Graco 395/490/495/595 Electrical, Error Code Messages, Perform Pressure Relief Procedure

Page 32

Troubleshooting

Electrical

Symptom: Sprayer does not run, stops running, or will not shut off.

Perform Pressure Relief Procedure, page 13.

1.Plug sprayer into correct voltage, grounded outlet.

2.Turn the ON/OFF switch OFF wait 30 seconds and then turn power back ON again (this ensures sprayer is in normal run mode).

3.Turn pressure control knob clockwise 1/2 turn.

4.View digital display or remove control box cover to view control board status light. To determine which code (or any other code besides voltage supply) refer to the control board status light. Turn the ON/OFF switch OFF, remove the control cover then turn power back ON. Observe the status light. Blinking LED total count equals the error code (for example: two blinks equals CODE 02).Press display button to restart code messages.

Keep clear of electrical and moving parts during troubleshooting procedures. To avoid electrical shock hazards when covers are removed for troubleshooting, wait 7 seconds after disconnecting power cord for stored electricity to dissipate.

Error Code Messages

CODE

MESSAGE

ACTION

 

 

 

02

HIGH PRESSURE

Check for clogs. Use only Graco spray hoses,

 

DETECTED - RELIEVE

use a minimum of 50ft/15m.

 

PRESSURE

 

 

 

 

03

PRESSURE TRANSDUCER

Check transducer connection.

 

NOT DETECTED

 

 

 

 

05

MOTOR NOT SPINNING

Check for mechanical failure and check motor

 

 

connections. Material may be too thick, thin

 

 

material.

 

 

 

06

MOTOR OVERHEATED

Turn sprayer OFF. Check motor connections.

 

 

Check shroud vents for blockage. Sprayer

 

 

may take up to an hour to cool.

 

 

 

32

334530A

Image 32
Contents Related Manuals Contractor/FTxSG3 334599Contents Models Hi-BoyStand Lo-Boy ModelGrounding Extension CordsFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Component Identification Stand ModelsLo-Boy Models Hi-Boy Models Hi-Boy Models Power Requirements GroundingExtension Cords PailsPressure Relief Procedure Trigger Lock Setup 334530ATi24638a Make certain ON/OFF switch is OFF Setup Perform Pressure Relief Procedure Startup20 s Spray Tip Installation Perform Pressure Relief Procedure,Operation SprayClear Tip Clog Stored Data Display Pressure Display Perform Pressure Relief Procedure,Digital Display Ti2824a Cleanup Fast Flush Drain TubeFast Flush Hose and Gun To flush drain tube and pump turn prime valve downIf flushing with water, flush again with Maintenance Activity IntervalRefer to this column TroubleshootingMechanical/Fluid Flow Properly installed to allow full Possible during priming Electrical Error Code MessagesPerform Pressure Relief Procedure, Problem What to Check How to check System see Pressure ReliefDisplays Code 03 message Step Ohms Motor thermal device When cool, correct cause Sprayer Will Not Run Sprayer Will Not RunOhms Troubleshooting Procedure Sprayer Will Not Shut Off395/490/495 Stand Sprayers See132 Qty 395/490/495 Stand Sprayers Parts ListRef. Part Description 395/490/495/595 Lo-Boy Sprayers 117 132 395/490/495/595 Lo-Boy Sprayers Parts List 395/490/495/595 Hi-Boy Sprayers 117 395/490/495/595 Hi-Boy Sprayers Parts List Ref. PartAccessories and Labels Alert Control Box Control Box Parts List GrommetControl Box Wiring Diagrams 120V, US/Japan110V, UK Technical Specifications 395/490/495/595Noise** dBa @ 70 psi 0.48 MPa, 4.8 bar Graco Standard Warranty For Graco Canada CustomersGraco Information International Offices Belgium, China, Japan, Korea