Carrier RVC Configuration Top View-Left Return, Isometric, Configuration Left Return Left View

Page 11

 

 

 

 

 

WATER CONNECTIONS

ELECTRICAL KNOCKOUTS (in.)

DISCHARGE CONNECTION

RETURN CONNECTION

50RVR

 

OVERALL CABINET

1

2

3

Loop

G

H

I

Duct Flange Installed (±0.10 in.)

Using Air Coil Opening

 

 

 

 

1/2 conduit

1/2 conduit

3/4 conduit

 

 

 

 

 

 

 

 

 

UNITS

 

 

 

 

 

 

 

Water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

D

E

F

FPT

 

 

Power

 

 

L

M

 

 

P

Q

 

 

 

Cond-

(in.)

Therm

Ext Pump

J

K

Supply

Supply

N

O

Return

Return

R

 

 

Width

Depth

Height

In

Out

Supply

 

 

ensate

 

 

 

 

 

Height

Depth

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

009-012

in.

22.4

21.6

22.6

2.6

5.4

7.8

1/2

3.5

5.5

8.2

10.6

6.8

5.8

8.0

6.0

2.2

17.1

9.3

1.0

cm

56.8

54.9

57.4

6.6

13.7

19.8

8.9

14.0

20.8

26.9

17.3

14.7

20.3

15.2

5.6

43.4

23.6

2.5

 

 

015-024

in.

22.4

21.6

34.6

2.4

4.8

8.5

3/4

3.5

7.5

10.2

7.2

3.8

14.0

14.0

4.3

2.2

17.1

15.3

1.0

cm

56.8

54.9

87.9

6.1

12.2

21.6

8.9

19.1

25.9

18.3

9.7

35.6

35.6

10.9

5.6

43.4

38.9

2.5

 

 

030

in.

22.4

25.6

40.6

2.4

5.4

9.7

3/4

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

19.2

1.0

cm

56.8

65.1

103.1

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

48.8

2.5

 

 

036

in.

22.4

25.6

40.6

2.4

5.4

9.7

3/4

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

19.2

1.0

cm

56.8

65.1

103.1

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

48.8

2.5

 

 

042-048

in.

22.4

25.6

48.6

2.4

5.4

9.7

1

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

27.2

1.0

cm

56.8

65.1

123.4

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

69.1

2.5

 

 

060

in.

25.4

30.6

50.6

2.4

5.4

10.7

1

8.1

11.7

14.2

6.2

6.3

18.0

18.0

5.1

2.2

26.1

27.2

1.0

cm

64.5

77.8

128.5

6.1

13.7

27.2

20.6

29.7

36.1

15.7

16.0

45.7

45.7

13.0

5.6

66.3

69.1

2.5

 

 

NOTES:

1.Condensate is 3/4-in. FPT and is switchable from side to front.

2.Vertical unit shipped with filter bracket only extending from unit 2.5 inches. This bracket should be removed when connecting return duct.

3.Discharge flange field installed.

4.Right and left orientation is determined by looking at water connection side.

 

 

 

 

 

 

 

Field Installed

 

 

 

 

 

 

 

Discharge Flange

 

 

 

 

LEGEND

 

 

(Shipped loose in

 

 

 

 

 

 

blower section)

 

 

 

ASP — Alternate Service Panel

 

Standard Filter Bracket

 

 

 

 

 

 

 

 

BSP — Blower Service Panel

 

 

 

 

 

 

CAP — Control Access Panel

 

 

 

 

 

 

CSP — Compressor Service Panel

 

 

RIGHT RETURN

 

 

LEFT RETURN

 

 

Air Coil

 

 

 

 

 

 

 

 

M

K

 

B

 

 

BSP

 

K

M

 

 

 

 

 

 

 

 

L

Front

 

 

Front

L

 

 

 

 

 

 

 

 

 

 

 

A

CSP

 

 

 

 

 

 

 

 

 

 

 

 

 

CAP

Water Connection

Access Panels

ASP

3Service

Access

Left Return

ASP(right

Opposite)

N

Air Coil Side

 

 

Air Coil Side

J

 

 

 

 

 

 

 

R Configuration - Top View-Right Return

L Configuration - Top View-Left Return

Front

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Water

 

P

 

O

P

 

3Service

 

 

Isometric

 

Connections

 

O

 

 

 

 

 

 

 

Access

 

 

View

 

 

 

R

 

 

R

 

 

 

 

 

 

 

1.000

 

 

 

 

 

 

 

 

 

 

 

 

 

Air Coil

 

Air Coil

 

 

 

 

 

 

 

Q

 

 

Q

 

 

 

 

 

 

 

 

 

C

 

 

C

 

 

 

 

 

 

 

 

Condensate

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Supply

 

 

 

 

 

3/4FPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3/4HV Knockout

 

 

 

 

 

 

 

