Carrier 50XJ064-104 specifications PCB2 J1, 50BVJ,K,W,X Field-Installed Low Voltage Schematic

Page 34

34

PCB2 J1

SW1

1 2 3 4 5 6 7 8

1

 

0

SW2

 

1 2 3 4 5 6 7 8

INT

 

EXT

SW3

J4

 

1 2 3 4 5 6 7 8

20MA

 

OTHER

SW4

 

1 2 3 4 5 6 7 8 10VDC

OTHER

SW5

 

 

 

1

2

3

4

DO

 

 

 

 

AO

SW6

 

 

 

1

2

3

4

DO

 

 

 

 

AO

J3

J7

3 2 1

TO PCB1 (J7)

1

TRANS-2 (24VAC)

11

TRANS-1 R

TRANS-1 C

10

 

CBR

 

 

 

 

 

20

BLU

YEL

 

20

 

 

 

2

 

 

PHASE

 

PHASER

 

 

21

 

TB1-1

TB1-3

 

WIRE LEGEND

 

A B

10

3

 

21

C NO

236

 

 

 

 

TB1-2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT WIRING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIELD WIRING

16

 

CDWFS

237 A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

235

 

CDWF

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

5

3

 

 

 

BLU

 

 

 

 

14

 

Factory Jumper *

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DIS-7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MSR1

5

 

 

 

DIS-8

 

 

 

 

233

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

B

 

 

 

 

233

 

234

+

 

-

 

 

 

 

 

 

235

 

 

 

 

MSR2

 

 

 

BPS_S

 

 

 

 

12

 

+

-

 

 

 

 

 

 

A

 

B

 

 

 

 

 

A

TRMOP

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

232

 

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

232

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

+

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HIR

 

 

 

 

 

 

 

ECONO MBV

 

 

 

 

10

 

11

 

 

 

 

 

 

 

 

 

 

 

 

AQUA

 

RAT

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANS-3 R

 

 

 

1

 

24VAC

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

228

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

MBVR

 

 

 

 

1

 

2

 

Close

 

 

 

COMMON TB

 

 

 

A

B

TRANS-3 C

MBVR

 

3

 

 

 

 

7

 

 

 

 

7

4

 

 

Open

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

ECONO Modulating

 

 

 

231

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

5

 

 

 

 

TRANS-1 C

 

 

 

COMMON

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

TRANS-1 R

 

 

 

2

 

24VAC

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

230

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

4

 

0-20 MA

 

 

 

 

2

 

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

- TRMCT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

229

 

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

+

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIELD CONN

 

 

 

VENTR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TB2

17

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

207

 

RESET

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

210

 

SPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

C

212

3

5

 

 

 

 

 

 

 

 

 

 

 

 

 

228

 

HWV

14

 

BYPAS

 

 

 

 

 

 

 

 

 

 

 

 

5

3

227

211

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

13

 

BYPASS OPTION

 

 

 

 

 

 

 

 

 

 

TRMOP

 

 

226

TRMOP

12

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

3

225

 

210

 

 

 

 

 

 

 

 

 

 

 

 

 

VENTR

 

 

 

VENTR

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

224

209

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

3

 

 

10

 

 

 

11

A

 

B

 

 

 

 

 

 

 

223

 

 

 

 

 

219

 

 

 

 

 

 

 

 

 

208

 

 

 

 

 

 

 

 

 

 

 

 

TRMCT

 

 

222

TRMCT

9

 

FREEZ

 

 

ROCC

 

 

 

 

 

 

3

8

 

 

 

 

 

 

 

 

 

 

5

221

 

 

ECONO OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A

 

B

216

 

 

 

 

 

HIR

 

 

 

 

207

 

 

 

 

 

 

 

 

 

 

 

 

220

HIR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

3

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

206

 

 

FSD

 

 

 

 

 

 

 

 

 

 

102

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

PHASER

 

 

B

RED LOCAL MODE

 

 

 

To PCB1

101

SAT

205

 

 

 

A

 

 

 

 

 

 

 

 

 

 

 

 

DIS-5

 

 

 

 

 

 

 

 

 

 

5

 

 

BRN

 

 

 

218

 

 

SW

 

 

 

 

 

 

219

 

204

 

 

 

MSR2

 

OFF

 

 

 

 

 

 

 

 

ROCC

 

 

 

 

 

BLU

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

203

 

FLTS

 

 

A

 

 

DIS-6

 

DIS-111

 

 

 

10

 

 

 

C

3

 

 

11

 

B 217

YEL

 

To 111

DIS-C

 

 

 

 

216

FSD

202

 

 

 

 

 

 

 

REMOTE

 

 

 

 

 

 

 

 

2

 

 

 

 

MSR1

 

 

 

 

 

 

 

 

215

 

 

MA_RA

 

 

 

 

 

 

 

 

 

 

 

 

ALM-CM

201

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

ALARM

5

3

214

ALARM

NOTES:

 

 

 

 

 

 

 

 

 

 

 

5

3

213

 

 

 

 

 

 

 

 

 

 

 

WARN

WARN

* JUMPER INSTALLED FOR THIS DEVICE WHEN NOT SUPPLIED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEE W/D NUMBER CNTL0038A FOR PCB1 LOW VOLTAGE WIRING.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEE W/D NUMBER CNTL0038C FOR HIGH VOLTAGE WIRING.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SEE W/D NUMBER CNTL0038D FOR LEGEND.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

