Grizzly G0609 owner manual To set the 90˚ fence stop, To set the 45 outward fence stop

Page 44

To set the 90˚ fence stop:

1.Lower the stop block against the fence, as shown in Figure 59, and loosen the fence tilt lock.

Stop Block

Jam Nut

Positive

Stop Bolt

Figure 59. Adjusting fence to 90˚.

2.Tilt the fence to the 90° position.

3.Using a 90° square, check the fence angle.

—If it is not set at exactly 90°, loosen the jam nut and adjust the positive stop bolt until the fence is exactly 90° as shown in Figure 59.

4.Tighten the jam nut.

To set the 45° outward fence stop:

1.Raise the stop block, loosen the fence tilt lock, and position the fence against the 45° outward positive stop bolt.

—If the fence is not set at exactly 45˚ out- ward, loosen the jam nut on the 45˚ out- ward fence positive stop bolt (Figure 60).

Positive Stop

Bolt

Jam

Nut

Figure 60. Adjusting fence 45˚ outward.

2. Adjust the 45˚ outward positive stop bolt until the fence is exactly 45° outward while rest- ing on the bolt (check the angle with a sliding bevel set to 135°).

3. Retighten the jam nut loosened in Step 2.

-42-

G0609 12" Parallelogram Jointer

Image 44
Contents Model G0609 Parallelogram Jointer Page Table of Contents Warranty and Returns Contact Info IntroductionForeword Machine Data Sheet Capacity Identification Safety G0609 12 Parallelogram JointerG0609 12 Parallelogram Jointer Additional Safety for Jointers 220V Single-Phase Circuit RequirementsSET UP Set Up SafetyItems Needed for Set Up UnpackingHardware and Tools Qty Crate Contents QtyInventory Hardware Recognition Chart Clean Up Machine PlacementSite Considerations Floor LoadMoving & Placing Jointer Mounting to Shop FloorBolting to Concrete Floors To lift the jointerFence is Heavy To install the fenceFence Pedestal Switch To set up the pedestal switchWinding Cutterhead Guard Components and Hardware Needed QtyTo check the outfeed table height Knife Setting JigChecking Outfeed Table Height To test run the machine Dust Port Test RunRecommended CFM at Dust Port ... CFM Operation Safety Basic Controls OperationsStock Inspection and Requirements Correct and incorrect grain alignmentMinimum dimensions for edge Jointing Squaring StockSurface Planing To surface plane on the jointerEdge Jointing To edge joint on the jointerBevel Cutting To bevel cut on the jointerRabbet Cutting To rabbet cut on the jointerAccessories H9291-12 Shellix Spiral CutterheadG3631-Jointer/Planer Knife Hone H2404-Jointer PalMagnetic Knife Jig Up to 12 Carbide or HSSGrizzly Dial Calipers Our most popular safety glasses H1300 H1298 G7984 H2347 H0736Maintenance CleaningSchedule Unpainted Cast IronMaintenance Log Date Approximate Hours Of Use Maintenance PerformedMotor & Electrical ServiceTroubleshooting Cutting Adjusting/Replacing Knives Inspecting KnivesTools Needed Qty To inspect the knivesCutterhead profile diagram To adjust/replace the knivesPage To check the outfeed table parallelism Checking/Adjusting Table ParallelismChecking Outfeed Table Adjusting Table Parallelism To adjust the table parallelismChecking Infeed Table To check the infeed table parallelismSetting Outfeed Table Height To set the outfeed table heightSetting Infeed Table Setting Fence Stops Calibrating DepthScale To calibrate the depth scaleTo set the 90˚ fence stop To set the 45 outward fence stopTo align the pulleys Belts Pulley AlignmentTo replace the V-belts Page G0609 Electrical Components Motor junction boxG0609 Wiring Diagram Base Assembly Parts Breakdown Base Parts List DescriptionTable Assembly Parts Breakdown Table Parts List Fence Assembly Parts Breakdown Fence Parts List Stand Assembly Parts Breakdown Stand Parts List 413 412 411 402403 401 410 404 405 406 409 407 408 Warranty and Returns Page Page