Grizzly G0609 owner manual Circuit Requirements, 220V Single-Phase

Page 12

SECTION 2: CIRCUIT REQUIREMENTS

220V Single-Phase

Serious personal injury could occur if you connect the machine to the power source before you have completed the set up pro- cess. DO NOT connect the machine to the power source until instructed to do so.

Amperage Draw

The Model G0609 motor draws the following amps under maximum load:

Motor Draw at 220V

18 Amps

Circuit Requirements

We recommend using a dedicated circuit for this machine. You MUST connect your machine to a grounded circuit that is rated for the amperage given below. Never replace a circuit breaker on an existing circuit with one of higher amper- age without consulting a qualified electrician to ensure compliance with wiring codes. If you are unsure about the wiring codes in your area or you plan to connect your machine to a shared circuit, consult a qualified electrician.

220V Circuit

20 Amps

Plug/Receptacle Type

Grounding

In the event of an electrical short, grounding reduces the risk of electric shock. The grounding wire in the power cord must be properly connect- ed to the grounding prong on the plug; likewise, the outlet must be properly installed and ground- ed. All electrical connections must be made in accordance with local codes and ordinances.

Electrocution or fire could result if this machine is not grounded correctly or if your electrical con- figuration does not com- ply with local and state codes. Ensure compliance by checking with a quali- fied electrician!

Extension Cords

We do not recommend the use of extension cords. Instead, arrange the placement of your equipment and the installed wiring to eliminate the need for extension cords.

If you find it absolutely necessary to use an extension cord at 220V with your machine:

Use at least a 12 gauge cord that does not exceed 50 feet in length!

Recommended Plug/Receptacle....NEMA L6-20

 

Figure 2. NEMA L6-20 plug and receptacle. -10-

The extension cord must also contain a ground wire and plug pin.

A qualified electrician MUST size cords over 50 feet long to prevent motor damage.

G0609 12" Parallelogram Jointer

Image 12
Contents Model G0609 Parallelogram Jointer Page Table of Contents Warranty and Returns Introduction ForewordContact Info Machine Data Sheet Capacity Identification Safety G0609 12 Parallelogram JointerG0609 12 Parallelogram Jointer Additional Safety for Jointers 220V Single-Phase Circuit RequirementsSET UP Set Up SafetyItems Needed for Set Up UnpackingCrate Contents Qty InventoryHardware and Tools Qty Hardware Recognition Chart Clean Up Machine PlacementSite Considerations Floor LoadMoving & Placing Jointer Mounting to Shop FloorBolting to Concrete Floors To lift the jointerTo install the fence FenceFence is Heavy Pedestal Switch To set up the pedestal switchWinding Cutterhead Guard Components and Hardware Needed QtyKnife Setting Jig Checking Outfeed Table HeightTo check the outfeed table height Dust Port Test Run Recommended CFM at Dust Port ... CFMTo test run the machine Operation Safety Basic Controls OperationsStock Inspection and Requirements Correct and incorrect grain alignmentMinimum dimensions for edge Jointing Squaring StockSurface Planing To surface plane on the jointerEdge Jointing To edge joint on the jointerBevel Cutting To bevel cut on the jointerRabbet Cutting To rabbet cut on the jointerAccessories H9291-12 Shellix Spiral CutterheadG3631-Jointer/Planer Knife Hone H2404-Jointer PalMagnetic Knife Jig Up to 12 Carbide or HSSGrizzly Dial Calipers Our most popular safety glasses H1300 H1298 G7984 H2347 H0736Maintenance CleaningSchedule Unpainted Cast IronMaintenance Log Date Approximate Hours Of Use Maintenance PerformedService TroubleshootingMotor & Electrical Cutting Adjusting/Replacing Knives Inspecting KnivesTools Needed Qty To inspect the knivesCutterhead profile diagram To adjust/replace the knivesPage Checking/Adjusting Table Parallelism Checking Outfeed TableTo check the outfeed table parallelism Adjusting Table Parallelism To adjust the table parallelismChecking Infeed Table To check the infeed table parallelismSetting Outfeed Table Height To set the outfeed table heightSetting Infeed Table Setting Fence Stops Calibrating DepthScale To calibrate the depth scaleTo set the 90˚ fence stop To set the 45 outward fence stopBelts Pulley Alignment To replace the V-beltsTo align the pulleys Page G0609 Electrical Components Motor junction boxG0609 Wiring Diagram Base Assembly Parts Breakdown Base Parts List DescriptionTable Assembly Parts Breakdown Table Parts List Fence Assembly Parts Breakdown Fence Parts List Stand Assembly Parts Breakdown Stand Parts List 413 412 411 402403 401 410 404 405 406 409 407 408 Warranty and Returns Page Page