Carrier 50XJ064-104 specifications ADAPT02, ADAPT01, Eeprom, Ram, True

Page 60

Maintenance Screens (cont)

DESCRIPTION

VALUE

UNITS

STATUS

FORCE

NAME

OMNIZONE::PRES: Head Pressure(Comp1)

 

 

 

 

 

System Value

118.76

PSIG

 

 

Sysvalue

Force

0

 

 

 

Force

Status

0

 

 

 

HwStat

Alarm Status

Normal

 

 

 

AlmStat

Sensor Value

118.76

PSIG

 

 

SenValue

Hardware Value

1.9

Volts

 

 

HwValue

Channel Number

24

 

 

 

ChanNum

Control Algorithm Name

ADAPT02

 

 

 

AlgoName

Alarm Algorithm Name

 

 

 

 

AlmName

OMNIZONE::RESET: Ext. Supply Air Reset

 

 

 

 

 

System Value

0

dF

 

 

Sysvalue

Force

0

 

 

 

Force

Status

0

 

 

 

HwStat

Alarm Status

Normal

 

 

 

AlmStat

Sensor Value

0

dF

 

 

SenValue

Hardware Value

1.1

Volts

 

 

HwValue

Channel Number

20

 

 

 

ChanNum

Control Algorithm Name

ADAPT01

 

 

 

AlgoName

Alarm Algorithm Name

 

 

 

 

AlmName

OMNIZONE::UPDATEDB: Database Control

 

 

 

 

 

Database Error

No

 

 

 

DBError

EEPROM Error

No

 

 

 

EEError

RAM Error

No

 

 

 

RAMError

Available Program Bytes

11130

 

 

 

EEPROM

Available Data Bytes

14742

 

 

 

RAM

OMNIZONE::ALARM: Critical Fault (Typical Discrete Out)

 

 

 

 

 

System Value

Off

 

 

 

SysVal

Force

0

 

 

 

Force

Status

0

 

 

 

HwStat

Alarm Status

Normal

 

 

 

AlmStat

Control Value

Off

 

 

 

CtrValue

Hardware Value

Open

 

 

 

HdwValue

Channel Number

16

 

 

 

ChanNum

Control Algorithm Name

 

 

 

 

AlgoName

Alarm Algorithm Name

 

 

 

 

AlmName

OMNIZONE::BP_SAFE: Bypass Acc Panel Secure (Typical Discrete Software)

 

 

 

 

 

System Value

No

 

 

 

Sysvalue

Force

0

 

 

 

Force

Status

0

 

 

 

Status

Alarm Status

Normal

 

 

 

AlmStat

OMNIZONE::DOPI_01: Supply Fan Status

 

 

 

 

 

Discrete Output Point

Off

 

 

Control

Value

Occupied ?

No

 

 

 

Status

Permissive Interlock

 

 

 

 

 

Reference Output

0

 

 

 

RefOut

Perm Interlock Flag

TRUE

 

 

 

PIFlag

Conditional

Low

 

 

 

Condtion

Modified Setpoint

0.5

in H2O

 

 

ModStpt

Persistence Timer

0

sec

 

 

PersTime

Setpoint Limit

0.3

in H2O

 

 

Value

Analog Control Point

0.17

in H2O

 

 

Value

Discrete Control Point

Off

 

 

 

Value

Task Timer

1

sec

 

 

TaskTimr

OMNIZONE::DSALM01: Duct High Pressure (Typical Discrete Alarm)

 

 

 

 

 

Monitored Input Point

Off

 

 

 

Value

Comparison Point

Off

 

 

 

Value

Alarm Inhibit Point

Off

 

 

 

Value

Alarm Status

Normal

 

 

 

Status

Alarm Processor

 

 

 

 

 

Alarm Type

0

 

 

 

AlmType

Time of Last Message

0:00

 

 

 

LastTime

Month of Last Message

0

 

 

 

LastDate

Day of Last Message

0

 

 

 

LastDate

Year of Last Message

0

 

 

 

LastDate

Task Timer

2

sec

 

 

