GUIDE SPECIFICATIONS

PACKAGED TERMINAL COOLING UNIT WITH HEAT PUMP OR ELECTRIC HEATING

HVAC Guide Specifications

Size Range: Cooling: 6,900 to 15,100 Btuh Heating: 6,000 to 14,100 Btuh Heat Pump

6,400 to 17,000 Btuh Electric Carrier Model Numbers:

52PC Premier Series, Cooling Only

52PE Premier Series, Cooling with Electric Heat

52PQ Premier Series, Heat Pump with Electric Heat

52CE Comfort Series, Cooling with Electric Heat

52CQ Comfort Series, Heat Pump with Electric Heat

Part 1 — General

1.01 SYSTEM DESCRIPTION

Single piece, thru-the-wall electrically controlled unit using hermetic rotary compressor for cooling and heat pump or electric resistance heat, as shown on the con- tract drawings.

A.Insulated Polymer Wall Sleeve:

Wall sleeve shall provide excellent thermal insula- tion, be textured to hide scratches and prevent shine, will have superior outdoor noise absorption and shall be corrosion free for the life of the prod- uct. The Wall Sleeve must have dimensions of

42 in. width x 16 in. height x 147/8 in. depth and be shipped with a rear weather barrier installed.

B.Wall Sleeve Molding:

Molding shall trim the wall sleeve to the existing wall, to hide wall imperfections and irregularities in the wall opening.

C.Outdoor Polymer Louvered Grille:

Outdoor grille shall resist corrosion, breakage and match the color specified on drawing schedule and specifications.

D.Subbase:

Subbase will support the wall sleeve when it extends into the room more than 4 inches. Subbase must come from the factory pre-assembled, with a built in receptacle (size as specified on drawing schedule and specifications) or with factory- installed hardwire, pre-sized for an exact fit to the unit.

1.02 QUALITY ASSURANCE

System shall be approved and certified by UL and UL, Canada. Chassis capacity and efficiency perfor- mance shall be certified in accordance with ARI standard 310/380. Chassis shall meet ASHRAE Standard 90.1 for minimum energy efficiency.

Chassis shall meet the New York City Department of Building, Material and Equipment acceptance require- ment (MEA).

1.03DELIVERY, STORAGE, AND HANDLING

A.The packaging of the chassis shall be sufficient to protect the chassis from damage during shipment via an enclosed truck. Chassis must also be able to withstand an impact force of 10 g’s and a random continuous force of 1g, during shipping.

B.Chassis, wall sleeves, and grilles shall be shipped in separate cartons. Universal handling instructions shall be defined and visible on the carton, from front, back and sides.

C.Chassis shall be capable of withstanding tempera- tures from –40 F to 155 F, at 5 to 95 percent RH, non-condensing, during shipment and storage, without component failure.

D.Unit shall be stored and handled per manufacturer’s recommendations.

Part 2 — Products

2.01EQUIPMENT

A.General:

Factory-assembled, single-piece heating and/or cooling unit. Contained within the unit enclosure shall be compressor, coils, fans and fan motor, heat- ing means, controls, all wiring and piping, and a full refrigerant charge (R-22).

Packaged Terminal Air Conditioners shall be of the sizes and capacities as shown on the contract draw- ing schedule and in the specifications.

B.Chassis:

The chassis shall be a factory-assembled, single- piece heating and/or cooling unit, that is simple to install and operate. Just slide the chassis into a wall sleeve, plug it into an outlet, and operate after installation. The chassis dimensions shall not exceed 42 in. wide and 16 in. high with room cabi- net in place. The chassis shall consist of the follow- ing functional sections and components:

1.Operating Characteristics:

Chassis shall be capable of starting and run- ning at 115 F ambient outdoor temperature per maximum load criteria of ARI Standard 310/ 380.

2.Electrical:

Chassis shall be equipped with a 58 in. power cord for 208/230 v models or a 15 in. power cord for 265 v models. The chassis current draw shall be specified on the chassis name- plate and match electrical requirements speci- fied on the Contract drawing schedule and specifications. The power cord plug configura- tion shall conform to NEMA standards and the rating shall support the current draw of the electric resistance heater.

For 265 v installations, UL codes require the use of an electrical equipped subbase for power cord usage or hardwire conduit for non- corded installations.

C.Airflow System:

The airflow system shall consist of one permanent split-capacitor, direct-drive permanently lubri- cated, two-speed fan motor for the indoor and out- door fans. The outdoor fan shall be a dynamically balanced, corrosion-resistant polymer multi-blade

