| Troubleshooting | ||
|
|
|
|
Problem | What to Check |
| How to check |
|
|
| |
Sprayer does not run at all | Motor is hot or there is a fault in the | Allow sprayer to cool. If sprayer runs | |
AND | motor thermal device. | when cool, correct cause of | |
| overheating. Keep sprayer in cooler | ||
Displays Code 06 message |
| ||
| location with good ventilation. Make | ||
OR |
| sure motor air intake is not blocked. If | |
| sprayer still does not run, replace | ||
Control board status light blinks 6 |
| ||
| motor. | ||
times repeatedly |
| NOTE: Motor must be cooled down | |
|
| ||
|
| for the test. | |
|
| 1. | Check thermal device |
|
|
| connector (yellow wires) |
|
|
| at control board. |
|
| 2. | Disconnect thermal device |
|
|
| connector from control board |
|
|
| socket. Make sure contacts are |
|
|
| clean and secure. Measure |
|
|
| resistance of the thermal |
|
|
| device. If reading is not correct, |
|
|
| replace motor. |
|
| Check Motor Thermal Switch: | |
|
| Unplug thermal wires. Set meter to | |
|
| ohms. Meter should read 100k ohms. | |
|
| 3. | Reconnect thermal device |
|
|
| connector to control board |
|
|
| socket. Connect power, turn |
|
|
| sprayer ON and control knob 1/2 |
|
|
| turn clockwise. If sprayer does |
|
|
| not run, replace control board. |
|
|
| |
Basic electrical problems | Motor leads are securely fastened | Replace loose terminals; crimp to | |
| and properly mated | leads. Be sure terminal are firmly | |
|
| connected. | |
|
| Clean circuit board terminals. | |
|
| Securely reconnect leads. | |
|
|
| |
| For loose motor brush lead | Tighten terminal screws. Replace | |
| connections and terminals. | brushes if leads are damaged. | |
|
|
| |
| Brushes must be 1/2 in. [13mm] | Replace brushes. | |
| minimum length. NOTE: Brushes do |
|
|
| not wear at the same rate on both |
|
|
| sides of motor. Check both brushes. |
|
|
|
|
| |
| Broken or misaligned motor brush | Replace spring if broken. Realign | |
| springs. Rolled portion of spring must | spring with brush. | |
| rest squarely on top of brush. |
|
|
|
|
| |
| Motor brushes may be binding in | Clean brush holders. Remove carbon | |
| brush holders. | with small cleaning brush. Align brush | |
|
| leads with slot in brush holder to | |
|
| assure free vertical brush movement. | |
|
|
| |
| Motor armature commutator for burn | Remove motor and have motor shop | |
| spots, gouges or extreme roughness. | resurface commutator if possible. | |
|
|
|
|