Carrier 50XJ064-104 Heat, Cdwfs, Hrn, Ifm, Comp, Cuvl, Mvlv, DISC1, Speed, TB1, TB3, Towe, Trmct

Page 42

LEGEND AND NOTES FOR ALL 50XJ WIRING DIAGRAMS

 

 

 

LEGEND

ALARM — Unit Alarm Relay (Critical Fault)

FREEZ — Freeze Thermostat

ALM-CMAlarm/Warning Relay Common

 

(Water Economizer)

BPS_S

Fan Start/Stop Relay

FRZ

Freeze Thermostat (DX Circuit)

 

(VFD Bypass Mode)

FSD

Fire Alarm/Shutdown

BYPAS

VFD Bypass Control

FU

Fuse

C

Compressor Contactor

GND

Ground

CB

Circuit Breaker

HEAT

Electric Heat Stage Control

CDWF

Condenser Waterflow Relay

HIR

Heat Interlock Relay

CDWFS

Condenser Waterflow Switch

HPS

High Refrigerant Pressure Switch

CH

Crankcase Heater

HRN

Harness

CLO

Compressor Lockout Control

HWV

Hot Water Valve

CMP

Compressor Control Relay

IFM

Indoor Fan Motor

COMP

Compressor

J

Jumper Wire

CSMUX

Signal Multiplexer-Comp Status

LPS

Low Refrigerant Pressure Switch

CUVL

UVC Light For Indoor Coil Area

MA_RA— Mixed/Return Air Temp. Sensor

DEHUM — External Dehumidification

MVLV

Modulating Valve (Econ)/

DHS

Duct High Static Limit Switch

 

Heat Pres. Ctl.

DISC1

Disconnect Switch

OLR

Compressor Motor Protector

DS

Door Switch

PCB1

Unit Control Board

DSP

Duct Static Pressure Transducer

PCB2,3— I/O Expansion Board

ECONO — Economizer Valve/Damper

PHASE— Phase/Rotation Monitor

 

Control

PUMP — Water Pump Request

EWT

Entering Water Temp. Sensor

RESET — External Reset

FLTS

Filter Status Switch

ROCC — Remote Occupancy

SAT

Supply Air Temp. Sensor

SPT

Space/Zone Temperature Sensor

SF

Supply Fan Start/Stop Relay

SPEED

0-10 VDC Signal Isolator for VFD

SW

Switch

TTransformer

TB1

Power Distribution Terminal Block

TB2

120 V-Hot Terminal Block

TB3

120 V-Neutral Terminal Block

TB5-7

Terminal Blocks for

TOWE

Field Connections

Tower Request

R

 

TRMCT

VAV Terminals Control

TRMOP

VAV Terminals Open

VENTR

Ventilation Output

VFD

Variable Frequency Drive

WARN — Unit Warning Relay

(Non-Critical Fault)

Optional Wiring

(Optional Items Noted With “*”)

Field Wiring

NOTES:

1.Partial wiring shown on both power and control diagrams.

2.All class 2 transformers are wired into separate circuits. Do not interconnect these transformers or circuits; circuit separation shall be maintained.

3.On 200/240 v units, the transformers are factory wired for 240 v. For 200 v applica- tions, move the blue wire to the 200 v tap of each transformer.

4.Shielded wire shall have drain wire connected to VFD ground screw. The floating end of the drain wire shall be insulated.

5.Shielded wire shall have drain wire connected to the control panel, adjacent to the PCB. The floating end of the drain wire shall be insulated.

