Carrier RHS, RVS, RVR Isometric View, Configuration Left Return Left View Air Coil Opening, Code

Page 12

 

 

 

 

 

 

 

WATER CONNECTIONS

 

ELECTRICAL KNOCKOUTS (in.)

DISCHARGE CONNECTION

RETURN CONNECTION

 

 

 

OVERALL CABINET

1

2

3

Loop

 

G

H

I

Duct Flange Installed (±0.10 in.)

Using Air Coil Opening

50RVS

 

 

 

 

HWG

 

 

 

 

 

 

 

1/2 conduit

1/2 conduit

3/4 conduit

 

 

 

 

 

 

 

 

 

UNITS

 

 

 

 

 

 

 

Water

FPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

B

C

D

E

F

FPT

(in.)

 

 

Power

 

 

L

M

 

 

P

Q

 

 

 

 

Cond-

(in.)

Therm

Ext Pump

J

K

Supply

Supply

N

O

Return

Return

R

 

 

 

Width

Depth

Height

In

Out

 

Supply

 

 

 

ensate

 

 

 

 

 

 

Height

Depth

 

 

Depth

Height

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

015-018

 

in.

22.4

25.6

40.6

2.4

5.4

9.7

3/4

1/2

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

19.2

1.0

 

cm

56.8

65.1

103.1

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

48.8

2.5

 

 

 

 

024-030

 

in.

22.4

25.6

44.6

2.4

5.4

9.7

3/4

1/2

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

23.2

1.0

 

cm

56.8

65.1

113.3

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

58.9

2.5

 

 

 

 

036

 

in.

22.4

25.6

48.6

2.4

5.4

9.7

3/4

1/2

5.7

9.7

12.2

7.2

5.8

14.0

14.0

4.3

2.2

21.1

27.2

1.0

 

cm

56.8

65.1

123.4

6.1

13.7

24.6

14.5

24.6

31.0

18.3

14.7

35.6

35.6

10.9

5.6

53.6

69.1

2.5

 

 

 

 

042-048

 

in.

25.4

30.6

50.6

2.4

5.4

10.7

1

1/2

8.1

11.7

14.2

6.2

6.3

18.0

18.0

5.1

2.2

26.1

27.2

1.0

 

cm

64.5

77.8

128.5

6.1

13.7

27.2

20.6

29.7

36.1

15.7

16.0

45.7

45.7

13.0

5.6

66.3

69.1

2.5

 

 

 

 

060

 

in.

25.4

30.6

54.6

2.4

5.4

10.7

1

1/2

8.1

11.7

14.2

6.2

6.3

18.0

18.0

5.1

2.2

26.1

31.2

1.0

 

cm

64.5

77.8

138.7

6.1

13.7

27.2

20.6

29.7

36.1

15.7

16.0

45.7

45.7

13.0

5.6

66.3

79.2

2.5

 

 

 

 

070

 

in.

25.4

30.6

58.6

2.4

5.4

10.7

1

1/2

8.1

11.7

14.2

6.2

6.3

18.0

18.0

5.1

2.2

26.1

35.2

1.0

 

cm

64.5

77.8

148.8

6.1

13.7

27.2

20.6

29.7

36.1

15.7

16.0

45.7

45.7

13.0

5.6

66.3

89.4

2.5

 

 

 

 

NOTES:

1.Condensate is 3/4-in. FPT and is switchable from side to front.

2.Vertical unit shipped with filter bracket only extending from unit 2.5 inches. This bracket should be removed when connecting return duct.

3.Discharge flange field installed.

4.Right and left orientation is determined by looking at water connection side.

LEGEND

ASP — Alternate Service Panel

BSP — Blower Service Panel

CAP — Control Access Panel

CSP — Compressor Service Panel

Field Installed

Discharge Flange (Shipped loose in blower section)

Standard Filter Bracket

Water Connection

Access Panels

 

RIGHT RETURN

 

 

LEFT RETURN

 

 

 

 

 

 

 

 

Air Coil

 

M

K

 

B

 

 

 

K

M

 

 

 

 

 

 

 

L

Front

 

 

Front

L

 

 

 

 

 

 

 

 

A

CSP

 

 

 

 

 

ASP

BSP

3Service

Access

Left Return

ASP(right

CAP

Opposite)

N

Air Coil Side

 

 

Air Coil Side

J

 

R Configuration - Top View-Right Return

L Configuration - Top View-Left Return

Front

 

 

P

O

O

P

 

3Service

 

 

