HONEYWELL VCL PROTOCOL, CONTINUED
6.9.5To Vary the Standard Speed of a Tour, Continued
7.Press ‘2’, then press the ‘180°’ key. (This defines 2°/sec to this preset position.)
8.Release the ‘autopan’ key.
6.9.6To Vary the Standard Speed of a Tour, Continued
The tour is now set up. To operate ‘Tour 2’:
Press ‘2’, then press the ‘autopan’ key.
Note: The range of speeds that can be selected goes from ‘1’ = 1°/sec up to ‘100’ = 100°/sec. To select the maximum seek speed, press ‘0’.
6.9.7To Vary the Standard Speeds and Dwell Times of a Tour
For example to define a tour (as set in 6.1.7.4, above.) in memory as ‘Tour 3’ with different dwell times between preset positions:
1.Press ‘3’, then press and hold the ‘autopan’ key. (This will define ‘Tour 3’.)
2.Press ‘1’, then press the ‘preset’ key. (This selects the first preset in ‘Tour 3’.)
3.Press ‘5’, then press ‘0’, then press the ‘180°’ key. (This defines 50°/sec to this preset position.)
4.Press ‘1’, then press ‘0’, then press the ‘counter’ key. (This defines a 10 second dwell time at this preset position.)
5.Press ‘2’, then press the ‘preset’ key. (This selects the second preset in ‘Tour 3’.)
6.Press ‘1’, then press ‘0’, then press ‘0’, then press the ‘180°’ key. (This defines 100°/sec to this preset position.)
7.Press ‘1’, then press ‘6’, then press the ‘counter’ key. (This defines a 16 second dwell time at this preset position.)
8.Press ‘3’, then press the ‘preset’ key. (This selects the third preset in ‘Tour 3’.)
9.Press ‘2’, then press the ‘180°’ key. (This defines 2°/ sec to this preset position.)
10.Press ‘1’, then press ‘4’, then press the ‘counter’ key. (This defines a 14 second dwell time at this preset position.)
11.Release the ‘autopan’ key.
Rev. 1.01 | 29 | 900.0570 |
|
|