Carrier RDS006-060, RVS, RVR, RHR, RVC, RHS, 50RHC specifications Back Right, Right Back

Page 8

 

 

 

 

 

 

WATER CONNECTIONS

ELECTRICAL KNOCKOUTS (in.)

 

 

DISCHARGE CONNECTION

 

RETURN CONNECTION

 

 

OVERALL CABINET

1

2

3

Loop

 

G

H

I

 

Duct Flange Installed (±0.10 in.)

 

Using Air Coil Opening

50RHS

 

 

 

HWG

 

 

 

 

 

 

 

 

1/2 conduit

1/2 conduit

3/4 conduit

 

 

 

 

 

 

 

 

 

 

 

 

UNITS

 

 

 

 

 

 

Water

FPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

D

E

F

FPT

(in.)

 

 

Power

 

 

 

L

M

 

 

 

P

Q

 

 

 

 

Cond-

(in.)

Therm

Ext Pump

J

 

K

Supply

Supply

N

 

O

Return

Return

R

S

 

 

Width

Depth

Height

In

Out

 

Supply

 

 

 

 

 

 

 

 

 

ensate

 

 

 

 

 

 

 

 

Height

Depth

 

 

 

Depth

Height

 

 

015-018

in.

22.4

53.2

19.3

2.4

5.4

0.6

3/4

1/2

5.7

9.7

12.2

5.0

 

6.8

10.4

9.3

5.0

 

2.1

23.1

17.3

2.2

1.0

cm

56.8

135.1

49.0

6.1

13.7

1.5

14.5

24.6

31.0

12.7

 

17.3

26.4

23.6

12.7

 

5.3

58.7

43.9

5.6

2.5

024-030

in.

22.4

62.2

19.3

2.4

5.4

0.6

3/4

1/2

5.7

9.7

12.2

5.0

 

6.8

10.4

9.3

5.0

 

2.1

28.1

17.3

2.2

1.0

cm

56.8

158.0

49.0

6.1

13.7

1.5

14.5

24.6

31.0

12.7

 

17.3

26.4

23.6

12.7

 

5.3

71.4

43.9

5.6

2.5

036

in.

22.4

62.2

19.3

2.4

5.4

0.6

3/4

1/2

5.7

9.7

12.2

5.0

 

6.8

10.4

9.3

5.0

 

2.1

32.1

17.3

2.2

1.0

cm

56.8

158.0

49.0

6.1

13.7

1.5

14.5

24.6

31.0

12.7

 

17.3

26.4

23.6

12.7

 

5.3

81.5

43.9

5.6

2.5

 

 

 

 

 

042-048

in.

25.4

71.2

21.3

2.4

5.4

0.6

1

1/2

8.1

11.7

14.2

5.8

 

5.0

13.6

13.3

5.8

 

2.9

36.1

19.3

2.2

1.0

cm

64.5

180.8

54.1

6.1

13.7

1.5

20.6

29.7

36.1

14.7

 

12.7

34.5

33.8

14.7

 

7.4

91.7

49.0

5.6

2.5

060

in.

25.4

76.2

21.3

2.4

5.4

0.6

1

1/2

8.1

11.7

14.2

5.8

 

5.0

13.6

13.3

5.8

 

2.9

41.1

19.3

2.2

1.0

cm

64.5

193.5

54.1

6.1

13.7

1.5

20.6

29.7

36.1

14.7

 

12.7

34.5

33.8

14.7

 

7.4

104.4

49.0

5.6

2.5

 

 

 

 

 

070

in.

25.4

81.2

21.3

2.4

5.4

0.6

1

1/2

8.1

11.7

14.2

5.8

 

5.0

13.6

13.3

5.8

 

2.9

46.1

19.3

2.2

1.0

cm

64.5

206.2

54.1

6.1

13.7

1.5

20.6

29.7

36.1

14.7

 

12.7

34.5

33.8

14.7

 

7.4

117.1

49.0

5.6

2.5

 

 

 

 

 

NOTES:

1.Condensate is 3/4-in. FPT copper.

2.Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection.

3.Hanger kit is factory installed. Isolation grommets are provided.

