| a) Tolerance – ± 10% unless |
|
| PC2 Voltage Readings | specified |
|
| b) Reference – to circuit common | |
|
|
| |
|
|
| (lead 42) unless noted |
Receptacle | Pin | Value |
|
RC1 | A | 24 volts ac |
|
| B | Contact closure to A completes 24 volts ac contactor control circuit | |
| C | Command reference; 0 to +10 volts dc output to remote control | |
| D | Remote control circuit common |
|
| E | 0 to +10 volts dc input command signal from remote control |
|
| K | Chassis common |
|
RC2 | 1 | Command reference; 0 to +10 volts dc output to remote control | |
| 3 | Contact closure to A completes 24 volts ac contactor control circuit | |
| 4 | Remote control circuit common |
|
| 5 | 0 to +10 volts dc input command signal from remote control |
|
| 6 | 24 volts ac |
|
RC3
1
Chassis common
Syncrowave 250 |