TECHNICAL SPECIFICATIONS

 

 

 

Features

HJZTP / HJZTPX

 

Max dome control

128

 

Max DVR control

8 x 16 way, 14 x 9 way, 32 x 4 way, 99 x 1 way (or any mixture up to 128 inputs)

Max multiplexer Control

8 x 16 way, 14 x 9 way, 32 x 4 way (or any mixture up to 128 inputs)

Compatible DVRs,

AHDR DVRs, HRHD DVRs, AXCD multiplexers, AXMD multiplexers,

multiplexers and domes

Orbiter/RapidDomes, KD6/HD6 domes

 

Max linked keyboards

1 master and 3 slaves

 

RS485 connections

1 half duplex and 2 full duplex

 

LCD

2 rows of 20 characters

 

DVR / multiplexer

DVRs

Multiplexers

functions controllable

Full screen picture cameras 1 to 16

Full screen picture cameras 1 to 16

via HJZTP

picture in picture

Picture in picture

 

 

2 x 2 picture

2 x 2 picture

 

3 x 3 picture

3 x 3 picture

 

4 x 4 picture

4 x 4 picture

 

Picture sequence, picture freeze,

Picture sequence

 

play, rewind, fast forward,

Picture freeze

 

stop, record, panic, spot

4 Spot monitors

 

Shuttle forwards/backwards

Zoom mode

 

Jog forwards/backwards

Tape input selection

 

Time / counter, alarm cancel

Menus

 

Event log menu, search menu,

 

 

main menu

 

Dome functions

Orbiter/RapidDome domes (VCL

KD6/HD6 domes (Diamond protocol)

controllable via HJZTP

protocol)

 

 

Variable speed pan / tilt via joystick

Variable speed pan / tilt via joystick

 

Zoom via twist joystick

Zoom via twist joystick

 

Focus near, focus far, auto focus

Focus near, focus far

 

Iris open, iris close, auto Iris

Iris open, iris close, auto Iris

 

Colour / mono change-over

99 presets (program and selection)

 

Auto 180 turn around

4 rapid preset selections ( 1 to 4)

 

128 presets (program and selection)

10 vectorscans (selection)

 

4 rapid preset selections ( 1 to 4)

Nightshot mode, freeze, flashback,

 

4 preset tours (program and selection)

home, return to manual

 

4 mimic tours (program and selection)

Full control of on screen menus to

 

Privacy zone programming

 

Home preset / tour programming

program presets, vectorscans, PTZ

 

tours, privacy zones, sectors, and also

 

Digital zoom, IR lamp, auto180 setup

 

control all camera setting and diagnostic

 

Power, camera and factory reset

 

options.

 

Wash, wipe, aux

 

 

Dimensions WxHxD

355mm x 180mm x 60mm

 

Weight (Approximate)

3.0kg

 

Power Supply Provided

12V DC regulated 300mA

 

Operating Temperature

0C to 40C

 

Rev. 1.01

45

900.0570

 

 

8-Sept-05

Image 55
Contents HJZTP/HJZTPX HJZMU001150 Issue Date Revisions900.0570 FCC Compliance Statement Canadian Compliance Statement Explanation of Graphical SymbolsEuropean Compliance Statement Important Safeguards Important Safeguards U T I O N Table of Contents Rev Viii 900.0570 Sept-05 PTZ Control Functions When Using Honeywell Maxpro Mode Hjztp Rear Panel List of FiguresProduct Description Section IntroductionCompatible Products Package Contents Connector Function Section InstallationConnections Eight-Way RJ45 Connector to Green Wire and Blue Wire Eight-Way RJ45 Connector to Eight-Way RJ45 ConnectorSupplied Cables Daisy chain Dome ConnectionsDome Star Wiring Configuration Star Wiring ConfigurationMultiplexer Setup DVR SetupDVR and Multiplexer Connection Master/Slave Connection Keyboard CascadingPin Signal Usual colour Connector PIN AssignmentsSignal Usual colour Power Keyboard Lock Section SetupC K E D O T LCD DisplayA V E Y B O a R D System SetupT C C K T RC K 2 DVR/Multiplexer/Camera ConnectionCAM DVR MUX C K = Dome PTZ ProtocolO C O L DVR Menus DVR ModeNumber Entry for Entering Passwords Section DVR Control FunctionsCamera Selection Picture ControlDVR Selection Key Function User Level Required Recording and PlaybackSpot Function Alarm FunctionLive Multiplexer ModeSection Multiplexer Control Functions MenusPop Up Menu Bottom MenuFull 2x2 3x3 4x4 PIPLCD Auxiliary Monitor SelectionMultiplexer Selection PTZ Camera Selection Control PTZ ModePAN and Tilt Focus and Iris Honeywell VCL ProtocolWASH, Wipe and Auxiliary Functions To Define a Preset Presets and ToursTo Seek a Preset To Define a Simple Tour To Start a Tour of PresetsTo Vary the Standard Speed of a Tour To Vary the Standard Speeds and Dwell Times of a Tour V a C Y Enhanced FunctionsC K O M M E O F F Privacy Zones HomeU R M E T E M E OM E R a R E S E T Digital Zoom Remote ResetW E R U P R E S E T Factory Reset C T O R Y R E S E T Camera ResetO R M I C Rev 900.0570 Sept-05 PTZ Camera Selection Honeywell Diamond Protocol Focus Honeywell Diamond Protocol PAN and TiltPreshot Definition Flashback Honeywell Diamond Protocol Preshot SeekVectorscan Selection FreezeOn Screen Display OSD Menus Honeywell Diamond Protocol NightshotReturn to Manual Mechanical HomeX T G E Honeywell Diamond Protocol On Screen Display OSD MenusE W P R G G R a M S T= S E N D K = Flashback Operation IntroductionControlling Scan Assemblies Freeze / Unfreeze VideoPreshots KD6/HD6 Maxpro ModePreprogrammed Preshots Run VectorScan Vectorscans Video TourProgramming Sector IDS Programming Privacy ZonesPTZ Tour Operation Programming PTZ ToursHjztp / Hjztpx Section Technical SpecificationsRev 900.0570 Sept-05 Appendix a Menu Navigation Rev 900.0570 Sept-05 Joystick Auto Calibration Appendix B DiagnosticsKEY Test Rev 900.0570 Sept-05 Appendix C VCL ORBITER/RAPIDDOME Data Input Rev 900.0570 Sept-05 Appendix D Passwords Blankenbaker Pkwy, Suite Honeywell Video Systems Head Office