Operation
5.To flush drain tube and pump turn prime valve down.
ti24713a |
6.Turn pressure control to Fast Flush operate until the pump runs steady and flushing fluid appears in the waste pail.
Fast Flush Hose and Gun
7.To flush airless hose and spray gun, turn prime valve horizontal.
26
8.Hold gun against waste pail. Disengage trigger lock. Trigger gun and turn pressure control to Fast Flush operate until the pump runs steady and flushing fluid appears.
ti24991a |
9.Stop triggering gun.
10.Raise fluid intake above flushing fluid.
ti24714a |
334530A |