Allied Air Enterprises 4HP16LT manual Operation, Filter Drier

Page 17

OPERATION

Outdoor unit and indoor blower cycle on demand from the room thermostat. When the thermostat blower switch is moved to the ON position, the indoor blower operates continuously.

Filter Drier

The unit is equipped with a large capacity bi-flow filter which keeps the system clean and dry. If replacement is necessary, replace with one of similar design and capacity. The replacement filter drier must be suitable for use with R410A refrigerant.

Crankcase Heater

If unit is equipped with a crankcase heater, it should be energized 24 hours before unit start-up to prevent compressor damage as a result of slugging.

Emergency Heat Function (Room Thermostat)

An emergency heat function is designed into some room thermostats. This feature is applicable when isolation of outdoor unit is required or when auxiliary electric heat is stage by outdoor thermostats. When the room thermostat is placed in the emergency heat position, the outdoor unit control circuit is isolated from power and the field-supplied relays bypass the outdoor thermostats. An amber indicating light simultaneously comes on to remind the homeowner that the unit is operating in the emergency heat mode.

Emergency heat is usually used during an outdoor shutdown, but it should also be used following a power outage if power has been off for over an hour and the outdoor temperature is below 50°F. System should be left in the emergency heat mode at least 6 hours to allow the crankcase heater sufficient time to prevent compressor slugging.

DEMAND DEFROST SYSTEM DESCRIPTION

The demand defrost controller measures differential temperatures to detect when the system is performing poorly because of ice build-up on the outdoor coil. The controller “self-calibrates” when the defrost system starts and after each system defrost cycle. The defrost control board components are shown below.

The control monitors ambient temperature, outdoor coil temperature, and total run time to determine when a defrost cycle is required. The coil temperature probe is designed with a spring clip to allow mounting to the outside coil tubing. The location of the coil sensor is important for proper defrost operation.

NOTE - The demand defrost board accurately measures the performance of the system as frost accumulates on the outdoor coil. This typically will translate into longer running time between defrost cycles as more frost accumulates on the outdoor coil before the board initiates defrost cycles.

DIAGNOSTIC LEDS

The state (Off, On, Flashing) of two LEDs on the defrost board (DS1 [Red] and DS2 [Green]) indicate diagnostics conditions that are described in table.

Mode

Green Led (DS2)

Red Led (DS1)

No power to control

OFF

OFF

Normal operation/

Simultaneous Slow Flash

power to control

 

 

Anti-short cycle

Alternating Slow Flash

 

lockout

 

 

 

Low pressure switch

OFF

Slow FLASH

fault (Optional)

 

 

Low pressure switch

OFF

ON

lockout (Optional)

 

 

High presssure switch

Slow FLASH

OFF

fault (Optional)

 

 

High pressure switch

OFF

OFF

lockout (Optional)

 

 

506468-01

Issue 1004

Page 17

Image 17
Contents 4HP16LT Series Torque Table Installation ClearancesGeneral Fastener TorqueSlab Mounting Electrical WiringSlab Mounting Roof MountingWith Auxiliary Heat Thermostat DesignationsWithout Auxiliary Heat Brazing Connection Procedure Outside Unit Placement InstallationInstalling Refrigerant Line Refrigerant Line Sets Transition from Vertical to Horizontal Refrigerant Line Sets Installing Horizontal RunsR22 refrigerant will be used to flush the system Flushing Existing Line Set and Indoor CoilFlushing Connections Manifold Gauge Set Liquid and Suction Line Service ValvesRefrigerant Metering Device Ball Type Service Valve Valve Open Service ValveTo Open Liquid or Suction Line Service Valve To Close Liquid or Suction Line Service ValveEvacuation Refrigerant Charging Refrigerant Charge AdjustmentAmbient temperature Cooling Cycle Charge Using Weigh-In MethodBlocking Outdoor Coil R410A Temperature/Pressure ChartNormal Operating Pressures Approach Values for TXV Systems Check Charge Using Normal Operating PressuresFilter Drier OperationSensor Temp. / Resistance Range Defrost Board Pressure Switch ConnectionsDelay Mode Issue Defrost Control Board Diagnostic LEDs Interpreting the Diagnostic LEDs System Diagnostic ModuleFlash Codes LED DescriptionShort Cycling 24VAC Power WiringMiswired Module Codes Miswired Module TroubleshootingThermostat Demand Wiring Maintenance Thermostat Operation Case of extended power outageHeat Pump Operation Preservice Check Cooling Start-Up and Performance ChecklistHeating Sequence of OperationSingle Stage Wire Diagram Two Stage Wire Diagram