50BVJ,K,W,X Field-Installed Low Voltage Schematic

Image 34
Contents Controls Operation Troubleshooting Page Control Inputs and Outputs SW2 SW3 SW1Communication Cable Recommendations Manufacturer Part NumberWhen the unit is off, both valves are closed Field Terminal Blocks for 50XJ Unit Space Temperature Sensor Typical Wiring 33ZCT55SPT Numeric Keys LID Function KeysOperative Keys Operative USE KeysOmnizone Vpac Quick Access Chart KEY Algo Stat Hist Srvc Alrm SETOmnizone Page SETPT01 Controller Set Points OMNIZONESETPT02Controller Hardware Points Configuration ParametersSoftware Points Operation Page Page RUN Keys and Functions for 50XJ VFD VFD Non-Trip Messages for 50XJ UnitVFD Trip Messages for 50XJ Unit KEY Operaton LED Message Explanation VFD Mode Summary for 50XJ UnitDown 50BV VFD Display Non-Trip Messages for the 50BV VFD Trip Messages for 50BV VFDEpho OL1OL2 EPH1Error Communication Problem Possible Causes Remedies Code Forcing an Input or Output Run Test TroubleshootingClearing a Forced Input or Output Alarms Displayed at Unit LID Compressor MUX Board Voltages Comp Volts Range50BVJ,K Low Voltage Schematic Unit Wiring50BVJ,K High Voltage Schematic 50BVW,X Low Voltage Schematic TRANS-3 24VAC BLU50BVW,X High Voltage Schematic 50BVJ,K,W,X Field-Installed Low Voltage Schematic PCB2 J150BVJ,K Field-Installed Low Voltage Schemtic 3 4 5 6 750BVW,X Field-installed Low Voltage Schematic Field WiringSPT RoccAqua Bpss50XJ Low Voltage Control Wiring LOW Voltage Control Wiring50XJ 115V Control Wiring BLK VIO Switch Settings50XJ Power Wiring Power Wiring50BV,XJ Accessory Control Module PCB3 Schematic PCB3HRN HeatCdwfs IFMDescription Value Units Status Force Name Cdwf 0=NO,1=YES Cdfwswt Econ 0=NO,1=YES Ewtsns NumcmpRsetrto EwtrstDescription Value Units Name SENSDI00 PntnameSETPT09 SETPT00High Conversion Endpoint 309.77 Comparison Point OMNIZONEDSALM02 Phase Protection Monitored Input Point OMNIZONEDSALM05 Fire alarm Monitored Input Point OMNIZONEDSALM08 Compressor 1 Alarm Monitored Input Point DISCRO00 LINK09 OMNIZONEINTLK02 Ok to Cool Discrete Output Point NTFC00 VOLTI00SETPT03 HCVAV01OMNIZONELMALM02 Entering WaterTemp Monitored Input Point DOW3 DOW1DOW2 DOW4Maintenance Screens ADAPT03 FalseCcvvrf LMALM03Eeprom ADAPT02ADAPT01 RAMDodxrf Description Value Units Status Force Name ANCTL01 CCVAV01Tasktimr LMALM02Resched Taskstat Exetime

50XJ064-104 specifications

The Carrier 50XJ064-104 is a high-efficiency rooftop air conditioning system designed to deliver exceptional cooling and heating capabilities for diverse commercial applications. One of the standout features of this model is its robust cooling capacity of 64,000 BTUs, making it suitable for mid to large-sized spaces. The 50XJ064-104 is engineered using advanced technologies to ensure energy efficiency and reliable performance, contributing to reduced operational costs and environmental sustainability.

One of the primary technologies employed in the Carrier 50XJ064-104 is the high-efficiency scroll compressor. This component plays a pivotal role in optimizing energy usage while delivering consistent cooling output. The system also incorporates an economizer that allows for enhanced energy savings by utilizing outdoor air for cooling when conditions are favorable. This not only decreases reliance on the compressor but also improves indoor air quality.

The microprocessor-based controls in the 50XJ064-104 provide precise temperature regulation, ensuring optimal comfort levels in various applications. These controls allow for easy programming and can be integrated into building management systems for centralized oversight. Additionally, the unit features a built-in fault detection and diagnostic system that aids in identifying potential issues before they escalate, minimizing downtime and maintenance costs.

The Carrier 50XJ064-104 is designed with durability in mind. It features a weather-resistant cabinet, designed to withstand harsh outdoor conditions and prolong service life. The high-quality insulation within the unit not only enhances energy efficiency but also minimizes noise levels, making it an ideal choice for urban environments where sound control is critical.

Another important characteristic is its environmentally friendly R-410A refrigerant, which has a lower impact on ozone depletion compared to older refrigerants. This aligns with Carrier's commitment to creating sustainable HVAC solutions that comply with current environmental regulations.

Overall, the Carrier 50XJ064-104 stands out for its combination of efficiency, advanced technologies, and durable construction. Whether for commercial buildings, retail spaces, or industrial applications, this rooftop air conditioning unit is designed to provide reliable performance and comfort year-round.