Carrier 592-085 warranty

Page 53

P.Lateral Duct System (optional):

The lateral duct system shall allow one system to heat or cool two adjacent rooms, with up to a maximum of 30% of the discharge air being diverted to the adjoining room (a return air path must be provided from the adjoining room). The lateral duct kit consists of two main components, the plenum and the extension duct. In addition, the kit includes an adjustable chassis discharge air grille, adjustable wall register and decorative wall molding for duct extension.

The Lateral Duct system shall be adaptable for either right or left side ducting, with a maximum duct extension of 4 feet. The duct run must be straight and horizontal; no bends or turns.

Q.Accessories:

1.Insulated Polymer Wall Sleeve (P/N: SLEEVE-INSUL-1PK) shall be made from a molded polymer, with factory-installed Styro- foam insulation and a minimum flammability rating of UL94-5V. The sleeve surface shall be textured to prevent shine and hide scratches.

2.Deep Wall Metal Wall Sleeve (up to 28-in.) (P/N: SLEEVE-EXTxx-1PK) shall be a one- piece, extended wall sleeve, with factory installed insulation and deep wall baffles integrated.

3.Sleeve Molding (P/N: SLEEVE-MOLDING) shall trim the wall sleeve to the existing wall to hide wall joints and irregularities due to the sleeve opening.

4.Architectural Grille (P/N: GRILLE-PLA- xxxxx or GRILLE-ALU-xxxxx) shall be poly- meric for long durable life or painted alumi- num for a superior color match to the building.

5.Subbase (P/N: SUBBASE-xxxV-xxA) shall be pre-assembled from the factory and UL listed. Subbase options include:

Non-electrical subbase: The non-electrical subbase shall be pre-assembled and provides mechanical support and requires no wiring.

Electrical subbase: The electrical subbase shall be pre-assembled with factory-installed electrical junction box containing a receptacle for corded units.

Hardwired subbase: The hardwired electrical subbase shall be pre-assembled with factory installed electrical junction box containing 19 in. of flexible conduit (for a perfect fit to the unit) and all mating connections.

6.Leveling Legs (P/N: LEVELING-LEGS) shall attach easily to Carrier’s wall sleeve to provide accurate, adjustable leveling and support to units without a subbase.

7.Hardwire Kit (P/N: HARDWIRE-KIT) shall provide a permanent connection to the unit.

The hardwire kit mounts on the front right side of the unit and shall have 36 in. of flexible steel conduit and a Molex connector for easy connect/disconnect.

8.Conduit Interface Kit (P/N: CONDUIT-INTF- 4PK) shall provide wire connection to the unit to interface with field-supplied conduit.

9.Condensate Drain (P/N: DRAIN-KIT-4PK) kit shall be used internally or externally to route excess condensate to a drainage system. It can be field-installed on any Carrier wall sleeve. The drain kit shall be attached to the exterior right or left side of the wall sleeve for external draining or may be mounted to the bottom of the wall sleeve for internal draining.

10.Lateral Duct (P/N: LATERAL-DUCT) kit shall include an adapter plenum, extension duct, wall register and wall molding. The lat- eral duct system allows one system to heat or cool two adjacent rooms, by directing up to 30% of the airflow to the adjacent room. See section 4.0 for detailed specification.

11.Energy Management (P/N: EM-KIT) shall allow individual units to be turned on and off from a remote location or by a motion sensing device. This kit interfaces to most energy man- agement systems.

12.Lateral Air Deflector (P/N: DEFLECTOR- 1PK) shall allow right or left air distribution from the chassis. Lateral air deflectors are rec- ommended for units mounted in a corner or off-center in a room.

13.Curtain Deflector (P/N: CURTDEL-52CP- 1PK) shall prevent curtains from being blown into the discharge air.

14.Security door (P/N: SECURITY-DOOR) kit shall prevent unauthorized access to the unit’s heating and cooling controls and prevents tampering with units in public locations and institutions. The security door shall include two matching keys and keys shall be common to all Carrier Security Door kits.

15.Wall Thermostats (P/N: TSTATCCBxx01-B) shall operate with 24 VAC, be digital and non-programmable, easy-to-use and provide maximum guest comfort.

16.Sleeve Molding (P/N: SLEEVE-MOLDING) shall trim the wall sleeve to the existing wall to hide wall joints and irregularities due to the sleeve opening.

17.Power Fresh Air Vent (P/N: PWR-VENT- DOORxxx) kit shall provide approximately 95 cfm of outdoor air for ventilation into the room. The kit shall have an automatically door that opens when the fan is on and closes when the fan is off.

