Cisco Systems quick start Verifying Power Supply Operation, Start the Cisco ASR 1004 Router

Page 20

Step 8 Connect the other ends of the terminal block cables to the site ground connection. Move the circuit-breaker switch to the On position ().

This completes the procedure for connecting DC-input power. Your installation is complete. Proceed to the “Start the System” section on page 14 to start the router.

Note After powering off the router, wait a minimum of 30 seconds before powering it on again.

Verifying Power Supply Operation

Follow this procedure to verify power supply is operating correctly.

Step 1 Check that the power supply LEDs are:

INPUT OK is green

FAN OK is green

OUTPUT FAILED is not illuminated

Step 2 To ensure that the power supply state is OK, type the show platform command. This output sample is from a Cisco ASR1004 router.

MCP_SCAL_R1#sho plat

Chassis type: ASR1004

The following output displays:

Slot

Type

State

Insert Time

0

ASR1000-SIP10

ok

00:03:19

1

ASR1000-SIP10

ok

00:03:19

RP0

ASR1000-RP1

ok,active

00:03:19

FP0

ASR1000-ESP20

ok,active

00:03:19

P0

ASR1004-PWR-AC

ok

00:02:50

P1

ASR1004-PWR-AC

ps, fail

00:02:50

Slot

CPLD Version

Firmware Version

0

07091401

12.2(33r)XN2

1

07091401

12.2(33r)XN2

RP0

08060301

12.2(0:0)

 

FP0

08041102

12.2(33r)XN2

MCP_SCAL_R1#

If the LEDs indicate a power problem or the power supply state is ps,fail, then contact a customer service representatives for assistance or additional instructions.

Start the Cisco ASR 1004 Router

After installing your Cisco ASR 1004 Router and connecting cables, start the router as follows.

Step 1 Check for the following:

20

Image 20
Contents Cisco ASR 1004 Router Documentation and Resources Document Revision HistoryPrepare for Installation Prepare for Equipment Shelf or Tabletop InstallationSite Preparation and Unpacking Tools and PartsAttach the Rack-Mount Brackets-Chassis Front-Mounted Prepare for Rack-Mount InstallationRack-Mount the Router Attach the Rack-Mount Brackets-Chassis Rear-Mounted Four-Post Rack Installation Installing the Cisco ASR 1004 Router in a Four-Post RackPage Two-Post Rack Installation Installing a Cisco ASR 1004 Router in a Two-Post RackAttach the Cable-Management Bracket Chassis Ground Connection Installation Chassis ground connector on the Cisco ASR 1004 Router Connect the Router to the Network Console and Auxiliary Port Cable ConnectionsCisco ASR1000-RP1 Enet Management Port Connector Management Ethernet Port Cable ConnectionInstall Cables in the Cable-Management Bracket Connect AC Power to the RouterStart the System Connect the Shared Port Adapter CablesConnect DC Power to the Router Cisco ASR 1004 Router AC Power SupplyUnit. Statement Installing the DC Ground Lugs Wiring the DC-Input Power Source Cisco ASR 1004 Router DC Power Supply Terminal Block Verifying Power Supply Operation Start the Cisco ASR 1004 RouterLED Page Page Configure Global Parameters Using the Setup Facility Configure the RouterUsing the Console Interface OK? No clns routing Tftptimeout Page Perform Other Configuration Tasks Check the Running Configuration SettingsSave the Running Configuration to Nvram Remove and Replace a Power Supply After InstallationPower Off the Cisco ASR 1004 Router Remove and Then Replace a DC Power Supply Page End View All measurements in inches 267 Holes Install and Remove the SPA Interface Processor SIP Remove the Shared Port Adapter ASR1000-SIP10Page USA