Graco 395/490/495/595 important safety instructions Maintenance, Activity Interval

Page 28

Maintenance

Maintenance

Routine maintenance is important to ensure proper operation of your sprayer. Maintenance includes performing routine actions which keep your sprayer in operation and prevents trouble in the future.

Activity

Interval

 

 

Inspect/clean sprayer filter, fluid inlet strainer, and gun

Daily or each time you spray

filter.

 

 

 

Inspect motor shield vents for blockage.

Daily or each time you spray

 

 

Fill TSL by adding through TSL fill point.

Daily or each time you spray

 

 

Inspect motor brushes for wear. Brushes must be 1/2 in.

Every 1000 gallons (3785 liters)

(13mm) minimum length. NOTE: Brushes do not wear at

 

the same rate on both sides of motor. Check both brushes.

 

 

 

Check sprayer stall.

Every 1000 gallons (3785 liters)

With sprayer gun NOT triggered, sprayer motor should stall

 

and not restart until gun is triggered again.

 

If sprayer starts again with gun NOT triggered, inspect

 

pump for internal/external leaks and check prime valve for

 

leaks.

 

 

 

Throat packing adjustment

As necessary based on usage

When pump packing begins to leak after extended use,

 

tighten packing nut down until leakage stops or lessens.

 

This allows approximately 100 gallons of additional

 

operation before a repacking is required. Packing nut can

 

be tightened without 0-ring removal.

 

 

 

28

334530A

Image 28
Contents Related Manuals Contractor/FTxSG3 334599Contents Models Hi-BoyStand Lo-Boy ModelGrounding Extension CordsFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Component Identification Stand ModelsLo-Boy Models Hi-Boy Models Hi-Boy Models Power Requirements GroundingExtension Cords PailsPressure Relief Procedure Trigger Lock Setup 334530ATi24638a Make certain ON/OFF switch is OFF Setup Perform Pressure Relief Procedure Startup20 s Spray Tip Installation Perform Pressure Relief Procedure,Operation SprayClear Tip Clog Digital Display Pressure Display Perform Pressure Relief Procedure,Stored Data Display Ti2824a Cleanup Fast Flush Drain TubeFast Flush Hose and Gun To flush drain tube and pump turn prime valve downIf flushing with water, flush again with Maintenance Activity IntervalMechanical/Fluid Flow TroubleshootingRefer to this column Properly installed to allow full Possible during priming Perform Pressure Relief Procedure, Error Code MessagesElectrical Problem What to Check How to check System see Pressure ReliefDisplays Code 03 message Step Ohms Motor thermal device When cool, correct cause Sprayer Will Not Run Sprayer Will Not RunOhms Troubleshooting Procedure Sprayer Will Not Shut Off395/490/495 Stand Sprayers See132 Ref. Part Description 395/490/495 Stand Sprayers Parts ListQty 395/490/495/595 Lo-Boy Sprayers 117 132 395/490/495/595 Lo-Boy Sprayers Parts List 395/490/495/595 Hi-Boy Sprayers 117 395/490/495/595 Hi-Boy Sprayers Parts List Ref. PartAccessories and Labels Alert Control Box Control Box Parts List GrommetControl Box Wiring Diagrams 120V, US/Japan110V, UK Technical Specifications 395/490/495/595Noise** dBa @ 70 psi 0.48 MPa, 4.8 bar Graco Standard Warranty For Graco Canada CustomersGraco Information International Offices Belgium, China, Japan, Korea