ADJUSTING TABLE INSERT
WARNING: DISCONNECT MACHINE FROM POWER SOURCE.
Place a straight edge across the table at both ends of the table insert (Fig. 105). The table insert (A) should always be level with the table. If an adjustment is necessary, turn the adjusting screws (B). Four adjusting screws (B) are supplied in the table insert. The table insert is equipped with a convenient finger hole (C) for easy removal.
B
A
C B
Fig. 105
CHANGING THE SAW BLADE
1. WARNING: DISCONNECT MACHINE FROM POWER SOURCE.
2.NOTE: Two 7/8″ wrenches are supplied with the saw for changing the saw blade: a box end wrench (A) Fig. 107, and open end wrench (B). Use only 10″ saw blades rated for 3000 RPM or higher with 5/8″ arbor holes.
3.Remove table insert (C) Fig. 106, and raise saw blade to its maximum height.
4.Place the open end wrench (B) Fig. 106 on the flats of the saw arbor to keep the arbor from turning, and use wrench (A), to turn the arbor nut toward the front of the saw. Remove arbor nut, blade flange, and saw blade.
5.Assemble the new blade, making certain the teeth point down at the front of the saw table, and assemble outside blade flange and arbor nut. With wrench (B) Fig. 106, on the flats of the arbor to keep it from turning, tighten arbor nut by turning wrench (A) counterclockwise.
6.Replace table insert.
C
B
A
B
A
Fig. 106 | Fig. 107 |
34