Carrier 592-085 warranty Applications, Application Considerations, Undersizing, Oversizing

Page 4

APPLICATIONS (cont)

APPLICATION

CONSIDERATIONS

Installation instructions are shipped with all PTAC units. It is important that air conditioning systems be properly sized and installed for each application in order to achieve the desired temperature and humidity levels within the space to be conditioned. It is strongly recommended that a professional engineer match the PTAC units with the building structure and climate.

The following application considerations are all important in choosing the proper PTAC system for the building structure.

Undersizing

If a PTAC unit is undersized (cooling capacity is less than required capacity for an application), the unit will not be able to cool the space down to the desired tem- perature during very hot days. The result could be warm and humid or warm and dry conditioned space.

Oversizing

If a PTAC unit is oversized (cooling capacity is greater than required capacity for the specific application), the unit will cool the space down to the desired tempera- ture too quickly.

The unit will cycle on and off, however, dehumidifica- tion only takes place when the unit is operating. The result of this type of application in a hot and/or humid climate would be a cool, yet excessively humid, space.

Air Infiltration

Excessive air infiltration can intensify problems asso- ciated with undersizing or oversizing a PTAC unit. This can be the cause of insufficient cooling, dehumid- ification, or heating. Sources of air infiltration include vents, gaps around windows and doors, and improp- erly sealed floors, ceilings or wall joints.

4

Image 4
Contents Contents Architects and ENGINEERS’ ManualPage RETROFIT/REPLACEMENT Carrier WarrantyApplications NEW ConstructionApplications Application ConsiderationsUndersizing OversizingFan Cycle Switch Dual options Product Overview 52P and 52CProduct Features and Benefits 52P and 52C Quiet OperationMost Efficient Performance Efficient FAN MotorRemovable Front Panel NO-RUST Weather Last Wall Sleeve and Front PanelANTI-THEFT Knobs Product Features and Benefits TWO-PIECE Lifetime Indoor FilterWashable Vent AIR Filter BI-DIRECTIONAL Discharge GrilleBI-MOLDED Condenser Shroud Power Cord for 265-V UnitsSnow Baffle Easy Access to Chassis Temperature Limiter and Control KnobFan Cycle Switch Hidden ControlsEnhanced Copper Tubing Seamless BasepanCondensate Drain Valve Condensate Removal SystemHeat Pumps PAY Their OWN WAY Special FeaturesHow The Heat Pump Works Heat Pump Energy Savings Cooling Electric Premium Zone CapacityOrdering Data 52P and 52C NumberWall Thermostat Control RC,RP FACTORY-INSTALLED Options 52P and 52CCorrosion Protection CP,RP FIELD-INSTALLED Accessories 52P and 52C Wall SleevesInsulated Metal Wall Sleeves Wall Sleeve Molding KitFriedrich and ZoneAire Retro- fit Wall Sleeve Adapter Climate Master Wall Sleeve AdapterFIELD-INSTALLED Accessories 52P and 52C Outdoor GrillesAluminum Architectural Outdoor Grilles Louvered Polymeric Architectural Outdoor Grilles LouveredOutdoor Grille Selection Hardwire KitConduit Interface Kit Subbase Non-electrical subbaseLeveling legs Subbase Power Disconnect SwitchSubbase Fuse Kit Thermostats Digital Programmable ThermostatNon-Programmable Thermostat Manual Changeover Wall ThermostatSpeed Fan Control from Wall Thermostat Wall Thermostat Interface Retrofit KitThermostat Locking Cover Condensate Drain Kit Lateral Duct KitPower Vent with Power Door Kit Lateral Air DeflectorCurtain Deflector Security Door KitReplacement Filters Energy Management KitTypical Wall Installation Dimension Drawings and Installation Data NEW Construction208/230-V Units Dimension Drawings and Installation Data NEW Construction Typical Wall Installation Minimum Clearance for Indoor Outdoor Discharge AIR Typical Lateral Duct Installation 52P and 52C with Subbase Electrical ConnectionsWall Thermostat Connections Product Data 52P Model 52PQ 230/208-1-60Model 52PQ CAPACITY* Btuh52PQ Rev. Cycle 265Product Data 52P Model 52PC and PE 230/208-1-60Model 52PC and PE Product Data 52C Model 52CQ 230/208-1-60Cooling Heating 52CQ Rev. CycModel 52CQ Heating Cooling 52CQ Rev. CycleProduct Data 52C Model 52CE 230/208-1-60Heating† Cooling 52CEModel 52CE 52CE VoltsExpanded Ratings Data 52P and 52C Cooling PerformanceEvaporator entering air temp. 80 F Evap. air 260 CFM Evaporator entering air temp. 80 F Evap. air 350 CFMCooling Sensible Heat Factors SHF AT 80 F Indoor DB Cooling PerformanceEvaporator entering air temp. 80 F Evap. air 320 CFM Indoor Sound Data 52P and 52C Sound Data 52P and 52CSound Transmission Class STC = Wiring Diagrams 52P and 52C SLSWiring Diagrams 52P and 52C ‘R’ 24 VAC Output Power to Wall ‘C’ Common ThermostatPage Wiring Diagrams 52P and 52C Following are recommended wire sizes Maximum Length ftMaster Ptac Unit O C ’STAT Guide Specifications Hvac Guide SpecificationsGuide Specifications Page Typical Warranty CarrierCarrier Corporation Accessory List Accessory Form Number Part Number Description

592-085 specifications

The Carrier 592-085 is a leading-edge commercial air conditioning unit designed to provide efficient cooling solutions for various business environments. Known for its reliability, performance, and advanced technology, the Carrier 592-085 has become a popular choice among facility managers and HVAC professionals alike.

One of the primary features of the Carrier 592-085 is its impressive cooling capacity, which can handle large spaces with ease. The unit operates effectively in various climates, maintaining optimal indoor temperatures even during the hottest summer months. With a cooling capacity rating of 8.5 tons, it can accommodate medium to large commercial spaces, ensuring comfort for employees and customers.

The unit is equipped with advanced inverter technology, which allows it to adjust cooling output based on real-time demand. This not only enhances energy efficiency but also leads to significant cost savings over time. The inverter-driven compressor operates silently, reducing noise levels without compromising on performance.

In addition to its energy-efficient capabilities, the Carrier 592-085 features highly innovative refrigerant management. The unit uses R-410A refrigerant, which is environmentally friendly and contributes to reducing ozone depletion. This makes it an ideal choice for businesses looking to minimize their ecological footprint while maintaining effective cooling.

The Carrier 592-085 also boasts durable construction, with weather-resistant materials designed to withstand harsh external conditions. This ensures longevity and reduces maintenance needs in the long run. The unit's design also includes access panels for convenient servicing, making it easier for technicians to perform routine maintenance and repairs.

Moreover, the Carrier 592-085 is compatible with advanced building management systems, allowing for seamless integration into existing operations. Features such as remote monitoring and control provide users with the flexibility to manage their HVAC systems efficiently, enhancing overall operational efficiency.

In summary, the Carrier 592-085 stands out in the commercial air conditioning market due to its robust performance, energy efficiency, and advanced features. From its inverter technology to eco-friendly refrigerant usage and durable design, this unit provides a comprehensive solution for those seeking reliable cooling in commercial settings. It represents a smart investment for businesses that prioritize both comfort and sustainability.