489
Communications Guide
Table 5: Binary Inputs (Sheet 3 of 4)
Idx | Description | Class |
|
|
|
|
|
|
82 | Analog Input 3 Trip Active or | Class 1 |
| Latched |
|
|
|
|
83 | Analog Input 4 Trip Active or | Class 1 |
| Latched |
|
|
|
|
84 | Loss of Excitation Circle 1 Trip | Class 1 |
| Active or Latched |
|
|
|
|
85 | Loss of Excitation Circle 2 Trip | Class 1 |
| Active or Latched |
|
|
|
|
86 | Ground Directional Trip Active | Class 1 |
| or Latched |
|
|
|
|
87 | High Set Phase Overcurrent | Class 1 |
| Trip Active or Latched |
|
|
|
|
88 | Distance Zone 1 Trip Active or | Class 1 |
| Latched |
|
|
|
|
89 | Distance Zone 2 Trip Active or | Class 1 |
| Latched |
|
|
|
|
100 | Assignable Input 1 Alarm | Class 1 |
| Active / Latched |
|
|
|
|
101 | Assignable Input 2 Alarm | Class 1 |
| Active or Latched |
|
|
|
|
102 | Assignable Input 3 Alarm | Class 1 |
| Active or Latched |
|
|
|
|
103 | Assignable Input 4 Alarm | Class 1 |
| Active or Latched |
|
|
|
|
104 | Assignable Input 5 Alarm | Class 1 |
| Active or Latched |
|
|
|
|
105 | Assignable Input 6 Alarm | Class 1 |
| Active or Latched |
|
|
|
|
106 | Assignable Input 7 Alarm | Class 1 |
| Active / Latched |
|
|
|
|
107 | Tachometer Alarm Active or | Class 1 |
| Latched |
|
|
|
|
108 | Overcurrent Alarm Active or | Class 1 |
| Latched |
|
|
|
|
109 | Negative Sequence Alarm | Class 1 |
| Active or Latched |
|
|
|
|
110 | Ground Overcurrent Alarm | Class 1 |
| Active or Latched |
|
|
|
|
111 | Undervoltage Alarm Active or | Class 1 |
| Latched |
|
|
|
|
112 | Overvoltage Alarm Active or | Class 1 |
| Latched |
|
|
|
|
113 | Volts/Hertz Alarm Active or | Class 1 |
| Latched |
|
|
|
|
114 | Underfreq Alarm Active or | Class 1 |
| Latched |
|
|
|
|
115 | Overfrequency Alarm Active or | Class 1 |
| Latched |
|
|
|
|
116 | Neutral Overvoltage Alarm | Class 1 |
| Active or Latched |
|
|
|
|
117 | Neutral Undervoltage (Third | Class 1 |
| Harmonic) Alarm Active or |
|
| Latched |
|
|
|
|
118 | Reactive Power Alarm Active or | Class 1 |
| Latched |
|
|
|
|
119 | Reverse Power Alarm Active or | Class 1 |
| Latched |
|
|
|
|
120 | Low Forward Power Alarm | Class 1 |
| Active / Latched |
|
|
|
|
121 | RTD 1 Alarm Active or Latched | Class 1 |
|
|
|
122 | RTD 2 Alarm Active or Latched | Class 1 |
|
|
|
123 | RTD 3 Alarm Active or Latched | Class 1 |
|
|
|
DNP Point Lists
Table 5: Binary Inputs (Sheet 4 of 4)
Idx | Description | Class | |||
|
|
|
|
|
|
|
|
|
|
|
|
124 | RTD 4 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
125 | RTD 5 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
126 | RTD 6 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
127 | RTD 7 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
128 | RTD 8 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
129 | RTD 9 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
130 | RTD 10 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
131 | RTD 11 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
132 | RTD 12 Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
133 | Open Sensor Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
134 | Short/Low Temp Alarm Active | Class 1 | |||
|
|
|
| or Latched |
|
|
|
|
|
|
|
135 | Thermal Model Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
136 | Trip Counter Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
137 | Breaker Failure Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
138 | Trip Coil Monitor Alarm Active | Class 1 | |||
|
|
|
| or Latched |
|
|
|
|
|
|
|
139 | VTFF Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
140 | Current Dmd Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
141 | MW Demand Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
142 | Mvar Demand Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
143 | MVA Alarm Active or Latched | Class 1 | |||
|
|
|
|
|
|
144 | Analog Input 1 Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
145 | Analog Input 2 Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
146 | Analog Input 3 Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
147 | Analog Input 4 Alarm Active or | Class 1 | |||
|
|
|
| Latched |
|
|
|
|
|
|
|
148 | Not Programmed Alarm Active | Class 1 | |||
|
|
|
| or Latched |
|
|
|
|
|
|
|
149 | Simulation Mode Alarm Active | Class 1 | |||
|
|
|
| or Latched |
|
|
|
|
|
|
|
150 | Output Relays Forced Alarm | Class 1 | |||
|
|
|
| Active or Latched |
|
|
|
|
|
|
|
151 | Analog Output Forced Alarm | Class 1 | |||
|
|
|
| Active or Latched |
|
|
|
|
|
|
|
152 | Test Switch Shorted Alarm | Class 1 | |||
|
|
|
| Active or Latched |
|
|
|
|
|
|
|
153 | Ground Directional Alarm | Class 1 | |||
|
|
|
| Active or Latched |
|
|
|
|
|
|
|
154 | Class 1 | ||||
|
|
|
| Latched |
|
|
|
|
|
|
|
155 | Generator Running Hour Alarm | Class 1 | |||
|
|
|
| Active or Latched |
|
|
|
|
|
|
|
|
|
|
| Any detected change in the | |
|
|
|
| ||
|
|
|
| state of any point assigned to | |
|
|
|
| ||
|
|
|
| ||
NOTE | Class 1 will cause the generation | ||||
|
|
|
| of an event object. |
|
50 |
http://www.GEindustrial.com/multilin
GE Multilin |