Graco Inc 218-745, 307-712, PRO 5000 manual Test Resistor Stud Resistance

Page 17

ELECTRICAL TESTS

Test Resistor Stud Resistance

Insert a conductive rod (FF) into the gun barrel (removed for the power supply test) and against the metal contact (GG) in the front of the barrel. See Fig 9.

Measure the resistance between the conductive rod (FF) and the gun electrode (14). The resistance should be 20 to 30 megohms. If the resistance is correct, refer to the Electrical Troubleshooting Chart for other possible causes of poor performance, or contact the nearest authorized service agency.

If the resistance is outside the specified range, remove the electrode (14). See Electrode Replacement. Meas- ure the resistance between the conductive rod (FF) and the resistor in the inside diameter of resistor stud (17).

KEY

AMegohmmeter FF Conductive Rod

GG

Metal Contact

A

14

Electrode

 

20

Gun Barrel

 

The resistance should be 20 to 30 megohms. If the resis- tance is correct, the electrode wire is defective and must be replaced. See Electrode Replacement. If the resis- tance is outside the specified range, the resistor is defec- tive and the resistor stud (17) must be replaced. See Re- sistor Stud Replacement.

If you still have problems, refer to the Electrical Troubleshooting Chart for other possible causes of poor performance, or contact the nearest authorized service agency.

GG

14

Fig 9

20

FF

 

Image 17
Contents Rev P Automatic MID-RANGE ElectrostaticPart Number 218±745, Series B This manual contains Important  Terms Table of ContentsHazardous Fluid Hazard Hose SafetyEquipment Misuse Hazard Ventilate the Spray Booth Flushing and Cleaning SafetyFire or Explosion Hazard HOW the Electrostatic AIR Spray GUN WorksVentilate the Spray Booth Typical InstallationNON±HAZARDOUS Area KEY Hazardous AreaMount the Gun InstallationCheck the Electrical Grounding Installing Optional Remote Fan Air AdapterOperation Operating ChecklistFilter the Fluid Spraying OperationAccessories Adjust the Spray PatternDaily Care and Cleaning MaintenanceFlush the Spray Gun GUN in SolventEquipment needed To Clean or Change Air Cap and Fluid NozzleProblem Cause Solution Improper Spray Pattern Spray Pattern Troubleshooting ChartProblem Cause Solution GUN Operation Troubleshooting ChartSee Check the Electrical Grounding Electrical Troubleshooting ChartTest Gun Resistance Test Power Supply ResistanceElectrical Tests Test Resistor Stud Resistance Gun Disassembly ServiceGun Assembly Note Electrode ReplacementTo install the resistor stud Resistor Stud Replacement66b Fluid Needle Packing ReplacementBarrel Removal Service Power Cartridge Replacement Turbine Alternator RemovalFan Air Valve Replacement Piston Removal and Repair Disc Regulator ORing Replacement Detail a Ref No Power CartridgeRef No 66, Tool Kit Old/New Style Resistor Stud and Electrode Parts ListDescription Qty KitsService Information Technical DataHOW to Order Replacement Parts Assembly Changed Status No. Part No NameHigh Volume AIR Regulator 206±199 AccessoriesGrounded AIR Supply Hose AIR Hose Adapter 185±493Filter AIR or Paint 202±271 Remote Switch & Signal Light 728±386 Control Panel 218±394Electrostatic System 231±035 Electrostatic System 231±036Warranty Graco Warranty and DisclaimersImportant Phone Numbers To you 1±800±328±0211 Toll Free