42

Image 42
Contents Controls Operation Troubleshooting Page Control Inputs and Outputs SW2 SW3 SW1Communication Cable Recommendations Manufacturer Part NumberWhen the unit is off, both valves are closed Field Terminal Blocks for 50XJ Unit Space Temperature Sensor Typical Wiring 33ZCT55SPT Numeric Keys LID Function KeysOperative Keys Operative USE KeysOmnizone Vpac Quick Access Chart KEY Algo Stat Hist Srvc Alrm SETOmnizone Page SETPT01 Controller Set Points OMNIZONESETPT02Configuration Parameters Controller Hardware PointsSoftware Points Operation Page Page RUN Keys and Functions for 50XJ VFD VFD Non-Trip Messages for 50XJ UnitVFD Trip Messages for 50XJ Unit VFD Mode Summary for 50XJ Unit KEY Operaton LED Message ExplanationDown 50BV VFD Display Non-Trip Messages for the 50BV VFD Trip Messages for 50BV VFDEpho OL1OL2 EPH1Error Communication Problem Possible Causes Remedies Code Run Test Troubleshooting Forcing an Input or OutputClearing a Forced Input or Output Alarms Displayed at Unit LID Compressor MUX Board Voltages Comp Volts Range50BVJ,K Low Voltage Schematic Unit Wiring50BVJ,K High Voltage Schematic 50BVW,X Low Voltage Schematic TRANS-3 24VAC BLU50BVW,X High Voltage Schematic 50BVJ,K,W,X Field-Installed Low Voltage Schematic PCB2 J150BVJ,K Field-Installed Low Voltage Schemtic 3 4 5 6 750BVW,X Field-installed Low Voltage Schematic Field WiringSPT RoccAqua Bpss50XJ Low Voltage Control Wiring LOW Voltage Control Wiring50XJ 115V Control Wiring BLK VIO Switch Settings50XJ Power Wiring Power Wiring50BV,XJ Accessory Control Module PCB3 Schematic PCB3HRN HeatCdwfs IFMDescription Value Units Status Force Name Cdwf 0=NO,1=YES Cdfwswt Econ 0=NO,1=YES Ewtsns NumcmpRsetrto EwtrstDescription Value Units Name SENSDI00 PntnameSETPT09 SETPT00High Conversion Endpoint 309.77 Comparison Point OMNIZONEDSALM02 Phase Protection Monitored Input Point OMNIZONEDSALM05 Fire alarm Monitored Input Point OMNIZONEDSALM08 Compressor 1 Alarm Monitored Input Point DISCRO00 LINK09 OMNIZONEINTLK02 Ok to Cool Discrete Output Point NTFC00 VOLTI00SETPT03 HCVAV01OMNIZONELMALM02 Entering WaterTemp Monitored Input Point DOW3 DOW1DOW2 DOW4Maintenance Screens ADAPT03 FalseCcvvrf LMALM03Eeprom ADAPT02ADAPT01 RAMDodxrf Description Value Units Status Force Name ANCTL01 CCVAV01Tasktimr LMALM02Resched Taskstat Exetime

50XJ064-104 specifications

The Carrier 50XJ064-104 is a high-efficiency rooftop air conditioning system designed to deliver exceptional cooling and heating capabilities for diverse commercial applications. One of the standout features of this model is its robust cooling capacity of 64,000 BTUs, making it suitable for mid to large-sized spaces. The 50XJ064-104 is engineered using advanced technologies to ensure energy efficiency and reliable performance, contributing to reduced operational costs and environmental sustainability.

One of the primary technologies employed in the Carrier 50XJ064-104 is the high-efficiency scroll compressor. This component plays a pivotal role in optimizing energy usage while delivering consistent cooling output. The system also incorporates an economizer that allows for enhanced energy savings by utilizing outdoor air for cooling when conditions are favorable. This not only decreases reliance on the compressor but also improves indoor air quality.

The microprocessor-based controls in the 50XJ064-104 provide precise temperature regulation, ensuring optimal comfort levels in various applications. These controls allow for easy programming and can be integrated into building management systems for centralized oversight. Additionally, the unit features a built-in fault detection and diagnostic system that aids in identifying potential issues before they escalate, minimizing downtime and maintenance costs.

The Carrier 50XJ064-104 is designed with durability in mind. It features a weather-resistant cabinet, designed to withstand harsh outdoor conditions and prolong service life. The high-quality insulation within the unit not only enhances energy efficiency but also minimizes noise levels, making it an ideal choice for urban environments where sound control is critical.

Another important characteristic is its environmentally friendly R-410A refrigerant, which has a lower impact on ozone depletion compared to older refrigerants. This aligns with Carrier's commitment to creating sustainable HVAC solutions that comply with current environmental regulations.

Overall, the Carrier 50XJ064-104 stands out for its combination of efficiency, advanced technologies, and durable construction. Whether for commercial buildings, retail spaces, or industrial applications, this rooftop air conditioning unit is designed to provide reliable performance and comfort year-round.