Sanyo KS1872 Shape the Indoor Side Tubing, Wiring Instructions General precautions on wiring

Page 10

3-5. Shape the Indoor Side Tubing

(1)Arrangement of tubing by direction

a)Right or left tubing

Cut out the corner of the right/left frame with a hacksaw or the like. (Figs. 20 and 21)

b)Right-rear or left-rear tubing

In this case, the corner of the frame need not be cut.

(2)To mount the indoor unit on the rear panel:

Hang the 2 mounting slots of the unit on the upper tabs of the rear panel. (Fig. 22)

3-6. Wiring Instructions

General precautions on wiring

(1)Before wiring, confirm the rated voltage of the unit as shown on its nameplate, then carry out the wiring closely following the wiring diagram.

(2)Provide a power outlet to be used exclusively for each unit, with a power supply disconnect and cir- cuit breaker for overcurrent protection provided in the exclusive line.

(3)To prevent possible hazards due to insulation failure, the unit must be grounded.

(4)Each wiring connection must be done tightly and in accordance with the wiring system diagram. Wrong wiring may cause the unit to misoperate or become damaged.

(5)Do not allow wiring to touch the refrigerant tubing, compressor, or any moving parts of the fan.

(6)Unauthorized changes in the internal wiring can be very dangerous. The manufacturer will accept no responsibility for any damage or misoperation that occurs as a result of such unauthorized changes.

Frame

Left tubing outlet

Fig. 20

Frame

Right tubing outlet

Fig. 21

Fig. 22

10

Image 10
Contents Installation Instructions Contents…In a Room For safe installation and trouble-free operation, you must…In a Ceiling or Wall …In Moist or Uneven LocationsGeneral Tools Required for Installation not suppliedAccessories Supplied with Unit Table Optional Copper Tubing KitAdditional Materials Required for Installation Installation Site SelectionIndoor Unit C1872, CL1872 Outdoor UnitC2472, CL2472 Baffle Plate for the Outdoor Unit CLxx models only Remove the Rear Panel from the Unit How to Install the Indoor UnitTrical wiring or conduits are Make a HoleIf Wooden Wall Install the Rear Panel on the WallIf Block, Brick, Concrete or Similar Type Wall How to remove the grille Remove the Grille to Install the Indoor UnitHow to replace the grille Wiring Instructions General precautions on wiring Shape the Indoor Side TubingRecommended Wire Length and Diameter AWGWiring Instructions for Inter-unit Connections For Outdoor Unit For solid core wiring or F-cable How to connect wiring to the terminal For Indoor UnitFor stranded wiring Mounting Right-side tubingDrain hose Switching drain hose and drain capLeft-side tubing Drain capTo unmount indoor unit Do not supply power toTubing and wiring to the out Unit or operate it until allHow to Install the Outdoor Unit Wiring Instructions for the Outdoor UnitRefrigerant Tubing Flaring Procedure with a Flare ToolUse of the Flaring Method Finishing the Installation Connecting Tubing between Indoor and Outdoor UnitsInsulation of Refrigerant Tubing Air Purging Be sure to completely insert Hex wrench beforeHow to Test Run the Air Conditioner Basic Functions of the Service Valves Pump DownTo take out the remote control unit, pull it forward Remote Control Unit Installation PositionMounting on a Wall Address Switch Address Setting of the Remote Control Unit