Chapter 4 Maintenance and Upgrade Procedures for the ASA
Removing and Installing the Power Supply
Figure | Ground Wires |
3
2
1
333057
1
3
Negative | 2 Ground lead wire |
Positive (+) lead wire
Figure 4-24 shows the DC power supply with lead wires.
Figure 4-24 DC Power Supply with Lead Wires
333060
Step 7 Insert the exposed end of one of the ground wires into the inlet on the DC power supply. After you push in the wires, they are held in place with a spring, which makes the physical contact. Make sure that you cannot see any wire lead. Only wires with insulation should extend from the DC power supply.
Step 8 Repeat Step 5 through Step 7 for the remaining two DC input power source wires, the positive lead wire and the negative lead wire.