Graco 395/490/495/595 important safety instructions Make certain ON/OFF switch is OFF

Page 17

Setup

8.Make certain ON/OFF switch is OFF.

ti24586a

9.Plug power supply cord into a properly grounded electrical outlet.

ti24651a

10. Turn prime valve down.

ti24608a

334530A

11.Place fluid intake with drain tube in grounded metal pail partially filled with flushing fluid. See Grounding, page 12.

NOTE: New sprayers are shipped with storage fluid that must be flushed out

with mineral spirits prior to using the

sprayer.

Check flushing fluid for compatibility with material that is to be sprayed. A secondary flush with a compatible fluid may be necessary. Water for latex paint or mineral spirits for oil-based paint.

ti24640a

12.Turn pressure control to OFF.

13.Turn ON/OFF switch to ON position.

14.Turn prime valve horizontal. Disengage trigger lock.

15.Turn pressure control to Prime/Slow.

16.Hold a metal part of the gun firmly to a grounded metal pail. Trigger gun and flush for one minute.

17.Turn ON/OFF switch to OFF position.

18.Engage trigger lock.

19.After flushing storage fluid out of the sprayer empty pail. Replace fluid intake with drain tube in grounded metal pail partially filled with flushing fluid. Use water to flush water-based paint or mineral spirits to flush oil-based paint.

20.Turn ON/OFF switch to ON position.

21.Turn prime valve horizontal. Disengage trigger lock.

17

Image 17
Contents Contractor/FTx Related ManualsSG3 334599Contents Hi-Boy ModelsStand Lo-Boy ModelExtension Cords GroundingFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Stand Models Component IdentificationLo-Boy Models Hi-Boy Models Hi-Boy Models Grounding Power RequirementsExtension Cords PailsPressure Relief Procedure Trigger Lock 334530A SetupTi24638a Make certain ON/OFF switch is OFF Setup Startup Perform Pressure Relief Procedure20 s Perform Pressure Relief Procedure, Spray Tip InstallationOperation SprayClear Tip Clog Stored Data Display Pressure Display Perform Pressure Relief Procedure,Digital Display Ti2824a Fast Flush Drain Tube CleanupTo flush drain tube and pump turn prime valve down Fast Flush Hose and GunIf flushing with water, flush again with Activity Interval MaintenanceRefer to this column TroubleshootingMechanical/Fluid Flow Properly installed to allow full Possible during priming Electrical Error Code MessagesPerform Pressure Relief Procedure, System see Pressure Relief Problem What to Check How to checkDisplays Code 03 message Step Ohms Motor thermal device When cool, correct cause Sprayer Will Not Run Sprayer Will Not RunOhms Sprayer Will Not Shut Off Troubleshooting ProcedureSee 395/490/495 Stand Sprayers132 Qty 395/490/495 Stand Sprayers Parts ListRef. Part Description 395/490/495/595 Lo-Boy Sprayers 117 132 395/490/495/595 Lo-Boy Sprayers Parts List 395/490/495/595 Hi-Boy Sprayers 117 Ref. Part 395/490/495/595 Hi-Boy Sprayers Parts ListAlert  Accessories and LabelsControl Box Grommet Control Box Parts ListControl Box 120V, US/Japan Wiring Diagrams110V, UK 395/490/495/595 Technical SpecificationsNoise** dBa @ 70 psi 0.48 MPa, 4.8 bar For Graco Canada Customers Graco Standard WarrantyInternational Offices Belgium, China, Japan, Korea Graco Information