Introduction

 

Operational Tests – Before drilling and during operation it is necessary to check the following: proper calibration, correct ultrasonic measurement, status of battery power, transmitter temperature, and signal interference problems. (see Operational Tests Section)

Locating – The DigiTrak System is used to locate the transmitter underground; the trigger under the receiver’s handle is held in during locating to show signal strength in the upper left window. The operator systematically follows the signals received from the transmitter to establish the FNLP and the rear negative locate point (RNLP), which then guide the operator to the transmitter’s location. (see Locating Section)

Tracking – The DigiTrak Receiver automatically “tracks” and displays the transmitter’s orientation (pitch/ roll) and distance. It is not necessary to push the trigger or take any other steps to see this information.

Troubleshooting – The DigiTrak System is a sensitive instrument whose operation can be affected by many different factors. We have listed many of the common problems and solutions in the Trouble- shooting Section in this manual. If you cannot find the answers you need there, then please call DCI for assistance. (see “Technical Support” below)

Technical Support

If you are having difficulties with your DigiTrak System and cannot find solutions by reviewing this manual or the DigiTrak Training Video, then call DCI’s Customer Service Department at 425-251-0559 or 800-

288-3610. When you call, you should be prepared to provide the following information:

¾Serial numbers on the DigiTrak Receiver, Transmitter, Remote Display, etc.

¾Description of problem.

¾How you have tried to solve the problem.

¾Availability of other equipment to troubleshoot with.

You may also want to visit our web site (www.digitrak.com) for more information, or e-mail us at DCI@digital-control.com.

DigiTrak® Mark III Operator’s Manual

3

Image 11
Contents Mark III Directional Drilling Locating System Trademarks Table of Contents Remote Display System Remote Telemetry License Limited Warranty Safety Precautions Vii Remember Viii Dear CustomerDigiTrak Directional Drilling Locating System IntroductionBasic DigiTrak Equipment Basic DigiTrak Operation IntroductionTechnical Support 3000-00b-F Showing Display Window Icons ReceiverDigiTrak Receiver Side View DigiTrak Receiver Top ViewDisplay Window Icons ReceiverTo turn the receiver on Depth Measurement Units Receiver Battery Voltage LCD TestFirmware Version Remote Channel Setting On/OffTo turn the receiver off Receiving the Transmitter’s SignalsClicking vs. Holding the Trigger To change the channel Changing the Receiver’s Channel SettingTo change the measurement units Battery Status Display for Receiver and TransmitterReceiver Battery Status Voltage Remaining Changing the Depth Measurement Units English vs. MetricUse of Ultrasonic Measurement To Determine Actual Depth Temperature RangeUltrasonic Function Zeroing the Ultrasonics Do not calibrate if Determining 1-Point Calibration SignalCalibrating the Receiver To calibrate newer receivers Confirming Proper CalibrationReceiver Depth Antenna Plumb Line Using Depth Antenna Plumb Line to Mark Locate PointsSeries Firmware Functions Finding Firmware VersionRunning Time Meter Display Procedure for Observing the Predicted DepthDigiTrak Transmitter TransmitterHow a Transmitter Works BatteriesAntenna Index Slot Back FrontTransmitter Temperature DisplayBattery Status Display Temperature OverheatHow Transmitter Should Fit in Housing Sleep Mode Automatic ShutoffVerifying Proper Fit of Transmitter in Housing Front End Cap of Transmitter Showing Temp Dot and Index Slot To install a transmitter in the housingTips for drilling with a sensitive-pitch transmitter Locating the TransmitterSensitive-Pitch Transmitters Transmitter as an InclinometerRange Type Rating SpecificationsModel Type Length Signal Battery Temp Color Transmitter Serial NumbersRemote Display Unit Remote Display SystemRemote Display On/Off and Setting the ChannelTransmitter Temperature and Battery Status Remote Steering Setting up DigiTrak Receiver For Remote SteeringUsing DigiTrak Receiver for Remote Steering ~ I5 DataLog CapabilityDigiTrak Battery Charger Battery ChargerBattery Charger Control Panel Battery ChargerCharging a Battery Battery IsSetup for Discharging a Battery Manually Conditioning a Battery in the ChargerConditioning a Battery Manually Indicator Lights and Meanings3000-00f-F System Operating Instructions Start-up ProcedureShutdown Procedure Moisture and Temperature AvoidanceSystem Operation Optimal Operating TemperaturesGeneral Maintenance Electrical Interference/Background Noise Check Signal InterferenceSuggestions for Dealing with Interference Signal InterferenceReceiver Balance Check Operational TestsSelf-Test for Mark III Receivers Transmitter Tests Operational TestsReceiver Gain Test Transmitter Distance Color Transmitter Signal Strength ValuesTransmitter Model Average Current mA Transmitter Salt Water Range TestCurrent Draw Test Transmitter Battery Tests 3000-00i-F Locate Points Fnlp & Rnlp and Locate Line PLL Locating ModeLocating Mode Trigger Held LocatingSide View LocatingHandling the Receiver Finding the Rear Negative Locate Point Rnlp from the Drill Using Plus/Minus Indicators for LocatingUsing Plus/Minus +/- Indicators for Locating Locating the Transmitter from the DrillFinding the Positive Locate Line PLL from the Drill Fine Tuning Rnlp Location Walking Toward LeftPlus Changes To Minus Drill Finding the Front Negative Locate Point Fnlp from the Drill Fine Tuning Fnlp Walking Toward LeftFinding the Transmitter and Its Depth Method for Confirming Position Locating the Transmitter from the FrontMethod for Confirming Position Locating the Transmitter from the FrontOff-Track Locating Locating on the FlyOff-Track Locating To find the Fnlp or the Rnlp Splitting the Front and Rear Negative Locate PointsFour-Turn Technique Pitch Divider Calculating Depth Based on Distance Between Fnlp & RnlpCalculating Depth from Pitch Running off Pitch or Calculating Depth from PitchElliptical Shape of Transmitter Signal Field Transmitter’s Signal ShapeAntenna Configuration Signal ReceptionOrientation of Field Lines with Respect to Antennas Front and Rear Negative Locate PointsPositive Locate Line Above Transmitter 3000-00j-F DigiTrak Cable Transmitter System Cable Transmitter SystemLabel Indicating Cable-Ready Remote Display Cable TransmitterCable Transmitter Power Supply Connected to Remote Display Power SupplyCable Transmitter Adding Batteries in Series Remote Display with Cable Transmitter CapabilityOperation Viewing the Cable System Battery StatusProblem/Concern Causes/Solutions Section to Consult TroubleshootingTroubleshooting Troubleshooting Troubleshooting Troubleshooting 3000-00l-F Glossary Glossary Set the Ultrasonics Start-up = Power-up = Boot-upRemote Display RollUltrasonic Transducers Ultrasonic FunctionAppendix Percent Depth Increase 100 AppendixPercent of Grade to Degree Conversions Pitch Transmitters Percent Degree Degree to Percent of Grade Conversions Pitch Transmitters Degrees Percent 10.0 Calculating Depth Based on Distance Between Fnlp and Rnlp 3000-00n-F Remote Telemetry License 3000-00o-F Limited Warranty Warranty Claim Procedures