Sanyo KS1872 Remove the Grille to Install the Indoor Unit, How to remove the grille

Page 9

3-4. Remove the Grille to Install the Indoor Unit

Basically, these models can be installed and wired with- out removing the grille. If access to any internal part is needed, follow the steps as given below.

How to remove the grille

(1)Grasp both ends of the air intake grille, and remove it by opening towards the front and pulling towards you. (Fig. 16a)

(2)Remove the 3 screws. (Fig. 16b)

(3)Remove the screw on the right side cover plate and open the cover. (Fig. 17a)

(4)Take out the thermistor from the grille. (Fig. 17b)

(5)Press the 3 tabs at the top of the grille and the 3 tabs on the front face to separate the grille from the frame. (Fig. 18a)

(6)Pull the grill toward you to remove it.

How to replace the grille

(1)When installing the grille, place the bottom of the grille into the frame first. (Fig. 18b)

Then insert the tabs on the top of the grille and on the front face into the frame.

(2)Make sure that the grille and frame are firmly fitted together by engaging the tabs.

(3)Attach the thermistor on the grille. (Fig. 17a)

(4)Close the cover and replace the screw. (Fig. 17a)

(5)Affix the grille with the 3 previously removed screws. (Fig. 16b)

(6)Install the air intake grille.

(a)Allow the edge of the air intake grille to slide into the top of the indoor unit, and then insert it all the way inside. (Fig. 19a)

(b)Press the bottom right and left corners and center of the air intake grille to attach it to the indoor unit. (Fig. 19b)

NOTE

Attach so that the round pins at the top right and left cor- ners of the air intake grille are inserted into the grooves at the top right and left of the indoor unit.

Fig. 19b

Air intake grille

Grille

Fig. 16a

 

Fig. 16b

Thermistor

Cover

Thermistor

Fig. 17a

Fig. 17b

Tab

Tab

Fig. 18a

Fig. 18b

Groove

Pin

Fig. 19a

9

Image 9
Contents Contents Installation Instructions…In a Ceiling or Wall For safe installation and trouble-free operation, you must…In a Room …In Moist or Uneven LocationsAccessories Supplied with Unit Table Tools Required for Installation not suppliedGeneral Optional Copper Tubing KitInstallation Site Selection Additional Materials Required for InstallationIndoor Unit Outdoor Unit C1872, CL1872C2472, CL2472 Baffle Plate for the Outdoor Unit CLxx models only Trical wiring or conduits are How to Install the Indoor UnitRemove the Rear Panel from the Unit Make a HoleInstall the Rear Panel on the Wall If Wooden WallIf Block, Brick, Concrete or Similar Type Wall Remove the Grille to Install the Indoor Unit How to remove the grilleHow to replace the grille Shape the Indoor Side Tubing Wiring Instructions General precautions on wiringAWG Recommended Wire Length and DiameterWiring Instructions for Inter-unit Connections How to connect wiring to the terminal For Indoor Unit For Outdoor Unit For solid core wiring or F-cableFor stranded wiring Right-side tubing MountingLeft-side tubing Switching drain hose and drain capDrain hose Drain capTubing and wiring to the out Do not supply power toTo unmount indoor unit Unit or operate it until allWiring Instructions for the Outdoor Unit How to Install the Outdoor UnitFlaring Procedure with a Flare Tool Refrigerant TubingUse of the Flaring Method Connecting Tubing between Indoor and Outdoor Units Finishing the InstallationInsulation of Refrigerant Tubing Air Purging Hex wrench before Be sure to completely insertHow to Test Run the Air Conditioner Pump Down Basic Functions of the Service ValvesRemote Control Unit Installation Position To take out the remote control unit, pull it forwardMounting on a Wall Address Setting of the Remote Control Unit Address Switch