4.Right and left orientation is determined by looking at water connection side.

LEGEND

ASP — Alternate Service Panel

BSP — Blower Service Panel

CAP — Control Access Panel

CSP — Compressor Service Panel

AIRFLOW CONFIGURATION

Code

Return

Discharge

 

S

Left

Right

 

E

Left

Back

 

Z

Right

Left

 

B

Right

Back

 

 

 

Fig. 3 — 50RHS Dimensional Data

8

Image 8
Contents Contents Safety ConsiderationsInstallation GeneralPage Physical Data Aquazone 50RHC,RVC006-060 Units PSC FAN Motor and BlowerPermanent Split Capacitor Physical Data Aquazone 50RHR,RVR006-060 UnitsPhysical Data Aquazone 50RHS,RVS,RDS015-070 Units Right Airflow ConfigurationCode Return Discharge Ext Power Cond Therm Supply Return Depth Height Out Pump Supply Ensate015-024 030Back Right Right BackTypical Installation 50RHC,RHR,RHS Units Top Right TopConfiguration Top View-Left Return Configuration Left Return Left ViewIsometric ViewConfiguration Left Return Left View Air Coil Opening Isometric ViewCode Front ViewHt Return/Bottom Discharge Return/Bottom Discharge Isometric ViewTop View Front-ViewRemove Screws Side DischargeRotate Move to SideMounting the Unit 50RHC Units50RHR Units 50RHS UnitsCondensate Drain Horizontal Unit PitchCondition Acceptable Level Field Power Supply Wiring Field Control WiringLOC BMCNEC ComprTypical Aquazone Deluxe D Control Wiring RVSTrans HpwsLON A50-8154 Low Voltage Field Wiring 50RHC,RVC Electrical Data RLA LRA Motor Unit Circuit FUSE/HACRFLA RLA50RHR,RVR VOLTS-PHASE Voltage Compressor FAN Total MIN MAX 50RHR,RVR Electrical DataUnit Circuit Units RLA LRA FUSE/HACRPRE-START-UP 50RDS, RHS, RVS Electrical DataSpeed 50RHR,RVR Blower Performance50RHR,RVR Rated MIN FAN 50RHC,RVC Blower Performance 50RVC Blower Performance with Hot Water Reheat HWR OptionReheat External Static Pressure ESP Loss Coil Face Velocity 50RHC,RVC Rated MIN FAN50RVC Blower Performance with Wet Coil 50RHS,RVS,RDS Blower PerformanceCoil Face Velocity WET Coil Reduction 50RHS,RVS,RDS Rated FANControl Jumper Settings See Fig Field Selectable Inputs50RHS, RVS Blower Performance with HWR Coil Face 50RHS, RVS with Reheat ESP LossDIP Switch Block S2 Accessory 1 Relay Options DIP Switch Block S2 Accessory 2 Relay OptionsHumidistat/Dehumidistat Logic Deluxe D DIP Switch Settings Accessory DIP Switch Position Relay OptionsControl Accessory Relay Configurations START-UPHWR Operating Modes OutputUnit Start-Up Cooling Mode Water Temperature Change Through Heat ExchangerOperating Limits Operating Limits 50RHC,RVC UnitsUnit Start-Up Heating Mode Typical Unit Operating Pressures and TemperaturesEntering Cooling Heating Water GPM Temp F TON50RHC,RVC Coaxial Water Pressure Drop 50RHR,RVR Coaxial Water Pressure Drop50RHS,RVS,RDS Coaxial Water Pressure Drop Approximate Fluid Volume gal Per 100 Ft of Pipe Antifreeze Percentages by VolumeOperation Units with Aquazone Complete C ControlSystem Test Complete C Control LED Code Fault DescriptionsUnits with HWR Option ESD ServiceAquazone Deluxe D Control LED Indica Gravity Flow Method Air Coil Fan Motor Removal TroubleshootingRefrigerant Charging Troubleshooting Fault Heating Cooling Possible Cause SolutionUnit Does Not Operate 50RHC,RVC,RHR,RHS,RVR,RVS,RDS START-UP Checklist II. START-UPHeating Cycle Analysis Cooling Cycle Analysis