Extron electronic MLC 62 IR D manual Wiring the Host/Config Port

Page 31

Example: The diagram below shows a two-position switch connected to the Digital Input port of an MLC 62 RS D.

Two-position Switch

GROUND

Rx

Tx

GROUND 1

HOST/

CONFIG

DIGITAL

INPUT

Pin:

Ground ( )

2

1

Digital Input 1

1

RELAYS

COMMON

 

MLC RS D Rear Panel

2

N/O

 

Figure 26. Connecting a Two-position Switch to the Digital Input Port

Wiring the Host/Config Port

The Host/Config port provides an alternative connection by which the MLC can be configured and controlled from a host device or computer. (The primary means of configuring the MLC is through the USB port; see “Configuring the MLC via the USB Port,” later in this section.) In addition, SIS commands can be issued through this port from the computer to control the MLC (see the “SIS Control” section).

The RS-232 protocol for this connection is 9600 baud, 1 stop bit, no parity, 8 data bits, no flow control.

Use a female 9-pin to bare wire RS-232 cable or a universal control cable (such as

UC 50', Extron part number 26-518-01, or UC 100', part number 26-518-02) to connect a Windows-based PC or an RS-232 control system to the MLC via this 3-pole, 3.5 mm captive screw connector as follows:

1.Wire the RS-232 cable to one of the 3-pole captive screw plugs provided with the

MLC, as follows:

Receive wire to pin 1, which plugs into the Tx (transmit) port

Transmit wire to pin 2, which plugs into the Rx (receive) port

Ground wire to pin 3, which plugs into the _ (ground) port

 

HOST/ CONFIG

Pin:

Tx

3

GROUND

 

Rx

 

2

 

DIGITAL INPUT

1

1

 

GROUND

 

 

1

RELAYS N/O

 

COMMON

 

 

2

 

 

GROUND

S

 

Tx/IR

IR/

 

MLC 62 RS D Rear Panel

GROUND

232-RS

 

Tx

PWR 12V MAXA0.2

 

GROUND

 

+12 VDC

 

 

Ground

Rx Receive

Tx Transmit

Ground ( ) 5

Transmit (Tx) 3

Receive (Rx) 2

9 pin HD

Connector

5 1

9 6

To RS-232 Port on Computer or Control System

Figure 27. Connecting a Host Computer or Control System to the Host/Config Port

2.Plug the 3-pole connector into the Host/Config port on the MLC rear panel.

MLC 60 Series MediaLink Controllers • Features, Installation, and Operation

25

Image 31
Contents MLC 60 Series Safety Instructions English FCC Class a Notice Conventions Used in this Guide Software CommandsNotifications Contents MLC 60 Series MediaLink Controllers Contents About the MLC 60 Series MediaLink Controllers About This GuideMLC Models MLC 62 RS EU Faceplate alternatives FeaturesVolume adjustment Application Diagrams MLC Configuration Software Device DriversMLC 62 IR D Controlling a Projector Extron System RequirementsInstallation Overview Features Installation, OperationMLC D Front Panels Front and Left Side PanelsMLC 64 RS VC D front panel MLC 62 D front panelsControls behind the wallplate MLC 62 RS EU and MLC 62 RS MK Front and Side PanelsFront panel features Buttons MLC 60 Series D Models Rear Panels Rear Panel FeaturesPort B IR/S MLC 64 RS VC D Volume Control Module Rear Panel Rear Panel Features on MLC 62 RS EU and MLC 62 RS MK OnlyRemoving and Replacing the Faceplates InstallationRemoving and replacing an MLC D faceplate Removing the Faceplate MLC 60 Series D Models Replacing the MLC 64 volume control knob Removing and replacing the MLC 62 RS EU and MK faceplates Removing the MLC 64 Volume Control Module FaceplateReplacing the Faceplate MLC 62 RS EU Replacing Buttons Connecting to Port a RS-232 Wiring for RS-232 Control RS Models Only Connecting to Port B IR/S Wiring the Relays Port RS Models Only Wiring for IR ControlMLC Wiring the Digital Input Port RS Models OnlyConnecting a Two-position Switch to the Digital Input Port Wiring the Host/Config PortConnecting Power to the MLC Wiring the Volume Control Module MLC 64 RS VC D OnlyConnecting a Power Supply to an MLC Configuring the MLC via the USB PortUSB Port Connection for MLC 62 RS EU and MLC 62 RS MK Page IR Learning on an MLC D Model IR LearningMounting an MLC 62 D Mounting the MLC 60 Series ControllersMounting an MLC 62 D to an electrical junction box Mounting an MLC 62 D to a Decora Mounting Bracket Mounting an MLC 62 D to a Decora Mounting BracketMounting an MLC 64 RS VC D to an electrical junction box Mounting the MLC 64 RS VC DMounting an MLC 64 D to a Two-gang Decora Mounting Bracket Mounting an MLC 64 RS VC D to a Decora Mounting BracketMounting the MLC 62 RS EU to an Electrical Box Mounting the MLC 62 RS EU and the MLC 62 RS MKMounting the MLC 62 RS MK to an External Electrical Box Mounting the MLC EU in a Raceway Using Spacers OptionalMounting the MLC 62 RS EU Using a Spacer Accessing the Covered MLC D Front Panel Features Accessing Covered Panel Features After MountingFront Panel Security Lockout Locking Using the Front Panel ButtonsResetting to the default configuration Resetting the MLC Using the Reset ButtonResetting to the factory firmware defaults Computer System Requirements About the MLC Configuration ProgramDownloading and Installing the Software from the Web Installing the Configuration SoftwareInstalling the Software from the DVD Start Options Window Starting the Configuration SoftwareAdd Device Window with Select Model Menu Displayed Accessing the Help File Obtaining Device Drivers Downloading Drivers Using the Configuration ProgramDriver Subscription Window Driver Subscription Download Screen Drivers Tab and Button on the Software DVD Opening Screen Downloading Drivers from the DiscTo download the driver package MLC 60 Device Drivers Page on DVDSaving a Single Driver to the Computer To download a single driverDownloading Drivers from the Web Entering MLC 60 Series Driver Search Criteria Host-to-Controller Communications Error ResponsesController-initiated Messages Symbol Definitions Using the Command and Response TableX2# X2% MLC 60 Series MediaLink Controllers SIS Control Command Ascii Command Response Additional Description Command and Response Table for SIS CommandsButton Selection Device Naming Front Panel Lockout Executive ModeRelay Functions RS models only Digital Input Data Port RS models onlyInformation Requests Reset/Erase= Button row 4, second LED = Button row 4, third LED Query LED statusMLC 62 Series Specifications SpecificationsGeneral Control digital input monitoring port RS modelsMLC 62 RS EU EMI/EMC MLC 64 RS VC D Specifications MLC 64 RS D Warranty Included Parts Replacement Part Number Part Numbers and AccessoriesIncluded Parts MLC 62 RS EU MLC 64 RS VC D Accessories Part Number For Model AccessoriesEurope USA, Canada, South America Japan Central AmericaEurope, Africa, and the Middle China East Asia Middle East