Extron electronic MLC 62 IR D manual Front and Left Side Panels, MLC D Front Panels

Page 15

4.Wire and connect the MLC power supply (see “Connecting Power to the MLC,” later in this section). Connect all other power cords and turn on all the devices, including the MLC.

5.Connect a configuration cable from the computer to the MLC by doing either of the following:

Connect a USB A to mini B cable to the MLC USB configuration port and to a USB port on your computer (see “Configuring the MLC via the USB Port,” later in this section).

Connect an RS-232 cable to the provided 3-pole connector and connect it between the MLC Host/Config port and the computer serial port (see “Wiring the Host/Config Port,” later in this section).

6.Download and install the MLC Configuration Program (see “Installing the Configuration Software,” in the “Software-based Configuration” section).

7.Download or create drivers for the devices you will be connecting (see “Obtaining

Device Drivers” or “Configuring Using IR Learning” in the “Software-based Configuration” section).

8.Configure the MLC buttons and ports using the configuration program. (See the configuration program help file for these procedures. To access the help file, see “Installing the Configuration Software” in the “Software Configuration and Control” section.)

If you are configuring via the USB port, remove the USB cable when you are finished.

9.Test the system: press the MLC buttons, watch the display, and listen to the audio output to determine whether the connected devices are responding correctly (powering on and off, switching inputs, and so forth). If not, ensure all devices are plugged in and receiving power. Check the cabling and make needed adjustments.

10.Disconnect power from the MLC at the source and from all other devices in the system.

11.Mount the MLC to the mounting surface, following the appropriate procedure for your MLC model, discussed later in this section:

For MLC 62 D models, see “Mounting the MLC 62 D.”

For MLC 62 RS EU and MK models, see “Mounting the MLC 62 RS EU and the MLC 62 RS MK.”

For the MLC 64, see “Mounting the MLC 64 RS VC D.”

12.Restore power to the MLC and to the connected devices.

Front and Left Side Panels

MLC D Front Panels

The front panels of the MLC 62 RS D, the MLC 62 IR D, and MLC 64 models contain buttons and indicators that are visible and accessible after the MLC has been mounted. Other front panel controls and connectors are located behind the MLC wallplate and are not visible after mounting (see “Controls behind the wallplate,” later in this section).

MLC 60 Series MediaLink Controllers • Features, Installation, and Operation

9

Image 15
Contents MLC 60 Series Safety Instructions English FCC Class a Notice Software Commands Conventions Used in this GuideNotifications Contents MLC 60 Series MediaLink Controllers Contents About This Guide About the MLC 60 Series MediaLink ControllersMLC Models MLC 62 RS EU Faceplate alternatives FeaturesVolume adjustment Application Diagrams MLC Configuration Software Device DriversMLC 62 IR D Controlling a Projector Extron System RequirementsInstallation Overview Features Installation, OperationMLC D Front Panels Front and Left Side PanelsMLC 64 RS VC D front panel MLC 62 D front panelsControls behind the wallplate MLC 62 RS EU and MLC 62 RS MK Front and Side PanelsFront panel features Buttons MLC 60 Series D Models Rear Panels Rear Panel FeaturesPort B IR/S MLC 64 RS VC D Volume Control Module Rear Panel Rear Panel Features on MLC 62 RS EU and MLC 62 RS MK OnlyInstallation Removing and Replacing the FaceplatesRemoving and replacing an MLC D faceplate Removing the Faceplate MLC 60 Series D Models Replacing the MLC 64 volume control knob Removing and replacing the MLC 62 RS EU and MK faceplates Removing the MLC 64 Volume Control Module FaceplateReplacing the Faceplate MLC 62 RS EU Replacing ButtonsWiring for RS-232 Control RS Models Only Connecting to Port a RS-232Connecting to Port B IR/S Wiring the Relays Port RS Models Only Wiring for IR ControlMLC Wiring the Digital Input Port RS Models OnlyConnecting a Two-position Switch to the Digital Input Port Wiring the Host/Config PortConnecting Power to the MLC Wiring the Volume Control Module MLC 64 RS VC D OnlyConnecting a Power Supply to an MLC Configuring the MLC via the USB PortUSB Port Connection for MLC 62 RS EU and MLC 62 RS MK Page IR Learning on an MLC D Model IR LearningMounting the MLC 60 Series Controllers Mounting an MLC 62 DMounting an MLC 62 D to an electrical junction box Mounting an MLC 62 D to a Decora Mounting Bracket Mounting an MLC 62 D to a Decora Mounting BracketMounting an MLC 64 RS VC D to an electrical junction box Mounting the MLC 64 RS VC DMounting an MLC 64 D to a Two-gang Decora Mounting Bracket Mounting an MLC 64 RS VC D to a Decora Mounting BracketMounting the MLC 62 RS EU to an Electrical Box Mounting the MLC 62 RS EU and the MLC 62 RS MKMounting the MLC 62 RS MK to an External Electrical Box Mounting the MLC EU in a Raceway Using Spacers OptionalMounting the MLC 62 RS EU Using a Spacer Accessing the Covered MLC D Front Panel Features Accessing Covered Panel Features After MountingFront Panel Security Lockout Locking Using the Front Panel ButtonsResetting the MLC Using the Reset Button Resetting to the default configurationResetting to the factory firmware defaults Computer System Requirements About the MLC Configuration ProgramInstalling the Configuration Software Downloading and Installing the Software from the WebInstalling the Software from the DVD Start Options Window Starting the Configuration SoftwareAdd Device Window with Select Model Menu Displayed Accessing the Help File Obtaining Device Drivers Downloading Drivers Using the Configuration ProgramDriver Subscription Window Driver Subscription Download Screen Drivers Tab and Button on the Software DVD Opening Screen Downloading Drivers from the DiscTo download the driver package MLC 60 Device Drivers Page on DVDSaving a Single Driver to the Computer To download a single driverDownloading Drivers from the Web Entering MLC 60 Series Driver Search Criteria Error Responses Host-to-Controller CommunicationsController-initiated Messages Symbol Definitions Using the Command and Response TableX2# X2% MLC 60 Series MediaLink Controllers SIS Control Command and Response Table for SIS Commands Command Ascii Command Response Additional DescriptionButton Selection Device Naming Front Panel Lockout Executive ModeRelay Functions RS models only Digital Input Data Port RS models onlyInformation Requests Reset/Erase= Button row 4, second LED = Button row 4, third LED Query LED statusMLC 62 Series Specifications SpecificationsGeneral Control digital input monitoring port RS modelsMLC 62 RS EU EMI/EMC MLC 64 RS VC D Specifications MLC 64 RS D Warranty Part Numbers and Accessories Included Parts Replacement Part NumberIncluded Parts MLC 62 RS EU MLC 64 RS VC D Accessories Part Number For Model AccessoriesEurope USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East
Related manuals
Manual 4 pages 23.22 Kb