8.7 VECTORSCANS (VIDEO TOUR)
CAUTION: Continuous VectorScan operation for extended periods of time (> 8 hours) is not recommended. Continuous operation results in increased zoom lens failure and maintenance expense.
When using Maxpro mode VectorScans can be programmed using the setup menu accessed by the PreShot 90 command. Refer to Section 7.15 for programming VectorScans using the setup menus.
8.7.1Run VectorScan
VectorScans 1, 2, and 3 can be started using PreShot commands 87, 88, and 89.
Example: To start VectorScan 2, send a PreShot 88 command.
VectorScans 0 and 4 - 9 can be assigned to alarms or the default function.
When a scan receives a command to run a VectorScan, the scan goes to the first PreShot programmed in the VectorScan at maximum velocity (400°/second) for the programmed dwell time, then goes to the next PreShot in the VectorScan at the programmed velocity for the specified dwell time, etc. When a VectorScan is running continuously, the unit goes from the last PreShot to the first PreShot at the programmed velocity. The amount of time the scan takes to go to each PreShot depends on the programmed velocity and the distance to the next PreShot’s pan and tilt coordinates. The velocity is programmable between 1° to 400° per second.
8.7.2Stop a VectorScan
Take manual control (pan, tilt, zoom, focus, or iris) of the scan.
Send the scan to a PreShot.
Start a PTZ tour or a different VectorScan.
Execute any other command addressed to that HD6i.
8.8 PROGRAMMING SECTOR IDS
Sector IDs cannot be programmed when using Maxpro mode.
8.9 PROGRAMMING PRIVACY ZONES
Privacy zones cannot be programmed when using Maxpro mode.
Rev. 1.01 | 43 | 900.0570 |
|
|