Waring 7155-21 manual Operation, Removing Fastener Strips Clearing a Jammed Fastener

Page 6

Removing Fastener Strips

Clearing a Jammed Fastener

OPERATION

WARNING

To avoid serious injury, disconnect the tool from the air supply before removing fastener strips or clearing a jammed fastener.

Keep fingers clear of fastener track of magazine. Pusher could pinch fingers, causing injury.

1.Lay the tool on its side and point the nose of the tool away from yourself and others.

2.Disconnect the air supply from the tool.

3.Place your hand on the end cap of the pusher assembly before pressing the pusher release button. Press the pusher release button and gently slide back the pusher assembly. Do not allow the pusher assembly to slide back fast.

4.Tip down the nose of the tool to remove fastener strip from the tool.

5.Reload according to "Installing Fastener Strips".

Most jams are caused by a fastener or part of a fastener wedging between the driver blade and the fastener guide. Fastener strips with an incorrect collation angle or the wrong fas- tener type may cause continuous jamming. To clear the jam:

1.Lay the tool on its side and point the nose of the tool away from yourself and others.

2.Disconnect the air supply from the tool and remove fastener strip. Leave the pusher assembly open.

3.Remove any debris.

4.Insert a screwdriver into the end of the fastener guide. The tip of the screw- driver should contact the tip of the driver blade.

5.Tap the screwdriver gently with a ham- mer. The screwdriver will push the driver blade back, freeing the jam.

6.Remove the fastener and other debris (use needle-nose pliers if necessary).

7.Follow the steps under "Required Daily Testing" before restarting the work.

Fig. 4

Tap screwdriver

to free fastener

WARNING

The operator and other people in the work area must wear eye protection in accordance with ANSI Z87.1. Eye protection does not fit all operators in the same way. Make sure the eye protection chosen has side shields or provides protection from flying debris both from the front and sides. The employer is responsible for enforcing the use of eye protection by the opera- tor and other people in the work area. When required, wear head protection in accordance with ANSI Z89.1.

Selecting Actuation Mode

The selectable trigger can be set to either Single Sequential Actuation mode or Contact Actuation mode.

Fig. 5

Single

Sequential

Actuation

WARNING

To reduce the risk of injury to your- self and others, test the tool before beginning work each day according to the "Required Daily Testing" section.

Do not use the tool unless you thor- oughly understand the actuation operation selected.

Disconnect the air supply from the tool and remove fastener strips before leaving the work area, mov- ing the tool to another location, or handing the tool to another person. Failure to do so could result in seri- ous injury.

Do not carry an air hose or a tool con- nected to an air hose when climbing ladders, rigging or scaffolding. Do not attach an air hose or tool con- nected to an air hose to your body when working at elevated heights. Attach the hose to the structure to reduce the risk of loss of balance and injury if the hose shifts.

Single Sequential Actuation Operation

Fig. 6

Contact

Actuation

1.Push in and hold the Actuation Selector.

2.Rotate the Selector to Single Sequen- tial Actuation (T) or Contact Actuation (TTT).

3.Release the Actuation Selector.

NOTE: Be sure the selector is snapped into position. Understand the actuation process before use.

1.Grip the handle firmly.

2.Position the nose of the tool on the work surface.

3.Push the tool against the work surface, compressing the workpiece contact.

4.Pull the trigger to drive the fastener. The tool will recoil away from the workpiece as the fastener is driven.

5.Remove your finger from the trigger and remove the tool from the workpiece.

NOTE: If the tool is not removed from the workpiece, another fastener may be driven if the trigger is pulled again.

10

11

Image 6
Contents 7155-21 General Personal SafetyService Work Area Specific Safety Instructions AIR Source TerminologyFront of tool End cap Belt hook Screw Air inlet Functional Description AssemblyRemoving and Installing the Belt Hook No-Mar PadConnecting the Air Supply Removing Fastener Strips Clearing a Jammed Fastener Selecting Actuation ModeOperation Single Sequential ActuationAlways point tool away from yourself and others Required Daily TestingContact Actuation Operation Received a sharp blow, been run over, jammed, etcCleaning Maintenance Five Year Tool AccessoriesLimited Warranty Air Supply-Pressure and VolumeAire DE Travail Utilisation Correcte DE L’OUTILGénéralités Sécurité IndividuellePrise D’AIR Instructions D’ENTRETIEN Spécifiques EntretienTerminologie Description Fonctionnelle Montage Installation des bandes d’attaches Retrait des bandes d’attachesDéblocage d’une attache Fonctionnement Mode d’actionnement en séquenceMode de fonctionnement par contact Indicateur de rechargeTests Quotidiens Requis Nettoyage Prise d’air Pression et volumeFonctionnement par temps froid Utiliser les attaches Milwaukee aux spécifications suivantesSeguridad Personal Aspectos GeneralesÁrea DE Trabajo USO Y Cuidado DE LA HerramientaReparación Fuente DE AireInstrucciones Específicas DE Seguridad Terminología Descripción Funcional Cómo quitar y colocar el gancho de correa ArmadoCómo conectar el suministro de aire Almohadilla de protecciónCómo desatascar un sujetador atorado Cómo instalar las tiras de sujetadoresCómo quitar las tiras de sujetadores Liberar el sujetadorAccionamiento secuencial único Accionamiento por contacto FuncionamientoCómo seleccionar el modo de acciona- miento Funcionamiento de accionamiento por contactoCómo establecer la presión de aire y el alcance de disparo Evaluación Diaria Necesaria¡ADVERTENCIA Siempre apunte la herramienta lejos de usted y de otrosMantenimiento Garantía Limitada DE Accesorios Advertencia Cinco Años800.729.3878 fax Milwaukee800.729.3878 West Lisbon Road Brookfield, Wisconsin, U.S.A