DIGITAL CONTROL INCORPORATED
Troubleshooting
| Problem/Concern | Causes/Solutions | Section to Consult | |
| 1999 in bottom window of | Transmitter is asleep (wake it up by | “Electrical Interference/ | |
| receiver, indicating no signal | rotating the drill string). | Background Noise Check” | |
| is being received from the | Dead batteries in the transmitter. | in Signal Interference | |
| transmitter. | Section | ||
| Broken transmitter. | |||
|
| Transmitter Section | ||
|
| Overheated transmitter. | ||
|
|
|
| |
|
| Transmitter is out of range of receiver. |
|
|
| A number ranging from 200 to | Receiver is receiving background noise. | “Electrical Interference/ | |
| 700 in bottom window of |
| Background Noise Check” | |
| receiver and transmitter is not |
| in Signal Interference | |
| active. |
| Section | |
| Depth suddenly decreases | Ultrasonics have not been zeroed and | “Ultrasonic Function” in | |
| receiver is being set on the ground for | Receiver Section | ||
|
| depth reading. Due to the likelihood of |
|
|
|
| interference, do not measure with the |
|
|
|
| receiver on the ground. |
|
|
| Depth after calibration | Depth measurement mode in receiver has | “Changing the Depth | |
| displays as | been inadvertently changed from inches | Measurement Units” in | |
| of | (English) to centimeters (metric). | Receiver Section | |
| Incorrect depth. | Interference. | “Electrical Interference/ | |
|
| Ultrasonics improperly set. | Background Noise Check” | |
|
| in Signal Interference | ||
|
| Bad calibration. | ||
|
| Section | ||
|
| Weak signal from the transmitter. | ||
|
| “Ultrasonic Function” in | ||
|
| Receiver is not directly over transmitter | Receiver Section | |
|
| when taking a depth reading (trigger must |
|
|
|
| be released). |
|
|
|
| Receiver malfunction. |
|
|
|
|
|
|
|
| Erratic information on | Interference. | “Electrical Interference/ | |
| receiver. | Low battery in receiver. | Background Noise Check” | |
|
| in Signal Interference | ||
|
| Moisture inside the equipment. Call DCI | ||
|
| Section | ||
|
| for information about field methods for | ||
|
| Remote Display Section | ||
|
| “drying” out the equipment. Moisture can | ||
|
| be caused by condensation which occurs |
|
|
|
| when the equipment is repetitively moved |
|
|
|
| to and from a warm environment and a |
|
|
|
| cold one. |
|
|
| Remote display has dashes | Receiver is set on channel 0 (the telemetry | “Changing the Receiver’s | |
| across windows. | is off). | Channel Setting” in | |
|
| Receiver is set to a different channel than | Receiver Section | |
|
|
|
| |
|
| remote display. |
|
|
|
|
|
| |
| DigiTrak® Mark III Operator’s Manual | 63 |
|