3.3 SYSTEM SETUP

Before using the HJZTP keyboard it must be set-up to meet the systems requirements. There are three aspects of the keyboards set-up which need to be set. These are keyboard type, DVR / multiplexer / camera connection, dome protocol.

Pressing and holding the ‘lock’ key and entering XXXX (code not shown) on the numeric keypad, will display the keyboard setup menu, as shown below:

A

U X

=

S E T

L

O C

K

=

E N

D

K

E Y

B R D

D V R /

M U

X

P R T C

L

‘KEYBRD’ will be flashing. Use the joystick left and right or the ‘F3’ (‘◄’) and ‘F4’ (‘►’) keys (or ‘camera’ and ‘preset’ buttons), to select the required option. Pressing ‘aux’ will then enter the required menu.

3.3.1Keyboard Type

The keyboard can be set as a master keyboard or one of 3 slave keyboards. The default setting is as a master keyboard.

If there is only one keyboard in the system or the keyboard is to be the one which is connected to the domes and DVRs / multiplexers, then the keyboard must be set as a master keyboard. Other keyboards in the system must be set as slaves. Up to three slave keyboards can be connected to the master keyboard, each slave keyboard must have a different slave keyboard number.

To set the keyboard type, select ‘KEYBRD’ in the keyboard setup menu. The following menu will be displayed:

A

U X

=

S E

T

L O C K

=

E

N D

M S T R

 

S L V

1

S L V 2

S L V

3

If the keyboard has not been set- up before ‘MSTR’ will be flashing, otherwise the keyboards current setting will be flashing. Use the joystick left and right or the ‘F3’ (‘’) and ‘F4’ (‘’) keys (or ‘camera’ and ‘preset’ keys) to select the required option, then press ‘aux’. The keyboard type selected will be displayed for 1 second to confirm the selection, as shown below (n is the Slave number):

S L A V E

n

K E Y B O A R D

Or:

M A S T E R K E Y B O A R D

Once the required keyboard type has been selected, press ‘lock’ to exit the menu.

Rev. 1.01

13

900.0570

 

 

8-Sept-05

Image 23
Contents HJZTP/HJZTPX 900.0570 Issue Date RevisionsHJZMU001150 European Compliance Statement Explanation of Graphical SymbolsFCC Compliance Statement Canadian Compliance Statement Important Safeguards Important Safeguards U T I O N Table of Contents Rev Viii 900.0570 Sept-05 PTZ Control Functions When Using Honeywell Maxpro Mode Hjztp Rear Panel List of FiguresCompatible Products Section IntroductionProduct Description Package Contents Connections Section InstallationConnector Function Supplied Cables Eight-Way RJ45 Connector to Eight-Way RJ45 ConnectorEight-Way RJ45 Connector to Green Wire and Blue Wire Daisy chain Dome ConnectionsDome Star Wiring Configuration Star Wiring ConfigurationDVR and Multiplexer Connection DVR SetupMultiplexer Setup Master/Slave Connection Keyboard CascadingSignal Usual colour Connector PIN AssignmentsPin Signal Usual colour Power C K E D Section SetupKeyboard Lock O T LCD DisplayA V E Y B O a R D System SetupT C C K T RC K 2 DVR/Multiplexer/Camera ConnectionCAM DVR MUX O C O L Dome PTZ ProtocolC K = DVR Menus DVR ModeNumber Entry for Entering Passwords Section DVR Control FunctionsDVR Selection Picture ControlCamera Selection Key Function User Level Required Recording and PlaybackSpot Function Alarm FunctionLive Multiplexer ModeSection Multiplexer Control Functions MenusPop Up Menu Bottom MenuFull 2x2 3x3 4x4 PIPLCD Auxiliary Monitor SelectionMultiplexer Selection PAN and Tilt PTZ ModePTZ Camera Selection Control WASH, Wipe and Auxiliary Functions Honeywell VCL ProtocolFocus and Iris To Seek a Preset Presets and ToursTo Define a Preset To Vary the Standard Speed of a Tour To Start a Tour of PresetsTo Define a Simple Tour To Vary the Standard Speeds and Dwell Times of a Tour C K O M Enhanced FunctionsV a C Y M E O F F Privacy Zones HomeU R M E T E M E OM E R a R E S E T Digital Zoom Remote ResetW E R U P R E S E T Factory Reset C T O R Y R E S E T Camera ResetO R M I C Rev 900.0570 Sept-05 PTZ Camera Selection Honeywell Diamond Protocol Preshot Definition Honeywell Diamond Protocol PAN and TiltFocus Flashback Honeywell Diamond Protocol Preshot SeekVectorscan Selection FreezeOn Screen Display OSD Menus Honeywell Diamond Protocol NightshotReturn to Manual Mechanical HomeX T G E Honeywell Diamond Protocol On Screen Display OSD MenusE W P R G G R a M S T= S E N D K = Flashback Operation IntroductionControlling Scan Assemblies Freeze / Unfreeze VideoPreprogrammed Preshots KD6/HD6 Maxpro ModePreshots Run VectorScan Vectorscans Video TourProgramming Sector IDS Programming Privacy ZonesPTZ Tour Operation Programming PTZ ToursHjztp / Hjztpx Section Technical SpecificationsRev 900.0570 Sept-05 Appendix a Menu Navigation Rev 900.0570 Sept-05 KEY Test Appendix B DiagnosticsJoystick Auto Calibration Rev 900.0570 Sept-05 Appendix C VCL ORBITER/RAPIDDOME Data Input Rev 900.0570 Sept-05 Appendix D Passwords Blankenbaker Pkwy, Suite Honeywell Video Systems Head Office