Delta 36-978 instruction manual Power Connections, Motor Specifications, Grounding Instructions

Page 6

POWER CONNECTIONS

A separate electrical circuit should be used for your machines. This circuit should not be less than #12 wire and should be protected with a 20 Amp time lag fuse. If an extension cord is used, use only 3-wire extension cords which have 3-prong grounding type plugs and matching receptacle which will accept the machine’s plug. Before connecting the machine to the power line, make sure the switch (s) is in the “OFF” position and be sure that the electric current is of the same characteristics as indicated on the machine. All line connections should make good contact. Running on low voltage will damage the machine.

DO NOT EXPOSE THE MACHINE TO RAIN OR OPERATE THE MACHINE IN DAMP LOCATIONS.

MOTOR SPECIFICATIONS

Your machine is wired for 120/240 volts, 60 HZ alternating current. Before connecting the machine to the power source, make sure the switch is in the “OFF” position.

GROUNDING INSTRUCTIONS

THIS MACHINE MUST BE GROUNDED WHILE IN USE TO PROTECT THE OPERATOR FROM ELE CTRIC SHOCK.

1. All grounded, cord-connected machines:

In the event of a malfunction or breakdown, grounding provides a path of least resistance for electric current to reduce the risk of electric shock. This machine is equipped with an electric cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into a matching outlet that is properly installed and grounded in accordance with all local codes and ordinances.

Do not modify the plug provided - if it will not fit the outlet, have the proper outlet installed by a qualified electrician.

Improper connection of the equipment-grounding cond uctor can result in risk of electric shock. The conductor with insulation having an outer surface that is green with or without yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric cord or plug is necessary, do not connect the equipment- grounding conductor to a live terminal.

Check with a qualified electrician or service personnel if the grounding instructions are not completely underst ood, or if in doubt as to whether the machine is properly grounded.

Use only 3-wire extension cords that have 3-prong grounding type plugs and matching 3-conductor receptacles that accept the machine’s plug, as shown in Fig. A. Repair or replace damaged or worn cord immediately.

GROUNDED OUTLET BOX

CURRENT

CARRYING

PRONGS

2.Grounded, cord-connected machines intended for use on a supply circuit having a nominal rating less than 150 volts:

If the machine is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. A, the machine will have a grounding plug that looks like the plug illustrated in Fig. A. A temporary adapter, which looks like the adapter illustrated in Fig. B, may be used to connect this plug to a matching 2-conductor receptacle as shown in Fig. B if a properly grounded outlet is not available. The temporary adapter should be used only until a properly grounded outlet can be installed by a qualified electrician. The green-colored rigid ear, lug, and the like, extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. When ever the adapter is used, it must be held in place with a metal screw.

NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.

IN ALL CASES, MAKE CERTAIN THAT THE RECEPTACLE IN QUESTION IS PROPERLY GROUND ED. IF YOU ARE NOT SURE, HAVE A QUALIFIED ELECTRI CIAN CHECK THE RECEPTACLE.

GROUNDED OUTLET BOX

GROUNDING

MEANS

ADAPTER

GROUNDING BLADE

IS LONGEST OF THE 3 BLADES

Fig. A

6

Fig. B

 

 

Image 6
Contents Contractor’s Saw Model 36-979 Shown With Model 36-B30 Fence SystemTable of Contents Important Safety InstructionsSafety Guidelines Tool Warning LabelsGeneral Safety Rules Important Safety InstructionsAdditional Specific Safety Rules Some Materials are TOO HardPower Connections Motor SpecificationsGrounding Instructions Volt Single Phase Operation Extension CordsCarton Contents Functional DescriptionSheet Metal Extension Wings Extension WingsStand and Mobile Base Parts Cast Iron Extension WingsAssembly Tools Required AssemblyUnpacking and Cleaning Assembly Time EstimateShort and Long LEG Supports Mobile Base and Stand AssemblyFront and Side Panels Corner BracketsAS Shown in FIG Leveling Feet Attaching Foot Lever Assembly to BaseOpen END is Aligned AS Shown in Figs WheelsMobile Base and Stand Assembly to SAW Dust Chute and Back BraceMotor to Motor Mounting Plate Blade Tilting Raising HandwheelWrench Hook E FMotor and Motor Mounting Plate to SAW Motor PULLEY, Pulley GUARD, and Drive BeltTo the Arbor Pulley Connecting Motor Cord to Switch Assembly Removing Motor for TransportBlade Guard and Splitter Assembly and Alignment Assemble the blade guard and splitter assembly Model 36-978 only Model 36-979 onlyOperation ON/OFF SwitchLocking Switch in the OFF Position Starting and Stopping SAWRaising and Lowering Blade Disconnect Machine from Power SourceOverload Protection Tilting the BladeAssembling Miter Gauge Miter Gauge Operation and AdjustmentAdjusting Table Insert Table Insert a should Always be Level with the TableAligning Miter Slots to Blade Changing the SAW BladeQuick Operations Checklist Machine USEKEY Parts and Safety Features on Your SAW Back ViewBlade Guard and Splitter USE CROSS-CUTTINGBevel Crosscutting Never USE the Fence AS a CUT-OFF Gauge When CROSS-CUTTINGMitering Compound MiteringRipping Constructing a Push StickUsing Moulding Cutterhead Bevel RippingUsing Accessory Dado Head Fig. S15Using Auxiliary Wood Facing Fig. S18Troubleshooting Power Tool InstituteConstructing a Featherboard Push Stick Constructing a Push StickMaintenance Shelf MeasurementsService AccessoriesWarranty Delta Machinery