TaskTimr

60

Image 60
Contents Controls Operation Troubleshooting Page Control Inputs and Outputs SW2 SW3 SW1Communication Cable Recommendations Manufacturer Part NumberWhen the unit is off, both valves are closed Field Terminal Blocks for 50XJ Unit Space Temperature Sensor Typical Wiring 33ZCT55SPT LID Function Keys Operative KeysNumeric Keys Operative USE KeysOmnizone Vpac Quick Access Chart KEY Algo Stat Hist Srvc Alrm SETOmnizone Page SETPT01 Controller Set Points OMNIZONESETPT02Configuration Parameters Controller Hardware PointsSoftware Points Operation Page Page RUN Keys and Functions for 50XJ VFD VFD Non-Trip Messages for 50XJ UnitVFD Trip Messages for 50XJ Unit VFD Mode Summary for 50XJ Unit KEY Operaton LED Message ExplanationDown 50BV VFD Display Non-Trip Messages for the 50BV VFD Trip Messages for 50BV VFDOL1 OL2Epho EPH1Error Communication Problem Possible Causes Remedies Code Run Test Troubleshooting Forcing an Input or OutputClearing a Forced Input or Output Alarms Displayed at Unit LID Compressor MUX Board Voltages Comp Volts Range50BVJ,K Low Voltage Schematic Unit Wiring50BVJ,K High Voltage Schematic 50BVW,X Low Voltage Schematic TRANS-3 24VAC BLU50BVW,X High Voltage Schematic 50BVJ,K,W,X Field-Installed Low Voltage Schematic PCB2 J150BVJ,K Field-Installed Low Voltage Schemtic 3 4 5 6 750BVW,X Field-installed Low Voltage Schematic Field WiringRocc AquaSPT Bpss50XJ Low Voltage Control Wiring LOW Voltage Control Wiring50XJ 115V Control Wiring BLK VIO Switch Settings50XJ Power Wiring Power Wiring50BV,XJ Accessory Control Module PCB3 Schematic PCB3Heat CdwfsHRN IFMDescription Value Units Status Force Name Numcmp RsetrtoCdwf 0=NO,1=YES Cdfwswt Econ 0=NO,1=YES Ewtsns EwtrstDescription Value Units Name Pntname SETPT09SENSDI00 SETPT00High Conversion Endpoint 309.77 Comparison Point OMNIZONEDSALM02 Phase Protection Monitored Input Point OMNIZONEDSALM05 Fire alarm Monitored Input Point OMNIZONEDSALM08 Compressor 1 Alarm Monitored Input Point DISCRO00 LINK09 OMNIZONEINTLK02 Ok to Cool Discrete Output Point VOLTI00 SETPT03NTFC00 HCVAV01OMNIZONELMALM02 Entering WaterTemp Monitored Input Point DOW1 DOW2DOW3 DOW4Maintenance Screens False CcvvrfADAPT03 LMALM03ADAPT02 ADAPT01Eeprom RAMDodxrf Description Value Units Status Force Name ANCTL01 CCVAV01LMALM02 Resched TaskstatTasktimr Exetime

50XJ064-104 specifications

The Carrier 50XJ064-104 is a high-efficiency rooftop air conditioning system designed to deliver exceptional cooling and heating capabilities for diverse commercial applications. One of the standout features of this model is its robust cooling capacity of 64,000 BTUs, making it suitable for mid to large-sized spaces. The 50XJ064-104 is engineered using advanced technologies to ensure energy efficiency and reliable performance, contributing to reduced operational costs and environmental sustainability.

One of the primary technologies employed in the Carrier 50XJ064-104 is the high-efficiency scroll compressor. This component plays a pivotal role in optimizing energy usage while delivering consistent cooling output. The system also incorporates an economizer that allows for enhanced energy savings by utilizing outdoor air for cooling when conditions are favorable. This not only decreases reliance on the compressor but also improves indoor air quality.

The microprocessor-based controls in the 50XJ064-104 provide precise temperature regulation, ensuring optimal comfort levels in various applications. These controls allow for easy programming and can be integrated into building management systems for centralized oversight. Additionally, the unit features a built-in fault detection and diagnostic system that aids in identifying potential issues before they escalate, minimizing downtime and maintenance costs.

The Carrier 50XJ064-104 is designed with durability in mind. It features a weather-resistant cabinet, designed to withstand harsh outdoor conditions and prolong service life. The high-quality insulation within the unit not only enhances energy efficiency but also minimizes noise levels, making it an ideal choice for urban environments where sound control is critical.

Another important characteristic is its environmentally friendly R-410A refrigerant, which has a lower impact on ozone depletion compared to older refrigerants. This aligns with Carrier's commitment to creating sustainable HVAC solutions that comply with current environmental regulations.

Overall, the Carrier 50XJ064-104 stands out for its combination of efficiency, advanced technologies, and durable construction. Whether for commercial buildings, retail spaces, or industrial applications, this rooftop air conditioning unit is designed to provide reliable performance and comfort year-round.