Sanyo KS1872 How to Install the Indoor Unit, Remove the Rear Panel from the Unit, Make a Hole

Page 7

3. How to Install the Indoor Unit

3-1. Remove the Rear Panel from the Unit

(1)Remove and discard the set screw on the rear panel. (Fig. 6)

(2)Press the 2 marks on the frame cover and disen- gage the stationary tabs from the frame. (Fig. 7)

(3)Remove the rear panel.

NOTE

Tubing can be extended in 5 directions as shown in Fig.

8.Select the direction you need providing the shortest run to the outside unit.

When left tubing is to be done, switch the drain hose and drain cap. (For details, refer to “Switching drain hose and drain cap” on page 14.)

3-2. Make a Hole

(1)Place the rear panel from the indoor unit on the wall at the location selected. Make sure the panel is hori- zontal, using a carpenter’s level or tape measure to measure down from the ceiling. Wait until after cut- ting the hole before attaching the rear panel to the wall.

(2)Determine which side of the unit you should make the hole for tubing and wiring. (Fig. 9)

NOTE

In the case of left-rear tubing, use the measurement points 2-3/8" (60 mm) from the edge of the rear panel for precise placement of the hose outlet. (Fig. 9)

(3)Before making the hole, check carefully that no studs or pipes are directly run behind the spot to be cut.

CAUTION

Also avoid areas where elec-

trical wiring or conduits are

 

 

located.

The above precautions are also applicable if tubing goes through the wall in any other location.

Set screw only for transportation

Fig. 6

Rear panel

marks

Fig. 7

Right-rear tubing

Left(recommended) tubing

Left-rear

 

tubing

Right tubing

 

Downward tubing

Fig. 8

2-3/8" (60 mm)

Fig. 9

7

Image 7
Contents Contents Installation Instructions…In Moist or Uneven Locations For safe installation and trouble-free operation, you must…In a Ceiling or Wall …In a RoomOptional Copper Tubing Kit Tools Required for Installation not suppliedAccessories Supplied with Unit Table GeneralAdditional Materials Required for Installation Installation Site SelectionIndoor Unit C1872, CL1872 Outdoor UnitC2472, CL2472 Baffle Plate for the Outdoor Unit CLxx models only Make a Hole How to Install the Indoor UnitTrical wiring or conduits are Remove the Rear Panel from the UnitIf Wooden Wall Install the Rear Panel on the WallIf Block, Brick, Concrete or Similar Type Wall How to remove the grille Remove the Grille to Install the Indoor UnitHow to replace the grille Shape the Indoor Side Tubing Wiring Instructions General precautions on wiringAWG Recommended Wire Length and DiameterWiring Instructions for Inter-unit Connections For Outdoor Unit For solid core wiring or F-cable How to connect wiring to the terminal For Indoor UnitFor stranded wiring Right-side tubing MountingDrain cap Switching drain hose and drain capLeft-side tubing Drain hoseUnit or operate it until all Do not supply power toTubing and wiring to the out To unmount indoor unitWiring Instructions for the Outdoor Unit How to Install the Outdoor UnitRefrigerant Tubing Flaring Procedure with a Flare ToolUse of the Flaring Method Finishing the Installation Connecting Tubing between Indoor and Outdoor UnitsInsulation of Refrigerant Tubing Air Purging Hex wrench before Be sure to completely insertHow to Test Run the Air Conditioner Pump Down Basic Functions of the Service ValvesTo take out the remote control unit, pull it forward Remote Control Unit Installation PositionMounting on a Wall Address Setting of the Remote Control Unit Address Switch