Graco 395/490/495/595 important safety instructions Sprayer Will Not Run

Page 38

Troubleshooting

Sprayer Will Not Run

(See following page for steps)

Sprayer Will Not Run

(see following pages for steps)

Remove Control box cover. Turn sprayer ON. Observe control board status light on control board (see page 27).

No Light

Once

Normal Operation

Light on

Control board

Commanding motor

continuously

 

to run

 

See Code section for

See Step 1. Do you have over 100 VAC

(220 VAC for 230v units)?

YES

NO

See Step 2. Do you have over 100 VAC

(220 VAC for 230v units)?

Flashing

further troubleshooting

 

 

YES

 

NO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Replace

 

Repair or

the On/Off

 

replace

 

switch.

 

power cord.

See Step 3. Is there

Continuity through the thermal switch wires?

YES

See Step 4.

Does the motor run?

If motor is hot, let cool and retest. If Step 3 still NO shows no continuity, replace motor. The motor

has a defective thermal device.

 

 

 

Connect a test transducer to the board.

NO

 

 

 

 

 

Does the motor run?

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

YES

Replace the potentiometer.

YES

Replace

the transducer

NO

Replace

the control board

ti24726a

38

334530A

Image 38
Contents SG3 Related ManualsContractor/FTx 334599Contents Stand Lo-Boy ModelsHi-Boy ModelGrounding Extension CordsFire and Explosion Hazard Equipment Misuse Hazard Personal Protective Equipment Component Identification Stand ModelsLo-Boy Models Hi-Boy Models Hi-Boy Models Extension Cords Power RequirementsGrounding PailsPressure Relief Procedure Trigger Lock Setup 334530ATi24638a Make certain ON/OFF switch is OFF Setup Perform Pressure Relief Procedure Startup20 s Operation Spray Tip InstallationPerform Pressure Relief Procedure, SprayClear Tip Clog Stored Data Display Pressure Display Perform Pressure Relief Procedure,Digital Display Ti2824a Cleanup Fast Flush Drain TubeFast Flush Hose and Gun To flush drain tube and pump turn prime valve downIf flushing with water, flush again with Maintenance Activity IntervalRefer to this column TroubleshootingMechanical/Fluid Flow Properly installed to allow full Possible during priming Electrical Error Code MessagesPerform Pressure Relief Procedure, Problem What to Check How to check System see Pressure ReliefDisplays Code 03 message Step Ohms Motor thermal device When cool, correct cause Sprayer Will Not Run Sprayer Will Not RunOhms Troubleshooting Procedure Sprayer Will Not Shut Off395/490/495 Stand Sprayers See132 Qty 395/490/495 Stand Sprayers Parts ListRef. Part Description 395/490/495/595 Lo-Boy Sprayers 117 132 395/490/495/595 Lo-Boy Sprayers Parts List 395/490/495/595 Hi-Boy Sprayers 117 395/490/495/595 Hi-Boy Sprayers Parts List Ref. PartAccessories and Labels Alert Control Box Control Box Parts List GrommetControl Box Wiring Diagrams 120V, US/Japan110V, UK Technical Specifications 395/490/495/595Noise** dBa @ 70 psi 0.48 MPa, 4.8 bar Graco Standard Warranty For Graco Canada CustomersGraco Information International Offices Belgium, China, Japan, Korea