Access

Isometric

View

Water Connections

R

R

1.000

Q

C

ASP

Air Coil

Q

C

CSP

Air Coil

Power Supply

3/4HV Knockout

Power for

Condensate Pump

1/2Knockout

Low Voltage

1/2LV Knockout

Condensate 3/4FPT

 

CAP

 

 

 

I

3

 

H

 

 

 

2

F

Front

 

 

Back

Back

 

 

Front

CSP

 

 

 

 

 

 

 

 

 

R Configuration - Right Return Right View

L Configuration - Left Return Left View

 

 

 

 

- Air Coil Opening

 

 

 

 

- Air Coil Opening

 

 

 

 

 

 

 

 

 

 

 

 

 

AIRFLOW CONFIGURATION

 

 

 

 

a50-8169

 

Code

 

Return

 

Discharge

 

 

 

 

L

 

Left

 

 

Top

 

 

 

 

 

R

 

Right

 

 

Top

 

 

 

 

Fig. 7 — 50RVS Dimensional Data

G

1

D

E

 

 

Front View

12

Image 12
Contents Contents Safety ConsiderationsInstallation GeneralPage Physical Data Aquazone 50RHC,RVC006-060 Units PSC FAN Motor and BlowerPhysical Data Aquazone 50RHR,RVR006-060 Units Physical Data Aquazone 50RHS,RVS,RDS015-070 UnitsPermanent Split Capacitor Airflow Configuration Code Return DischargeRight Ext Power Cond Therm Supply Return Depth Height Out Pump Supply Ensate015-024 030Back Right Right BackTypical Installation 50RHC,RHR,RHS Units Top Right TopConfiguration Top View-Left Return Configuration Left Return Left ViewIsometric ViewConfiguration Left Return Left View Air Coil Opening Isometric ViewCode Front ViewHt Return/Bottom Discharge Return/Bottom Discharge Isometric ViewTop View Front-ViewRemove Screws Side DischargeRotate Move to SideMounting the Unit 50RHC Units50RHR Units 50RHS UnitsCondensate Drain Horizontal Unit PitchCondition Acceptable Level Field Power Supply Wiring Field Control WiringLOC BMCNEC ComprTypical Aquazone Deluxe D Control Wiring RVSHpws LONTrans A50-8154 Low Voltage Field Wiring 50RHC,RVC Electrical Data RLA LRA Motor Unit Circuit FUSE/HACRFLA RLA50RHR,RVR VOLTS-PHASE Voltage Compressor FAN Total MIN MAX 50RHR,RVR Electrical DataUnit Circuit Units RLA LRA FUSE/HACRPRE-START-UP 50RDS, RHS, RVS Electrical Data50RHR,RVR Blower Performance 50RHR,RVR Rated MIN FANSpeed 50RHC,RVC Blower Performance 50RVC Blower Performance with Hot Water Reheat HWR OptionReheat External Static Pressure ESP Loss Coil Face Velocity 50RHC,RVC Rated MIN FAN50RVC Blower Performance with Wet Coil 50RHS,RVS,RDS Blower PerformanceCoil Face Velocity WET Coil Reduction 50RHS,RVS,RDS Rated FANControl Jumper Settings See Fig Field Selectable Inputs50RHS, RVS Blower Performance with HWR Coil Face 50RHS, RVS with Reheat ESP LossDIP Switch Block S2 Accessory 1 Relay Options DIP Switch Block S2 Accessory 2 Relay OptionsHumidistat/Dehumidistat Logic Deluxe D DIP Switch Settings Accessory DIP Switch Position Relay OptionsControl Accessory Relay Configurations START-UPHWR Operating Modes OutputUnit Start-Up Cooling Mode Water Temperature Change Through Heat ExchangerOperating Limits Operating Limits 50RHC,RVC UnitsUnit Start-Up Heating Mode Typical Unit Operating Pressures and TemperaturesEntering Cooling Heating Water GPM Temp F TON50RHR,RVR Coaxial Water Pressure Drop 50RHS,RVS,RDS Coaxial Water Pressure Drop50RHC,RVC Coaxial Water Pressure Drop Approximate Fluid Volume gal Per 100 Ft of Pipe Antifreeze Percentages by VolumeOperation Units with Aquazone Complete C ControlComplete C Control LED Code Fault Descriptions Units with HWR OptionSystem Test Service Aquazone Deluxe D Control LED IndicaESD Gravity Flow Method Troubleshooting Refrigerant ChargingAir Coil Fan Motor Removal Troubleshooting Fault Heating Cooling Possible Cause SolutionUnit Does Not Operate 50RHC,RVC,RHR,RHS,RVR,RVS,RDS START-UP Checklist II. START-UPHeating Cycle Analysis Cooling Cycle Analysis