51

Image 51
Contents Architects and ENGINEERS’ Manual ContentsPage NEW Construction RETROFIT/REPLACEMENTCarrier Warranty ApplicationsOversizing ApplicationsApplication Considerations UndersizingProduct Overview 52P and 52C Fan Cycle Switch Dual optionsEfficient FAN Motor Product Features and Benefits 52P and 52CQuiet Operation Most Efficient PerformanceNO-RUST Weather Last Wall Sleeve and Front Panel Removable Front PanelANTI-THEFT Knobs BI-DIRECTIONAL Discharge Grille Product Features and BenefitsTWO-PIECE Lifetime Indoor Filter Washable Vent AIR FilterPower Cord for 265-V Units BI-MOLDED Condenser ShroudSnow Baffle Hidden Controls Easy Access to ChassisTemperature Limiter and Control Knob Fan Cycle SwitchCondensate Removal System Enhanced Copper TubingSeamless Basepan Condensate Drain ValveSpecial Features Heat Pumps PAY Their OWN WAYHow The Heat Pump Works Cooling Electric Premium Zone Capacity Heat Pump Energy SavingsNumber Ordering Data 52P and 52CFACTORY-INSTALLED Options 52P and 52C Wall Thermostat Control RC,RPCorrosion Protection CP,RP Wall Sleeves FIELD-INSTALLED Accessories 52P and 52CClimate Master Wall Sleeve Adapter Insulated Metal Wall SleevesWall Sleeve Molding Kit Friedrich and ZoneAire Retro- fit Wall Sleeve AdapterPolymeric Architectural Outdoor Grilles Louvered FIELD-INSTALLED Accessories 52P and 52COutdoor Grilles Aluminum Architectural Outdoor Grilles LouveredHardwire Kit Outdoor Grille SelectionConduit Interface Kit Non-electrical subbase SubbaseSubbase Power Disconnect Switch Leveling legsSubbase Fuse Kit Manual Changeover Wall Thermostat ThermostatsDigital Programmable Thermostat Non-Programmable ThermostatWall Thermostat Interface Retrofit Kit Speed Fan Control from Wall ThermostatThermostat Locking Cover Lateral Duct Kit Condensate Drain KitSecurity Door Kit Power Vent with Power Door KitLateral Air Deflector Curtain DeflectorEnergy Management Kit Replacement FiltersDimension Drawings and Installation Data NEW Construction Typical Wall Installation208/230-V Units Dimension Drawings and Installation Data NEW Construction Typical Wall Installation Minimum Clearance for Indoor Outdoor Discharge AIR Typical Lateral Duct Installation Electrical Connections 52P and 52C with SubbaseWall Thermostat Connections Model 52PQ 230/208-1-60 Product Data 52P265 Model 52PQCAPACITY* Btuh 52PQ Rev. CycleModel 52PC and PE 230/208-1-60 Product Data 52PModel 52PC and PE Rev. Cyc Product Data 52CModel 52CQ 230/208-1-60 Cooling Heating 52CQHeating Cooling 52CQ Rev. Cycle Model 52CQ52CE Product Data 52CModel 52CE 230/208-1-60 Heating† Cooling52CE Volts Model 52CEEvaporator entering air temp. 80 F Evap. air 350 CFM Expanded Ratings Data 52P and 52CCooling Performance Evaporator entering air temp. 80 F Evap. air 260 CFMCooling Performance Cooling Sensible Heat Factors SHF AT 80 F Indoor DBEvaporator entering air temp. 80 F Evap. air 320 CFM Sound Data 52P and 52C Indoor Sound Data 52P and 52CSound Transmission Class STC = SLS Wiring Diagrams 52P and 52C‘R’ 24 VAC Output Power to Wall ‘C’ Common Thermostat Wiring Diagrams 52P and 52CPage Wiring Diagrams 52P and 52C Maximum Length ft Following are recommended wire sizesMaster Ptac Unit O C ’STAT Hvac Guide Specifications Guide SpecificationsGuide Specifications Page Carrier Typical WarrantyCarrier Corporation Accessory Form Number Part Number Description Accessory List

592-085 specifications

The Carrier 592-085 is a leading-edge commercial air conditioning unit designed to provide efficient cooling solutions for various business environments. Known for its reliability, performance, and advanced technology, the Carrier 592-085 has become a popular choice among facility managers and HVAC professionals alike.

One of the primary features of the Carrier 592-085 is its impressive cooling capacity, which can handle large spaces with ease. The unit operates effectively in various climates, maintaining optimal indoor temperatures even during the hottest summer months. With a cooling capacity rating of 8.5 tons, it can accommodate medium to large commercial spaces, ensuring comfort for employees and customers.

The unit is equipped with advanced inverter technology, which allows it to adjust cooling output based on real-time demand. This not only enhances energy efficiency but also leads to significant cost savings over time. The inverter-driven compressor operates silently, reducing noise levels without compromising on performance.

In addition to its energy-efficient capabilities, the Carrier 592-085 features highly innovative refrigerant management. The unit uses R-410A refrigerant, which is environmentally friendly and contributes to reducing ozone depletion. This makes it an ideal choice for businesses looking to minimize their ecological footprint while maintaining effective cooling.

The Carrier 592-085 also boasts durable construction, with weather-resistant materials designed to withstand harsh external conditions. This ensures longevity and reduces maintenance needs in the long run. The unit's design also includes access panels for convenient servicing, making it easier for technicians to perform routine maintenance and repairs.

Moreover, the Carrier 592-085 is compatible with advanced building management systems, allowing for seamless integration into existing operations. Features such as remote monitoring and control provide users with the flexibility to manage their HVAC systems efficiently, enhancing overall operational efficiency.

In summary, the Carrier 592-085 stands out in the commercial air conditioning market due to its robust performance, energy efficiency, and advanced features. From its inverter technology to eco-friendly refrigerant usage and durable design, this unit provides a comprehensive solution for those seeking reliable cooling in commercial settings. It represents a smart investment for businesses that prioritize both comfort and sustainability.