Graco 395/490/495/595 important safety instructions Grounding, Extension Cords

Page 4

Warnings

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

GROUNDING

This product must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric shock by providing an escape wire for the electric current. This product is equipped with a cord having a grounding wire with an appropriate grounding plug. The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Improper installation of the grounding plug is able to result in a risk of electric shock.

When repair or replacement of the cord or plug is required, do not connect the grounding wire to either flat blade terminal.

The wire with insulation having an outer surface that is green with or without yellow stripes is the grounding wire.

Check with a qualified electrician or serviceman when the grounding instructions are not completely understood, or when in doubt as to whether the product is properly grounded.

Do not modify the plug provided; if it does not fit the outlet, have the proper outlet installed by a qualified electrician.

This product is for use on a nominal 120V or 230V circuit and has a grounding plug similar to the plugs illustrated below.

120V US

230V

110V UK

ti24583a

Only connect the product to an outlet having the same configuration as the plug.

Do not use an adapter with this product.

Extension Cords:

Use only a 3-wire extension cord that has a grounding plug and a grounding receptacle that accepts the plug on the product.

Make sure your extension cord is not damaged. If an extension cord is necessary use 12 AWG (2.5mm2) minimum to carry the current that the product draws.

An undersized cord results in a drop in line voltage and loss of power and overheating.

4

334530A

Image 4
Contents Related Manuals Contractor/FTxSG3 334599Contents Models Hi-BoyStand Lo-Boy ModelGrounding Extension CordsFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Component Identification Stand ModelsLo-Boy Models Hi-Boy Models Hi-Boy Models Power Requirements GroundingExtension Cords PailsPressure Relief Procedure Trigger Lock Setup 334530ATi24638a Make certain ON/OFF switch is OFF Setup Perform Pressure Relief Procedure Startup20 s Spray Tip Installation Perform Pressure Relief Procedure,Operation SprayClear Tip Clog Digital Display Pressure Display Perform Pressure Relief Procedure,Stored Data Display Ti2824a Cleanup Fast Flush Drain TubeFast Flush Hose and Gun To flush drain tube and pump turn prime valve downIf flushing with water, flush again with Maintenance Activity IntervalMechanical/Fluid Flow TroubleshootingRefer to this column Properly installed to allow full Possible during priming Perform Pressure Relief Procedure, Error Code MessagesElectrical Problem What to Check How to check System see Pressure ReliefDisplays Code 03 message Step Ohms Motor thermal device When cool, correct cause Sprayer Will Not Run Sprayer Will Not RunOhms Troubleshooting Procedure Sprayer Will Not Shut Off395/490/495 Stand Sprayers See132 Ref. Part Description 395/490/495 Stand Sprayers Parts ListQty 395/490/495/595 Lo-Boy Sprayers 117 132 395/490/495/595 Lo-Boy Sprayers Parts List 395/490/495/595 Hi-Boy Sprayers 117 395/490/495/595 Hi-Boy Sprayers Parts List Ref. PartAccessories and Labels Alert Control Box Control Box Parts List GrommetControl Box Wiring Diagrams 120V, US/Japan110V, UK Technical Specifications 395/490/495/595Noise** dBa @ 70 psi 0.48 MPa, 4.8 bar Graco Standard Warranty For Graco Canada CustomersGraco Information International Offices Belgium, China, Japan, Korea