4-9. Arc Controls

1

2

1 Arc Control (Dig)

For AC And DC SMAW Welding

When set at 0, short-circuit amper- age at low arc voltage is the same as normal welding amperage.

When setting is increased, short- circuit amperage at low arc voltage increases.

Set at 0 for GTAW welding.

2 Arc Control Switch

Place switch in the ON position to turn on arc control circuitry. When switch is in the OFF position, no ad- ditional amperage is available at low arc voltages. Place switch in the OFF position while performing Gas Tungsten Arc Welding (GTAW).

Application:

Control helps arc starting or making vertical or overhead welds by in- creasing amperage at low arc volt- age, and reduces electrode sticking while welding.

4-10. Postflow Time Control

1 Postflow Time Control

Use control to set length of time (0–70 seconds) gas flows after welding stops. It is important to set enough time to allow gas to flow un-

1til after the tungsten and weld puddle has cooled down.

Application:

Postflow is required to cool tung- sten and weld, and to prevent con- tamination of tungsten and weld. In- crease postflow time if tungsten or weld are dark in appearance.

TM-353 Page 18

Syncrowave 250

Image 22
Contents SyncrowaveR Table of Contents Declaration of Conformity For European Community CE Products Page Marks a special safety message Safety Precautions for ServicingSymbol Usage Servicing HazardsEMF Information About Pacemakers+ + + DefinitionsISO/IEC Rating Label For CE ProductsSymbols And Definitions Some symbols are found only on CE productsVolt-Ampere Curves InstallationSpecifications 220 230 260 380 415 46060% Duty Cycle At 200 Amperes Duty Cycle And OverheatingOverheating Selecting a Location Dimensions And WeightsMovement Location And Airflow Weld Output Terminals And Selecting Cable Sizes Be careful when placing or moving unit over uneven surfacesTipping ARC Welding can cause Electromagnetic InterferenceVolts AC Duplex Receptacle And Shielding Gas Connections Turn Off power before connecting to receptacleRemote 14 Receptacle SocketElectrical Service Guide All values calculated at 60% duty cyclePlacing Jumper Links And Connecting Input Power Check label inside your unit- only one label is on unitOperation ControlsOutput Selector Switch MetersSpot Time Controls Crater Time ControlsApplication AC Balance Control Setting Output WaveformsBalance Control AC Gtaw Amperage Adjustment Controls Output Contactor Control SwitchPostflow Time Control Arc ControlsFor AC And DC Smaw Welding High Frequency Controls Preflow Time Control OptionalTheory of Operation SCRHD1 Troubleshooting Troubleshooting TableNecessary parts Dition of contacts. Replace CR5 if necessary Contacts. Replace CR2 if necessary Troubleshooting Circuit Diagram For Welding Power Source V24 See -1 forHD1 location D, EWaveforms For Section GndAC Output, 100 Amperes, 24 Volts AC Re- sistive Load Control Board PC1 Testing Information Use With Section Control Board PC1 Test Point Values Reference for gate pulse to SCR4 RC54 Not usedReceptacle Pin Value Remote Board PC2 Testing Information Use With Section RC3 Meter Calibration Input Voltage Labels And Connections Months MaintenanceRoutine Maintenance Circuit Breaker CB1Turn Off power before adjusting spark gaps Adjusting Spark GapsFuses F1 And F2 Sources Of HF Radiation From Incorrect Installation Welding Processes Using HFHigh Frequency HF Correct Installation Electrical Diagrams Model Serial Or Style Number Circuit Diagram Wiring DiagramSC-114 SC-120 SC-121 SC-124 SC-124 785-B SC-132 697-A SC-137 SC-135 SC-142 SC-148 SC-154 649-C SC-178 SC-179 303-A SC-181 109-E SC-188 161-A Syncrowave TM-353 TM-353 SD-188 162-A TM-353 SD-187 644 1 TM-353 SD-187 644 2 SA-121 SA-044 725-C TM-353 Description Parts List Main AssemblyPLG51 114 BASE, Prior to KE727074 170 Panel, Front w/Components Panel, Front w/ Components Rectifier, Si Diode -1 Item Panel, Mtg Components -1 Item Control Panel, Lower Front 126 Capacitor ASSEMBLY, Eff w/JK537589 thru JK690986 C14 124 COIL, HF coupling Eff w/JK572898 thru KF959378 174 Optional Equipment Page Miller