Panel Display Operation Panel Check Point Remedy Display Motor remains stopped Faults and check pointsSpeed greatly differs from the setting Motor rotates in opposite directionMotor current is large Operation mode is not changed properlyPower lamp is not lit Speed does not increaseCheck items Precautions for Maintenance and InspectionPrecautions for maintenance and inspection Periodic inspectionInsulation resistance test using megger Dielectric strength testDaily and Periodic Inspection Checking method PreparationModule device numbers and terminals to be checked Cooling fan Replacement of partsPart Name Standard Replacement Description Interval Smoothing capacitorsMeasurement of main circuit voltages, currents and power Measurement of voltages and currentsMeasuring Points and Instruments Chapter Specifications Standard specification Model specificationsCommon specifications Temperature applicable for a short period in transit, etc FR-A560L-450K, 375K Outline drawingsFR-A560L-530K~900K Specifications Appendices Appendix AppendixWiring between cooling fan and terminals is as follows Check the air flow directionAppendix Shipment case example Mitsubishi Electric Corporation
Related manuals
Manual 63 pages 42.05 Kb