Chapter 4 Maintenance and Upgrade Procedures for the ASA
Removing and Installing the Power Supply
Step 3 Grasp the SFP on both sides, and remove it from the port.
Removing and Installing the Power Supply
•Removing and Installing the AC Power Supply, page
•Installing the DC Input Power, page
•Removing and Installing the DC Power Supply, page
Removing and Installing the AC Power Supply
Caution If you remove a power supply, replace it immediately to prevent disruption of service.
Caution If the appliance is subjected to environmental overheating, it shuts down and you must manually power cycle it to turn it on again.
Warning This unit has more than one power supply connection; all connections must be removed completely to completely remove power from the unit. Statement 102
Warning This product relies on the building’s installation for
Note This procedure applies only to the appliances with a removable AC power supply (ASA
To remove and install the AC power supply, follow these steps:
Step 1 If you are adding an additional power supply, from the back of the appliance, push the lever on the slot cover to the left to release it, grasp the handle of the slot cover and pull it away from the chassis. (See Figure