53

Image 53
Contents Architects and ENGINEERS’ Manual ContentsPage Carrier Warranty RETROFIT/REPLACEMENTApplications NEW ConstructionApplication Considerations ApplicationsUndersizing OversizingProduct Overview 52P and 52C Fan Cycle Switch Dual optionsQuiet Operation Product Features and Benefits 52P and 52CMost Efficient Performance Efficient FAN MotorANTI-THEFT Knobs NO-RUST Weather Last Wall Sleeve and Front PanelRemovable Front Panel TWO-PIECE Lifetime Indoor Filter Product Features and BenefitsWashable Vent AIR Filter BI-DIRECTIONAL Discharge GrilleSnow Baffle Power Cord for 265-V UnitsBI-MOLDED Condenser Shroud Temperature Limiter and Control Knob Easy Access to ChassisFan Cycle Switch Hidden ControlsSeamless Basepan Enhanced Copper TubingCondensate Drain Valve Condensate Removal SystemHow The Heat Pump Works Special FeaturesHeat Pumps PAY Their OWN WAY Cooling Electric Premium Zone Capacity Heat Pump Energy SavingsNumber Ordering Data 52P and 52CCorrosion Protection CP,RP FACTORY-INSTALLED Options 52P and 52CWall Thermostat Control RC,RP Wall Sleeves FIELD-INSTALLED Accessories 52P and 52CWall Sleeve Molding Kit Insulated Metal Wall SleevesFriedrich and ZoneAire Retro- fit Wall Sleeve Adapter Climate Master Wall Sleeve AdapterOutdoor Grilles FIELD-INSTALLED Accessories 52P and 52CAluminum Architectural Outdoor Grilles Louvered Polymeric Architectural Outdoor Grilles LouveredConduit Interface Kit Hardwire KitOutdoor Grille Selection Non-electrical subbase SubbaseSubbase Fuse Kit Subbase Power Disconnect SwitchLeveling legs Digital Programmable Thermostat ThermostatsNon-Programmable Thermostat Manual Changeover Wall ThermostatThermostat Locking Cover Wall Thermostat Interface Retrofit KitSpeed Fan Control from Wall Thermostat Lateral Duct Kit Condensate Drain KitLateral Air Deflector Power Vent with Power Door KitCurtain Deflector Security Door KitEnergy Management Kit Replacement Filters208/230-V Units Dimension Drawings and Installation Data NEW ConstructionTypical Wall Installation Dimension Drawings and Installation Data NEW Construction Typical Wall Installation Minimum Clearance for Indoor Outdoor Discharge AIR Typical Lateral Duct Installation Electrical Connections 52P and 52C with SubbaseWall Thermostat Connections Model 52PQ 230/208-1-60 Product Data 52PCAPACITY* Btuh Model 52PQ52PQ Rev. Cycle 265Model 52PC and PE 230/208-1-60 Product Data 52PModel 52PC and PE Model 52CQ 230/208-1-60 Product Data 52CCooling Heating 52CQ Rev. CycHeating Cooling 52CQ Rev. Cycle Model 52CQModel 52CE 230/208-1-60 Product Data 52CHeating† Cooling 52CE52CE Volts Model 52CECooling Performance Expanded Ratings Data 52P and 52CEvaporator entering air temp. 80 F Evap. air 260 CFM Evaporator entering air temp. 80 F Evap. air 350 CFMEvaporator entering air temp. 80 F Evap. air 320 CFM Cooling PerformanceCooling Sensible Heat Factors SHF AT 80 F Indoor DB Sound Transmission Class STC = Sound Data 52P and 52CIndoor Sound Data 52P and 52C SLS Wiring Diagrams 52P and 52C‘R’ 24 VAC Output Power to Wall ‘C’ Common Thermostat Wiring Diagrams 52P and 52CPage Wiring Diagrams 52P and 52C Maximum Length ft Following are recommended wire sizesMaster Ptac Unit O C ’STAT Hvac Guide Specifications Guide SpecificationsGuide Specifications Page Carrier Typical WarrantyCarrier Corporation Accessory Form Number Part Number Description Accessory List

592-085 specifications

The Carrier 592-085 is a leading-edge commercial air conditioning unit designed to provide efficient cooling solutions for various business environments. Known for its reliability, performance, and advanced technology, the Carrier 592-085 has become a popular choice among facility managers and HVAC professionals alike.

One of the primary features of the Carrier 592-085 is its impressive cooling capacity, which can handle large spaces with ease. The unit operates effectively in various climates, maintaining optimal indoor temperatures even during the hottest summer months. With a cooling capacity rating of 8.5 tons, it can accommodate medium to large commercial spaces, ensuring comfort for employees and customers.

The unit is equipped with advanced inverter technology, which allows it to adjust cooling output based on real-time demand. This not only enhances energy efficiency but also leads to significant cost savings over time. The inverter-driven compressor operates silently, reducing noise levels without compromising on performance.

In addition to its energy-efficient capabilities, the Carrier 592-085 features highly innovative refrigerant management. The unit uses R-410A refrigerant, which is environmentally friendly and contributes to reducing ozone depletion. This makes it an ideal choice for businesses looking to minimize their ecological footprint while maintaining effective cooling.

The Carrier 592-085 also boasts durable construction, with weather-resistant materials designed to withstand harsh external conditions. This ensures longevity and reduces maintenance needs in the long run. The unit's design also includes access panels for convenient servicing, making it easier for technicians to perform routine maintenance and repairs.

Moreover, the Carrier 592-085 is compatible with advanced building management systems, allowing for seamless integration into existing operations. Features such as remote monitoring and control provide users with the flexibility to manage their HVAC systems efficiently, enhancing overall operational efficiency.

In summary, the Carrier 592-085 stands out in the commercial air conditioning market due to its robust performance, energy efficiency, and advanced features. From its inverter technology to eco-friendly refrigerant usage and durable design, this unit provides a comprehensive solution for those seeking reliable cooling in commercial settings. It represents a smart investment for businesses that prioritize both comfort and sustainability.