| WATER |
|
| ELECTRICAL KNOCKOUTS (in.) |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
| OVERALL |
| CONNECTIONS |
|
| DISCHARGE CONNECTION |
| RETURN CONNECTION | ||||||||||||||
|
|
|
|
|
|
|
|
|
|
| ||||||||||||||
50RHR |
| CABINET |
| 1 | 2 | 3 | Loop | G |
| H | I |
| Duct Flange Installed (±0.10 in.) |
| Using Return Air Opening | |||||||||
|
|
| 1/2 conduit 1/2 conduit | 3/4 conduit |
|
|
|
|
|
|
|
|
|
|
| |||||||||
UNITS |
|
|
|
|
|
| F | Water |
|
|
|
|
| L |
| M |
|
| P | Q |
|
| ||
|
| A | B | C | D | E | FPT |
|
| Ext | Power |
|
|
|
|
|
|
| ||||||
|
| Cond- | (in.) | Therm |
| J | K | Supply | Supply | N | O | Return | Return | R | S | |||||||||
|
| Width | Depth | Height | In | Out |
| Pump | Supply | |||||||||||||||
|
| ensate |
|
|
|
|
|
| Height | Depth |
|
| Depth | Height |
|
| ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
in. | 22.4 | 43.1 | 11.3 | 2.4 | 5.4 | 0.6 |
| 1/2 | 3.5 |
| 5.5 | 8.2 | 5.8 | 4.0 | 5.8 |
| 8.0 | 5.8 | 1.5 | 17.1 | 9.3 | 2.2 | 1.0 | |
cm | 56.8 | 109.5 | 28.7 | 6.1 | 13.7 | 1.5 |
| 8.9 |
| 14.0 | 20.8 | 14.7 | 10.2 | 14.7 |
| 20.3 | 14.7 | 3.8 | 43.4 | 23.6 | 5.6 | 2.5 | ||
| in. | 22.4 | 43.1 | 17.3 | 2.4 | 4.9 | 0.6 |
| 3/4 | 3.5 |
| 7.5 | 10.2 | 5.0 | 5.6 | 10.4 |
| 9.3 | 5.0 | 1.5 | 17.1 | 15.3 | 2.2 | 1.0 |
cm | 56.8 | 109.5 | 43.9 | 6.1 | 12.4 | 1.5 |
| 8.9 |
| 19.1 | 25.9 | 12.7 | 14.2 | 26.4 |
| 23.6 | 12.7 | 3.8 | 43.4 | 38.9 | 5.6 | 2.5 | ||
030 | in. | 22.4 | 53.2 | 19.3 | 2.4 | 5.4 | 0.6 |
| 3/4 | 5.7 |
| 9.7 | 12.2 | 5.0 | 6.8 | 10.4 |
| 9.3 | 5.0 | 2.1 | 23.1 | 17.3 | 2.2 | 1.0 |
cm | 56.8 | 135.1 | 49.0 | 6.1 | 13.7 | 1.5 |
| 14.5 |
| 24.6 | 31.0 | 12.7 | 17.3 | 26.4 |
| 23.6 | 12.7 | 5.3 | 58.7 | 43.9 | 5.6 | 2.5 | ||
|
|
|
|
| ||||||||||||||||||||
036 | in. | 22.4 | 53.2 | 19.3 | 2.4 | 5.4 | 0.6 |
| 3/4 | 5.7 |
| 9.7 | 12.2 | 2.9 | 3.8 | 13.5 |
| 13.1 | 2.9 | 1.9 | 23.1 | 17.3 | 2.2 | 1.0 |
cm | 56.8 | 135.1 | 49.0 | 6.1 | 13.7 | 1.5 |
| 14.5 |
| 24.6 | 31.0 | 7.4 | 9.7 | 34.3 |
| 33.3 | 7.4 | 4.8 | 58.7 | 43.9 | 5.6 | 2.5 | ||
|
|
|
|
| ||||||||||||||||||||
| in. | 22.4 | 62.2 | 19.3 | 2.4 | 5.4 | 0.6 |
| 1 | 5.7 |
| 9.7 | 12.2 | 2.9 | 3.8 | 13.5 |
| 13.1 | 2.9 | 1.9 | 32.1 | 17.3 | 2.2 | 1.0 |
cm | 56.8 | 158.0 | 49.0 | 6.1 | 13.7 | 1.5 |
| 14.5 |
| 24.6 | 31.0 | 7.4 | 9.7 | 34.3 |
| 33.3 | 7.4 | 4.8 | 81.5 | 43.9 | 5.6 | 2.5 | ||
060 | in. | 25.4 | 71.2 | 21.3 | 2.4 | 5.4 | 0.6 |
| 1 | 8.1 |
| 11.7 | 14.2 | 5.8 | 5.0 | 13.6 |
| 13.3 | 5.8 | 2.9 | 36.1 | 19.3 | 2.2 | 1.0 |
cm | 64.5 | 180.8 | 54.1 | 6.1 | 13.7 | 1.5 |
| 20.6 |
| 29.7 | 36.1 | 14.7 | 12.7 | 34.5 |
| 33.8 | 14.7 | 7.4 | 91.7 | 49.0 | 5.6 | 2.5 | ||
|
|
|
|
| ||||||||||||||||||||
NOTES: |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
1. Condensate is | ²±¢p³µ¶·¸¹º»¼½¾¿ÀÁÂ?‘’“”•…†‡denµ´ÇÆÅÄ´ |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||||||||
2. Horizontal unit shipped with filter bracket only. This bracket should be removed for return duct connection. |
|
|
|
|
|
|
|
|
|
|
| |||||||||||||
3. Hanger kit is factory installed3op?œŸ•‘. “Isolation’ | grommets are provided. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||
4. Right and left orientation is determined by looking at water connection side. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||||||||
|
|
|
|
|
|
|
|
|
|
|
| LEGEND |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
| LEFT RETURN |
|
| ASP — Alternate Service Panel |
|
|
|
| RIGHT RETURN Water |
|
|
| |||||||||
|
|
|
|
|
| BSP | — Blower Service Panel |
