Graco 395/490/495/595 important safety instructions Startup, Perform Pressure Relief Procedure

Page 19

 

 

Startup

Startup

 

1.

Perform Pressure Relief Procedure,

 

 

page 13.

 

2.

Turn pressure control to lowest

 

 

pressure.

 

 

ti24953a

 

3.

Turn ON/OFF switch to ON position.

 

 

 

ti24646a

 

7.

Hold gun against grounded metal waste

 

 

pail. Trigger gun until paint appears.

 

ti24644a

 

4.

Place fluid intake in paint pail. Place

 

 

drain tube in waste pail.

 

5.

Turn pressure control to Fast Flush to

 

 

start motor. Allow paint to circulate

 

 

through drain tube for 15 seconds.

 

 

15 s

 

 

ti24954a

1 m

6.

Turn prime valve horizontal. Disengage

 

trigger lock.

ti24647a

 

 

334530A

19

Image 19
Contents 334599 Related ManualsContractor/FTx SG3Contents Model ModelsHi-Boy Stand Lo-BoyExtension Cords GroundingFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Stand Models Component IdentificationLo-Boy Models Hi-Boy Models Hi-Boy Models Pails Power RequirementsGrounding Extension CordsPressure Relief Procedure Trigger Lock 334530A SetupTi24638a Make certain ON/OFF switch is OFF Setup Startup Perform Pressure Relief Procedure20 s Spray Spray Tip InstallationPerform Pressure Relief Procedure, OperationClear Tip Clog Digital Display Pressure Display Perform Pressure Relief Procedure,Stored Data Display Ti2824a Fast Flush Drain Tube CleanupTo flush drain tube and pump turn prime valve down Fast Flush Hose and GunIf flushing with water, flush again with Activity Interval MaintenanceMechanical/Fluid Flow TroubleshootingRefer to this column Properly installed to allow full Possible during priming Perform Pressure Relief Procedure, Error Code MessagesElectrical System see Pressure Relief Problem What to Check How to checkDisplays Code 03 message Step Ohms Motor thermal device When cool, correct cause Sprayer Will Not Run Sprayer Will Not RunOhms Sprayer Will Not Shut Off Troubleshooting ProcedureSee 395/490/495 Stand Sprayers132 Ref. Part Description 395/490/495 Stand Sprayers Parts ListQty 395/490/495/595 Lo-Boy Sprayers 117 132 395/490/495/595 Lo-Boy Sprayers Parts List 395/490/495/595 Hi-Boy Sprayers 117 Ref. Part 395/490/495/595 Hi-Boy Sprayers Parts ListAlert  Accessories and LabelsControl Box Grommet Control Box Parts ListControl Box 120V, US/Japan Wiring Diagrams110V, UK 395/490/495/595 Technical SpecificationsNoise** dBa @ 70 psi 0.48 MPa, 4.8 bar For Graco Canada Customers Graco Standard WarrantyInternational Offices Belgium, China, Japan, Korea Graco Information