Graco 395/490/495/595 Troubleshooting, Mechanical/Fluid Flow, Refer to this column

Page 29

Troubleshooting

Troubleshooting

Mechanical/Fluid Flow

1.Follow Pressure Relief Procedure, page 13, before checking or repairing.

2.Check all possible problems and causes before disassembling the unit.

 

What to Check

What to Do

 

If check is OK, go to next

When check is not OK,

Problem

check

refer to this column

 

 

 

For units with display:

Fault condition exists.

Determine fault correction from

E=0X is displayed.

 

Electrical, page 32.

For units with no display: Control

 

 

board status light is blinking or the

 

 

light is off and there is power to the

 

 

sprayer.

 

 

 

 

 

Pump output is low

Spray tip worn.

Follow Pressure Relief Procedure,

 

 

page 13, then replace tip. See

 

 

separate gun or tip manual.

 

 

 

 

Spray tip clogged.

Relieve pressure. Check and clean

 

 

spray tip.

 

 

 

 

Paint supply.

Refill and reprime pump.

 

 

 

 

Intake strainer clogged.

Remove and clean, then reinstall.

 

 

 

 

Intake valve ball and piston ball are

Remove intake valve and clean.

 

not seating properly.

Check balls and seats for nicks;

 

 

replace if necessary. See pump

 

 

manual. Strain paint before using to

 

 

remove particles that could clog

 

 

pump.

 

 

 

 

Fluid filter or tip filter is clogged or

Clean filter.

 

dirty.

 

 

 

 

 

Prime valve leaking.

Follow Pressure Relief Procedure,

 

 

page 13, then repair prime valve.

 

 

 

 

Verify pump does not continue to

Service pump. See pump manual.

 

stroke when gun trigger is released.

 

 

(Prime valve not leaking.)

 

 

 

 

 

Leaking around throat packing nut

Replace packings. See pump manual.

 

which may indicate worn or damaged

Also check piston valve seat for

 

packings.

hardened paint or nicks and replace if

 

 

necessary. Tighten packing

 

 

nut/wet-cup.

 

 

 

334530A

29

Image 29 Contents
Contractor/FTx Related ManualsSG3 334599Contents Hi-Boy ModelsStand Lo-Boy ModelExtension Cords GroundingFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Stand Models Component IdentificationLo-Boy Models Hi-Boy Models Hi-Boy Models Grounding Power RequirementsExtension Cords PailsPressure Relief Procedure Trigger Lock 334530A SetupTi24638a Make certain ON/OFF switch is OFF Setup Startup Perform Pressure Relief Procedure20 s Perform Pressure Relief Procedure, Spray Tip InstallationOperation SprayClear Tip Clog Stored Data Display Pressure Display Perform Pressure Relief Procedure,Digital Display Ti2824a Fast Flush Drain Tube CleanupTo flush drain tube and pump turn prime valve down Fast Flush Hose and GunIf flushing with water, flush again with Activity Interval MaintenanceRefer to this column TroubleshootingMechanical/Fluid Flow Properly installed to allow full Possible during priming Electrical Error Code MessagesPerform Pressure Relief Procedure, System see Pressure Relief Problem What to Check How to checkDisplays Code 03 message Step Ohms Motor thermal device When cool, correct cause Sprayer Will Not Run Sprayer Will Not RunOhms Sprayer Will Not Shut Off Troubleshooting ProcedureSee 395/490/495 Stand Sprayers132 Qty 395/490/495 Stand Sprayers Parts ListRef. Part Description 395/490/495/595 Lo-Boy Sprayers 117 132 395/490/495/595 Lo-Boy Sprayers Parts List 395/490/495/595 Hi-Boy Sprayers 117 Ref. Part 395/490/495/595 Hi-Boy Sprayers Parts ListAlert  Accessories and LabelsControl Box Grommet Control Box Parts ListControl Box 120V, US/Japan Wiring Diagrams110V, UK 395/490/495/595 Technical SpecificationsNoise** dBa @ 70 psi 0.48 MPa, 4.8 bar For Graco Canada Customers Graco Standard WarrantyInternational Offices Belgium, China, Japan, Korea Graco Information