Carrier RHS, RVS, RDS006-060, RVR, RHR, RVC, 50RHC Loc, Bmc, Nec, Compr, Txv, FP1, FP2, Hwts, JW1

Page 19

a50-8160

 

 

 

LEGEND

 

 

 

 

 

 

 

 

 

 

 

AL

Alarm Relay Contacts

LOC

Loss of Charge Pressure Switch

 

 

 

 

 

 

 

 

 

Relay/Contactor Coil

BM

Blower Motor

MV

Motorized Valve

 

 

 

 

 

 

 

 

 

BMC

Blower Motor Capacitor

NEC

National Electrical Code

 

 

 

 

 

 

 

 

 

 

BR

Blower Relay

P1

Field Wiring Terminal Block

 

 

 

 

 

 

 

 

 

Condensate Pan

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CB

Circuit Breaker

PM

Performance Monitor

 

 

 

 

 

 

 

 

 

 

CC

Compressor Contactor

RV

Reversing Valve Coil

 

 

 

 

 

 

 

 

 

Solenoid Coil

CO

Sensor, Condensate Overflow

TRANS — Transformer

 

 

 

 

 

 

 

 

 

Temperature Switch

COMPR

Compressor

TXV

Thermostatic Expansion Valve

 

 

 

 

 

 

 

 

 

FP1

Sensor, Water Coil Freeze Protection

 

Field Line Voltage Wiring

 

 

 

 

 

 

 

 

 

Thermistor

FP2

Sensor, Air Coil Freeze Protection

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field Low Voltage Wiring

 

 

 

 

 

 

 

 

 

 

HP

High-Pressure Switch

 

 

 

 

 

 

 

 

 

 

Ground

HWTS

High (Leaving) Water Temperature

 

Printed Circuit Trace

 

 

 

 

 

 

 

 

 

Wire Nut

 

Switch

 

Optional Wiring

 

 

 

 

 

 

 

 

 

JW1

Jumper, Alarm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Optional wiring.

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1. Compressor and blower motor thermally protected internally.

 

6. 24-v alarm signal shown. For dry alarm contact, cut JW1 jumper

2. All wiring to the unit must comply with NEC and local codes.

 

and dry contact will be available between AL1 and AL2.

3. Transformer is wired to 265 v (BRN) lead for 265/1/60 units, or

7. Transformer secondary ground via control board standoffs and

208 v (RED) lead for 208/1/60. For 230/1/60 switch RED and

screws to control box. (Ground available from top two standoffs

ORG leads at L1 and insulate RED lead. Transformer is energy

as shown.)

 

 

 

 

 

 

 

 

 

 

limiting or may have circuit breaker.

 

 

8. For high or low speed

remove BLU wire from BR ‘NO’

4. FP1 thermistor provides freeze protection for water. When using

and replace with BLK or RED wire respectively. Tape off unused

antifreeze solutions, cut JW3 jumper.

 

 

terminal.

 

 

 

 

 

 

 

 

 

 

5. Typical Aquazone thermostat wiring shown. Refer to thermostat

9. Both DIP switches need to be in the ON position.

installation instructions for wiring to the unit. Thermostat wiring

 

 

 

 

 

 

 

 

 

 

 

must be Class 1 and voltage rating equal to or greater than unit

 

 

 

 

 

 

 

 

 

 

 

supply voltage.

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 19 — Typical Aquazone™ Complete C Control Wiring

19

Image 19
Contents Safety Considerations ContentsGeneral InstallationPage PSC FAN Motor and Blower Physical Data Aquazone 50RHC,RVC006-060 UnitsPhysical Data Aquazone 50RHS,RVS,RDS015-070 Units Physical Data Aquazone 50RHR,RVR006-060 UnitsPermanent Split Capacitor Code Return Discharge Airflow ConfigurationRight 030 Ext Power Cond Therm Supply ReturnDepth Height Out Pump Supply Ensate 015-024Right Back Back RightTypical Installation 50RHC,RHR,RHS Units Right Top TopView Configuration Top View-Left ReturnConfiguration Left Return Left View IsometricFront View Configuration Left Return Left View Air Coil OpeningIsometric View CodeFront-View Ht Return/Bottom DischargeReturn/Bottom Discharge Isometric View Top ViewMove to Side Remove ScrewsSide Discharge Rotate50RHS Units Mounting the Unit50RHC Units 50RHR UnitsHorizontal Unit Pitch Condensate DrainCondition Acceptable Level Field Control Wiring Field Power Supply WiringCompr LOCBMC NECRVS Typical Aquazone Deluxe D Control WiringLON HpwsTrans A50-8154 Low Voltage Field Wiring RLA 50RHC,RVC Electrical DataRLA LRA Motor Unit Circuit FUSE/HACR FLARLA LRA FUSE/HACR 50RHR,RVR VOLTS-PHASE Voltage Compressor FAN Total MIN MAX50RHR,RVR Electrical Data Unit Circuit Units50RDS, RHS, RVS Electrical Data PRE-START-UP50RHR,RVR Rated MIN FAN 50RHR,RVR Blower PerformanceSpeed 50RHC,RVC Rated MIN FAN 50RHC,RVC Blower Performance50RVC Blower Performance with Hot Water Reheat HWR Option Reheat External Static Pressure ESP Loss Coil Face Velocity50RHS,RVS,RDS Rated FAN 50RVC Blower Performance with Wet Coil50RHS,RVS,RDS Blower Performance Coil Face Velocity WET Coil ReductionCoil Face 50RHS, RVS with Reheat ESP Loss Control Jumper Settings See FigField Selectable Inputs 50RHS, RVS Blower Performance with HWRAccessory DIP Switch Position Relay Options DIP Switch Block S2 Accessory 1 Relay OptionsDIP Switch Block S2 Accessory 2 Relay Options Humidistat/Dehumidistat Logic Deluxe D DIP Switch SettingsOutput Control Accessory Relay ConfigurationsSTART-UP HWR Operating ModesOperating Limits 50RHC,RVC Units Unit Start-Up Cooling ModeWater Temperature Change Through Heat Exchanger Operating LimitsTemp F TON Unit Start-Up Heating ModeTypical Unit Operating Pressures and Temperatures Entering Cooling Heating Water GPM50RHS,RVS,RDS Coaxial Water Pressure Drop 50RHR,RVR Coaxial Water Pressure Drop50RHC,RVC Coaxial Water Pressure Drop Units with Aquazone Complete C Control Approximate Fluid Volume gal Per 100 Ft of PipeAntifreeze Percentages by Volume OperationUnits with HWR Option Complete C Control LED Code Fault DescriptionsSystem Test Aquazone Deluxe D Control LED Indica ServiceESD Gravity Flow Method Refrigerant Charging TroubleshootingAir Coil Fan Motor Removal Fault Heating Cooling Possible Cause Solution TroubleshootingUnit Does Not Operate II. START-UP 50RHC,RVC,RHR,RHS,RVR,RVS,RDS START-UP ChecklistCooling Cycle Analysis Heating Cycle Analysis