Mitsubishi Electronics FR-A500L instruction manual Standard specification, Model specifications

Page 53

6.1Standard specification

SPECIFICATIONS

6.1.1Model specifications

 

Model FR-A560L-□□□K-NA

375

450

530

 

600

670

 

750

800

 

900K

Applicable motor

Constant torque

375

450

530

 

600

670

 

750

800

 

900

capacity (kW) (Note 1)

Variable torque

450

530

600

 

670

750

 

800

900

 

950

 

Rated capacity (HP)

Constant torque

550

650

750

 

800

900

 

1000

1100

 

1200

 

(Note 2)

Variable torque

650

750

800

 

900

1000

 

1100

1200

 

1300

 

 

 

 

 

 

Rated current (A)

Constant torque

552

663

773

 

800

880

 

990

1100

 

1210

Output

Variable torque

663

773

800

 

880

990

 

1100

1210

 

1320

 

 

 

 

 

 

150% 60 sec., 200%

 

 

 

 

 

 

 

 

 

 

Constant torque

0.5 sec (inverse-time

 

 

150% 60 sec. (inverse-time characteristics)

 

 

 

 

 

 

 

Overload capacity

 

characteristics)

 

 

 

 

 

 

 

 

 

 

 

120% 60 sec., 150%

 

 

120% 60 sec. (inverse-time characteristics)

 

 

 

 

 

 

 

 

 

Variable torque

0.5 sec (inverse-time

 

 

 

 

 

 

characteristics)

 

 

 

 

 

 

 

 

 

 

Voltage

 

 

 

Three phase, 575V 5060Hz

 

 

 

 

 

 

 

 

 

 

 

 

 

supply

Rated input AC voltage, frequency

 

 

Three phase, 575V 5060Hz

 

 

 

Tolerable AC voltage fluctuation

 

 

 

488 to 632V 5060Hz

 

 

 

 

Tolerable frequency fluctuation

 

 

 

±5%

 

 

 

 

 

Power

 

 

 

 

 

 

 

 

Power facility

Constant torque

550

660

770

 

797

896

 

986

1095

 

1205

capacity (kVA)

Variable torque

660

770

797

 

896

986

 

1095

1205

 

1315

 

 

 

 

Protective structure (JEM 1030)

Open type (IP00)

 

 

 

Open type (IP20)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-10°C to 40°C

 

 

 

 

 

 

 

 

 

 

 

 

(14°F to 104°F) at

 

 

 

 

 

 

 

 

 

Ambient temperature

 

VT

 

-10°C to 40°C (14°F to 104°F)

 

 

 

 

 

-10°C to 50°C

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(14°F to 122°F) at

 

 

 

 

 

 

 

 

 

 

 

 

CT

 

 

 

 

 

 

 

 

 

 

Cooling method

 

 

 

 

 

Forced air cooling

 

 

 

 

Approx. weight (kg (lb) )

 

490

500

1060

 

1060

1100

 

1100

1200

 

1200

 

(1078)

(1100)

(2332)

 

(2332)

(2420)

 

(2420)

(2640)

 

(2640)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: 1. The applicable motor capacity indicated is the maximum capacity applicable when Mitsubishi 4-pole standard motor is used For A540K. (When National Electric Code based motor is used for A560L)

2.The rated output capacity indicated is based on National Electric Code for 460V for A540L. (575V for A560L)

3.The overload capacity indicated in % is the ratio of the overload current to the inverter’s rated current. For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.

4.The maximum output voltage cannot exceed the power supply voltage. The maximum output voltage may be set as desired below the power supply voltage.

5.The power supply capacity changes with the values of the power supply side inverter impedance (including those of the input reactor and cables).

6.For use in Variable torque mode, refer to Pr. 570.

7.For inverter environmental conditions (including ambient temperature) please check page A-3.

41

Image 53
Contents FR-A560L-375K~900K-NA This section is specifically about safety matters Injury Prevention Electric Shock PreventionFire Prevention Wiring Transportation and installationAdditional instructions Trial runOperation Maintenance, inspection and parts replacementEmergency stop Disposing of the inverterContents Chapter Outline Installation Precautions for operationWiring Pre-Operation InformationName Description Basic ConfigurationBasic configuration Chapter Instructions for installation InstallationAt 5cm 1.97 inch Terminal connection diagram WiringDescription of main circuit terminals Symbol Terminal Name DescriptionDescription of control circuit terminals Terminal Name DescriptionType Symbol Terminal Name Description Wiring instructions Wiring of the main circuitTerminal block layout P1, P, N Connection procedure NA version(OR Version) Wiring of the control circuitChanging the control logic RUN DC24V How to use terminals STOP, CS and PC For RS-485 communication Connection to the PU connectorDesign information Chapter Operation Chapter Parameters Parameters Parameter List17, 18 R a M E T E R S 173 200 278 Protective Functions Error alarm definitions Errors AlarmsOHT Panel Unit Name Description Display FR-PU04 FR-DU04 OperatioName Details Main circuit error E,15 detailsCorrespondences between digital and actual characters To know the operating status at the occurrence of alarmResetting the inverter Alarm code outputOperation Panel Output Terminal Signal On-Off Display Alarm Code Alarm Output across B-C (FR-DU04 )Operation Check Point Remedy Panel Display TroubleshootingChecking the operation panel display at alarm stop Operation Panel Check Point Remedy Display Speed greatly differs from the setting Faults and check pointsMotor remains stopped Motor rotates in opposite directionPower lamp is not lit Operation mode is not changed properlyMotor current is large Speed does not increasePrecautions for maintenance and inspection Precautions for Maintenance and InspectionCheck items Periodic inspectionDielectric strength test Insulation resistance test using meggerDaily and Periodic Inspection Module device numbers and terminals to be checked PreparationChecking method Part Name Standard Replacement Description Interval Replacement of partsCooling fan Smoothing capacitorsMeasurement of voltages and currents Measurement of main circuit voltages, currents and powerMeasuring Points and Instruments Chapter Specifications Model specifications Standard specificationCommon specifications Temperature applicable for a short period in transit, etc Outline drawings FR-A560L-450K, 375KFR-A560L-530K~900K Specifications Appendices Appendix AppendixCheck the air flow direction Wiring between cooling fan and terminals is as followsAppendix Shipment case example Mitsubishi Electric Corporation
Related manuals