Extron electronic MLC 62 IR D manual Features, Faceplate alternatives

Page 9

The five MLC models have the same button functionality and use the same configuration software. All models can be controlled by pressing the front panel buttons or via a host device using RS‑232 communication and simple ASCII commands (Simple Instruction Set, SIS). They differ from each other in the following ways:

The MLC 62 IR D rear panel does not contain the Relay, Digital Input, or RS-232 control ports that the RS models have.

The MLC 64 front panel has seven buttons, one of which (the Mute button) is located below the Volume knob. This button is used only to mute and unmute the volume on an Extron amplifier and cannot be configured to perform other functions.

Some front, side, and rear panel connectors are located in different places on the

MLC RS D (US), EU (Europe), and MK (United Kingdom) models (see “Panels and Connectors” in the “Features, Cabling, and Operation” section).

Faceplate alternatives

The MLC 60 Series models are available with the following faceplate configurations:

MLC 62 IR D: The US IR model is delivered with two six-button faceplates in black and white. One black and one white Decora wallplate are also provided. An eight-button faceplate is available to order.

MLC 62 RS D: The US RS-232 model is delivered with two eight-button faceplates in black and white. One black and one white Decora wallplate are also provided. A six-button faceplate is available to order.

MLC 62 RS EU: The European model is delivered with six-button and eight-button faceplates, both in RAL9010 white.

MLC 62 RS MK: The UK model is delivered with six-button and eight-button faceplates, both in white.

MLC 64 RS VC D: The MLC 64 is delivered with seven-button faceplates in black and white.

Features

Some of the features of MLC 60 Series include:

Customizable buttons — Eight buttons are standard on the MLC 62 RS models, prelabeled as shown in figure 1 on the previous page. The MLC 62 IR D has six prelabeled buttons, and the MLC 64 RS VC D has seven.

An additional set of prelabeled buttons is included with each model, enabling the controller to be customized to suit the application.

Additional buttons are available to order for all models, labeled in English (the default) and other languages. Buttons can be ordered with custom labeling as well.

Button backlighting — The front panel buttons are backlit to facilitate use in low-light environments and to provide certain status (such as whether power is on or off, or which input has been selected).

Alternative six-button configuration (MLC 62 RS models only) — For applications in which input device or button functions are not necessary, the standard eight-button faceplate on the MLC 62 RS can be replaced with a six-button one. Each pair of source selection buttons can be changed to a long, single function button.

Device drivers — A wide variety of Extron certified, ready-to-use device drivers are available via the MLC configuration software, the provided MLC software disk, and the Extron website (www.extron.com).

MLC 60 Series MediaLink Controllers • Introduction

3

Image 9
Contents MLC 60 Series Safety Instructions English FCC Class a Notice Software Commands Conventions Used in this GuideNotifications Contents MLC 60 Series MediaLink Controllers Contents About This Guide About the MLC 60 Series MediaLink ControllersMLC Models MLC 62 RS EU Faceplate alternatives FeaturesVolume adjustment Application Diagrams MLC Configuration Software Device DriversMLC 62 IR D Controlling a Projector Extron System RequirementsInstallation Overview Features Installation, OperationMLC D Front Panels Front and Left Side PanelsMLC 64 RS VC D front panel MLC 62 D front panelsControls behind the wallplate MLC 62 RS EU and MLC 62 RS MK Front and Side PanelsFront panel features Buttons MLC 60 Series D Models Rear Panels Rear Panel FeaturesPort B IR/S MLC 64 RS VC D Volume Control Module Rear Panel Rear Panel Features on MLC 62 RS EU and MLC 62 RS MK OnlyInstallation Removing and Replacing the FaceplatesRemoving and replacing an MLC D faceplate Removing the Faceplate MLC 60 Series D Models Replacing the MLC 64 volume control knob Removing and replacing the MLC 62 RS EU and MK faceplates Removing the MLC 64 Volume Control Module FaceplateReplacing the Faceplate MLC 62 RS EU Replacing ButtonsWiring for RS-232 Control RS Models Only Connecting to Port a RS-232Connecting to Port B IR/S Wiring the Relays Port RS Models Only Wiring for IR ControlMLC Wiring the Digital Input Port RS Models OnlyConnecting a Two-position Switch to the Digital Input Port Wiring the Host/Config PortConnecting Power to the MLC Wiring the Volume Control Module MLC 64 RS VC D OnlyConnecting a Power Supply to an MLC Configuring the MLC via the USB PortUSB Port Connection for MLC 62 RS EU and MLC 62 RS MK Page IR Learning on an MLC D Model IR LearningMounting the MLC 60 Series Controllers Mounting an MLC 62 DMounting an MLC 62 D to an electrical junction box Mounting an MLC 62 D to a Decora Mounting Bracket Mounting an MLC 62 D to a Decora Mounting BracketMounting an MLC 64 RS VC D to an electrical junction box Mounting the MLC 64 RS VC DMounting an MLC 64 D to a Two-gang Decora Mounting Bracket Mounting an MLC 64 RS VC D to a Decora Mounting BracketMounting the MLC 62 RS EU to an Electrical Box Mounting the MLC 62 RS EU and the MLC 62 RS MKMounting the MLC 62 RS MK to an External Electrical Box Mounting the MLC EU in a Raceway Using Spacers OptionalMounting the MLC 62 RS EU Using a Spacer Accessing the Covered MLC D Front Panel Features Accessing Covered Panel Features After MountingFront Panel Security Lockout Locking Using the Front Panel ButtonsResetting the MLC Using the Reset Button Resetting to the default configurationResetting to the factory firmware defaults Computer System Requirements About the MLC Configuration ProgramInstalling the Configuration Software Downloading and Installing the Software from the WebInstalling the Software from the DVD Start Options Window Starting the Configuration SoftwareAdd Device Window with Select Model Menu Displayed Accessing the Help File Obtaining Device Drivers Downloading Drivers Using the Configuration ProgramDriver Subscription Window Driver Subscription Download Screen Drivers Tab and Button on the Software DVD Opening Screen Downloading Drivers from the DiscTo download the driver package MLC 60 Device Drivers Page on DVDSaving a Single Driver to the Computer To download a single driverDownloading Drivers from the Web Entering MLC 60 Series Driver Search Criteria Error Responses Host-to-Controller CommunicationsController-initiated Messages Symbol Definitions Using the Command and Response TableX2# X2% MLC 60 Series MediaLink Controllers SIS Control Command and Response Table for SIS Commands Command Ascii Command Response Additional DescriptionButton Selection Relay Functions RS models only Front Panel Lockout Executive ModeDigital Input Data Port RS models only Device NamingInformation Requests Reset/Erase= Button row 4, second LED = Button row 4, third LED Query LED statusMLC 62 Series Specifications SpecificationsGeneral Control digital input monitoring port RS modelsMLC 62 RS EU EMI/EMC MLC 64 RS VC D Specifications MLC 64 RS D Warranty Part Numbers and Accessories Included Parts Replacement Part NumberIncluded Parts MLC 62 RS EU MLC 64 RS VC D Accessories Part Number For Model AccessoriesEurope, Africa, and the Middle China East USA, Canada, South America Japan Central AmericaAsia Middle East Europe
Related manuals
Manual 4 pages 23.22 Kb