Honeywell HJZTPX user manual = S E N D K =

Page 50

HONEYWELL DIAMOND PROTOCOL, CONTINUED

7.15 ON SCREEN DISPLAY (OSD) MENUS, CONTINUED

For ‘setup’, ‘preshot program’, ‘vectorscan program’ and ‘sector program’, the programming menu will be displayed as below:

A

U

X = S E N D

A

L

O C K =

E N D

< C

A M

S C R

O L L

P R E >

When in the programming menu, on the first display the letter ‘A’ will be flashing to indicate ‘A’ will be sent to the domes menu when the ‘aux’ key is pressed.

Press the ‘camera’ and ‘preset’ keys to scroll through all available characters.

Pressing the ‘counter’ key will jump the selection between upper case and lower case letters. If a symbol character is being displayed when the ‘counter’ key is pressed, the selection will jump to lower case ‘a’.

Press and hold ‘Fn’, then press ’counter’ to jump to symbol characters when letter characters are being displayed.

Press ‘monitor’ to send ‘BACKSPACE’ to the dome to delete the last character.

Press and hold ‘Fn’, then press ’monitor’ to send the space character. The space character is also the character between ‘Z’ and ‘a’ when scrolling through the characters.

Press the number keys to send numbers to the domes menu.

The following keys are also used to control the OSD menus:

Press the ‘F1’ (‘▲’), ’F2’ (‘▼’), ‘F3’ (‘◄’) and ‘F4’ (‘►’) keys to move around the menu pages.

Press ‘F5’ (‘enter’) to send ‘ENTER’ to the domes menu.

Press ‘F6’ (‘menu’) to send ‘ESC’ to the domes menu.

Press ‘wash’ to send ‘INSERT’ to the domes to insert a line (in a vectorscan programming menu).

Press ‘wipe’ to send ‘DELETE’ to the domes to delete a line (in a vectorscan programming menu).

Press ‘sequence’ to send ‘S’ to the dome (for saving settings).

Press ’aux’ in list menus, to display the next page of items (if available).

Press ‘lock’ to exit the OSD and LCD menus, and return the dome and keyboard to normal operation.

The keyboard will also shut down the menus if there has been no keyboard activity for over one minute

Rev. 1.01

40

900.0570

 

 

8-Sept-05

Image 50
Contents HJZTP/HJZTPX 900.0570 Issue Date RevisionsHJZMU001150 European Compliance Statement Explanation of Graphical SymbolsFCC Compliance Statement Canadian Compliance Statement Important Safeguards Important Safeguards U T I O N Table of Contents Rev Viii 900.0570 Sept-05 PTZ Control Functions When Using Honeywell Maxpro Mode List of Figures Hjztp Rear PanelCompatible Products Section IntroductionProduct Description Package Contents Connections Section InstallationConnector Function Supplied Cables Eight-Way RJ45 Connector to Eight-Way RJ45 ConnectorEight-Way RJ45 Connector to Green Wire and Blue Wire Dome Connections Daisy chainStar Wiring Configuration Dome Star Wiring ConfigurationDVR and Multiplexer Connection DVR SetupMultiplexer Setup Keyboard Cascading Master/Slave ConnectionSignal Usual colour Connector PIN AssignmentsPin Signal Usual colour Power C K E D Section SetupKeyboard Lock LCD Display O TC K T R System SetupT C A V E Y B O a R D2 DVR/Multiplexer/Camera Connection C KCAM DVR MUX O C O L Dome PTZ ProtocolC K = Section DVR Control Functions DVR ModeNumber Entry for Entering Passwords DVR MenusDVR Selection Picture ControlCamera Selection Recording and Playback Key Function User Level RequiredAlarm Function Spot FunctionMenus Multiplexer ModeSection Multiplexer Control Functions LivePIP Bottom MenuFull 2x2 3x3 4x4 Pop Up MenuAuxiliary Monitor Selection LCDMultiplexer Selection PAN and Tilt PTZ ModePTZ Camera Selection Control WASH, Wipe and Auxiliary Functions Honeywell VCL ProtocolFocus and Iris To Seek a Preset Presets and ToursTo Define a Preset To Vary the Standard Speed of a Tour To Start a Tour of PresetsTo Define a Simple Tour To Vary the Standard Speeds and Dwell Times of a Tour C K O M Enhanced FunctionsV a C Y M E T E M E O HomeU R M E O F F Privacy ZonesC T O R Y R E S E T Camera Reset Remote ResetW E R U P R E S E T Factory Reset M E R a R E S E T Digital ZoomO R M I C Rev 900.0570 Sept-05 PTZ Camera Selection Honeywell Diamond Protocol Preshot Definition Honeywell Diamond Protocol PAN and TiltFocus Freeze Honeywell Diamond Protocol Preshot SeekVectorscan Selection FlashbackMechanical Home Honeywell Diamond Protocol NightshotReturn to Manual On Screen Display OSD MenusG R a M S T Honeywell Diamond Protocol On Screen Display OSD MenusE W P R G X T G E= S E N D K = Freeze / Unfreeze Video IntroductionControlling Scan Assemblies Flashback OperationPreprogrammed Preshots KD6/HD6 Maxpro ModePreshots Programming Privacy Zones Vectorscans Video TourProgramming Sector IDS Run VectorScanProgramming PTZ Tours PTZ Tour OperationSection Technical Specifications Hjztp / HjztpxRev 900.0570 Sept-05 Appendix a Menu Navigation Rev 900.0570 Sept-05 KEY Test Appendix B DiagnosticsJoystick Auto Calibration Rev 900.0570 Sept-05 Appendix C VCL ORBITER/RAPIDDOME Data Input Rev 900.0570 Sept-05 Appendix D Passwords Honeywell Video Systems Head Office Blankenbaker Pkwy, Suite