 

 

 

 

 

Power for

 

 

CAP

 

 

 

 

 

 

 

 

 

Condensate Pump

 

 

 

 

 

 

 

 

 

 

 

 

1/2Knockout

 

 

 

 

 

 

 

ASP

 

 

CSP

 

Low Voltage

 

 

I

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2LV Knockout

 

H

 

 

 

Front

 

Back

Back

 

Front

CSP

G

 

2

 

F

 

 

 

 

1

 

E

 

 

 

 

 

 

 

 

 

D

 

 

 

 

 

 

 

 

 

 

 

R Configuration - Right Return Right View

L Configuration - Left Return Left View

 

 

Front View

 

 

 

 

- Air Coil Opening

 

 

- Air Coil Opening

 

 

 

 

 

 

 

 

 

AIRFLOW CONFIGURATION

 

 

 

 

 

 

 

 

 

 

Code

Return

Discharge

 

 

 

 

 

 

 

 

 

L

Left

 

Top

 

 

 

 

 

 

 

 

 

R

Right

 

Top

 

 

 

 

 

 

 

 

 

Fig. 6 — 50RVR Dimensional Data

11

Image 11
Contents Safety Considerations ContentsGeneral InstallationPage PSC FAN Motor and Blower Physical Data Aquazone 50RHC,RVC006-060 UnitsPermanent Split Capacitor Physical Data Aquazone 50RHR,RVR006-060 UnitsPhysical Data Aquazone 50RHS,RVS,RDS015-070 Units Right Airflow ConfigurationCode Return Discharge 030 Ext Power Cond Therm Supply ReturnDepth Height Out Pump Supply Ensate 015-024Right Back Back RightTypical Installation 50RHC,RHR,RHS Units Right Top TopView Configuration Top View-Left ReturnConfiguration Left Return Left View IsometricFront View Configuration Left Return Left View Air Coil OpeningIsometric View CodeFront-View Ht Return/Bottom DischargeReturn/Bottom Discharge Isometric View Top ViewMove to Side Remove ScrewsSide Discharge Rotate50RHS Units Mounting the Unit50RHC Units 50RHR UnitsHorizontal Unit Pitch Condensate DrainCondition Acceptable Level Field Control Wiring Field Power Supply WiringCompr LOCBMC NECRVS Typical Aquazone Deluxe D Control WiringTrans HpwsLON A50-8154 Low Voltage Field Wiring RLA 50RHC,RVC Electrical DataRLA LRA Motor Unit Circuit FUSE/HACR FLARLA LRA FUSE/HACR 50RHR,RVR VOLTS-PHASE Voltage Compressor FAN Total MIN MAX50RHR,RVR Electrical Data Unit Circuit Units50RDS, RHS, RVS Electrical Data PRE-START-UPSpeed 50RHR,RVR Blower Performance50RHR,RVR Rated MIN FAN 50RHC,RVC Rated MIN FAN 50RHC,RVC Blower Performance50RVC Blower Performance with Hot Water Reheat HWR Option Reheat External Static Pressure ESP Loss Coil Face Velocity50RHS,RVS,RDS Rated FAN 50RVC Blower Performance with Wet Coil50RHS,RVS,RDS Blower Performance Coil Face Velocity WET Coil ReductionCoil Face 50RHS, RVS with Reheat ESP Loss Control Jumper Settings See FigField Selectable Inputs 50RHS, RVS Blower Performance with HWRAccessory DIP Switch Position Relay Options DIP Switch Block S2 Accessory 1 Relay OptionsDIP Switch Block S2 Accessory 2 Relay Options Humidistat/Dehumidistat Logic Deluxe D DIP Switch SettingsOutput Control Accessory Relay ConfigurationsSTART-UP HWR Operating ModesOperating Limits 50RHC,RVC Units Unit Start-Up Cooling ModeWater Temperature Change Through Heat Exchanger Operating LimitsTemp F TON Unit Start-Up Heating ModeTypical Unit Operating Pressures and Temperatures Entering Cooling Heating Water GPM50RHC,RVC Coaxial Water Pressure Drop 50RHR,RVR Coaxial Water Pressure Drop50RHS,RVS,RDS Coaxial Water Pressure Drop Units with Aquazone Complete C Control Approximate Fluid Volume gal Per 100 Ft of PipeAntifreeze Percentages by Volume OperationSystem Test Complete C Control LED Code Fault DescriptionsUnits with HWR Option ESD ServiceAquazone Deluxe D Control LED Indica Gravity Flow Method Air Coil Fan Motor Removal TroubleshootingRefrigerant Charging Fault Heating Cooling Possible Cause Solution TroubleshootingUnit Does Not Operate II. START-UP 50RHC,RVC,RHR,RHS,RVR,RVS,RDS START-UP ChecklistCooling Cycle Analysis Heating Cycle Analysis