Sanyo KS1872 installation instructions Mounting, Right-side tubing

Page 14

3-9. Mounting

(1)To install the indoor unit, mount the indoor unit onto the 2 tabs on the upper part of the rear plate.

(2)Hold down the air discharge outlet and press the lower part of the indoor unit until it clicks to securely fasten to the 2 tabs on the lower part of the rear plate. (Fig. 33)

NOTE

For tubing, choose either the right or left tubing direction and follow the steps below. This work can be made easi- er by placing padding material (such as styrofoam) at the rear right side of the indoor unit. (Fig. 34)

Right-side tubing

(1)Shape the refrigerant tubing so that it can easily go into the wall hole. (Fig. 35)

(2)Push the wiring, refrigerant tubing, and drain hose through the hole in the wall. Adjust the indoor unit so it is securely seated on the rear panel. (Fig. 36)

(3)Carefully bend the tubing (if necessary) to run along the wall in the direction of the outdoor unit and then tape as far as the fittings. (See Caution on page 18.) The drain hose should come straight down the wall to a point where water runoff won’t stain the wall.

(4)Connect the refrigerant tubing to the outdoor unit. (After performing a leak test on the connecting part, insulate it with the tubing insulation. (Fig. 37a)) Also, refer to Section 5-4. Connecting Tubing between Indoor and Outdoor Units.

(5)Assemble the refrigerant tubing, drain hose, and conduit (including inter-unit wiring) as shown in Fig. 37b.

Refrigerant tubing

Insulation

Fig. 37a

Conduit

Drain hose

Inter-unit wiring

Fig. 37b

Push

Fig. 33

Padding material

Fig. 34

Rear panel

Cover

Refrigerant tubing

Inter-unit wiring

Drain hose

Fig. 35

Fig. 36

14

Image 14
Contents Installation Instructions Contents…In a Room For safe installation and trouble-free operation, you must…In a Ceiling or Wall …In Moist or Uneven LocationsGeneral Tools Required for Installation not suppliedAccessories Supplied with Unit Table Optional Copper Tubing KitIndoor Unit Installation Site SelectionAdditional Materials Required for Installation C2472, CL2472 Outdoor UnitC1872, CL1872 Baffle Plate for the Outdoor Unit CLxx models only Remove the Rear Panel from the Unit How to Install the Indoor UnitTrical wiring or conduits are Make a HoleIf Block, Brick, Concrete or Similar Type Wall Install the Rear Panel on the WallIf Wooden Wall How to replace the grille Remove the Grille to Install the Indoor UnitHow to remove the grille Wiring Instructions General precautions on wiring Shape the Indoor Side TubingRecommended Wire Length and Diameter AWGWiring Instructions for Inter-unit Connections For stranded wiring How to connect wiring to the terminal For Indoor UnitFor Outdoor Unit For solid core wiring or F-cable Mounting Right-side tubingDrain hose Switching drain hose and drain capLeft-side tubing Drain capTo unmount indoor unit Do not supply power toTubing and wiring to the out Unit or operate it until allHow to Install the Outdoor Unit Wiring Instructions for the Outdoor UnitUse of the Flaring Method Flaring Procedure with a Flare ToolRefrigerant Tubing Insulation of Refrigerant Tubing Connecting Tubing between Indoor and Outdoor UnitsFinishing the Installation Air Purging Be sure to completely insert Hex wrench beforeHow to Test Run the Air Conditioner Basic Functions of the Service Valves Pump DownMounting on a Wall Remote Control Unit Installation PositionTo take out the remote control unit, pull it forward Address Switch Address Setting of the Remote Control Unit