|
|
|
|
|
|
| ||||||||||
|
|
| Water |
|
|
|
|
|
| CAP | — Control Access Panel |
|
|
|
|
| ASP | Connection |
|
| ||||
|
|
| Connection |
| CSP |
|
|
|
| CSP | — Compressor Service Panel |
|
|
|
| Front | 2‘ Service |
| ||||||
| 3‘ Service |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Access |
| ||||
| Front |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| Access |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| Left Return | Power Supply |
|
| Right Return |
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
| 3/4“ Knockout |
|
|
|
|
|
|
|
|
| |||||
|
|
| ASP |
|
|
|
|
|
| 1/2“ |
| 1.6 [40.6mm] |
|
|
|
|
|
|
| CSP |
|
| ||
|
|
|
|
|
|
|
|
|
| 3.25 Knockout |
|
|
|
|
|
|
|
|
|
|
| |||
|
|
|
|
|
|
|
|
|
|
|
|
| 3.25 |
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| Low Voltage |
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| 1/2“ Knockout |
| I |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
|
| Right |
|
|
|
|
| F |
| H | CAP |
| F |
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
| 3 |
| G | 2 |
|
|
|
|
|
| Left |
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
| 3 |
|
|
|
|
|
|
| ||||||
|
|
| Discharge |
|
|
|
|
|
|
| 1 | D E |
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Discharge |
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
| Back |
| Condensate |
|
| A |
| Condensate |
| Back |
|
|
|
|
|
| ||
|
|
|
|
|
|
| Discharge | 3/4“ FPT |
|
|
|
|
|
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| 3/4“ FTP | Discharge |
|
|
|
|
|
| ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| M | O |
|
|
|
| N | M | Side |
|
|
| Unit Hanger Detail |
|
| Side | Blower | BSP | |||
BSP |
|
| CoilAir | C |
| Front | Model | X | Y | Z |
|
| CoilAir | L | |
|
|
|
|
|
| ||||||||||
|
|
|
| 62.1 | 24.375 | 20.375 |
|
|
| ||||||
| Blower |
|
| Y |
| 43.1 | 24.375 | 20.375 |
| Z |
| Outlet |
| ||
| L | Outlet |
|
|
| 53.1 | 24.375 | 20.375 |
|
|
|
| |||
|
|
|
|
|
|
|
|
|
| ||||||
|
|
|
|
|
|
| 060 | 71.1 | 27.375 | 23.375 |
|
|
|
| N |
| O |
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
|
| A |
|
|
|
|
|
| X |
|
|
|
| A |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
E Configuration - Left Return Back Discharge | M |
| J |
|
|
|
|
| B Configuration - Right Return Back Discharge | ||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| K |
| M |
|
|
|
|
|
|
|
| Blower | BSP |
|
|
|
|
|
| Left | ||
| ASP |
|
|
|
| BSP |
|
|
|
| |||||
|
|
|
| Outlet |
|
|
|
| CSP | View | |||||
Right |
|
|
| L |
|
| Blower |
| |||||||
View |
|
|
|
|
|
|
|
|
|
|
| L |
|
| |
|
|
|
|
|
|
|
|
|
|
| Outlet |
|
| ||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
Front |
|
|
|
|
|
| K |
| 3‘ |
|
|
|
| Front | |
|
|
|
|
|
|
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
| SERVICE | M |
|
|
|
| |
| S Configuration - Left Return Right Discharge - |
|
| ACCESS | Z Configuration - Right Return Left Discharge - | ||||||||||
|
|
|
| ||||||||||||
|
|
| Air Coil Opening |
|
|
|
|
|
|
|
| Air Coil Opening |
|
|
SR
ViewLeft C Q
P | Air Coil | 1.1 |
CSP
B
S Configuration - Left Return Right Discharge -
Air Coil Opening
|
| Air Coil |
| S |
|
| P | R | |
| C | ASP |
| Q Right |
|
|
| ||
|
|
|
| View |
Front | Front |
|
|
|
|
| B |
|
|
|
| Z Configuration - Right Return Left Discharge - |
|
|
|
| Air Coil Opening |
|
|
AIRFLOW CONFIGURATION
Code | Return | Discharge |
|
S | Left | Right |
|
E | Left | Back |
|
Z | Right | Left |
|
B | Right | Back |
|
|
| Fig. 2 — 50RHR Dimensional Data |